001005798 001__ 1005798
001005798 005__ 20230419201822.0
001005798 0247_ $$2doi$$a10.1520/STP164220210105
001005798 037__ $$aFZJ-2023-01643
001005798 041__ $$aEnglish
001005798 1001_ $$0P:(DE-Juel1)177067$$aDe Lannoye, Karen$$b0
001005798 1112_ $$aASTM 42nd Symposium on Obtaining Data for Fire Growth Models$$conline$$d2021-12-14 - 2021-12-15
001005798 245__ $$aComparison of Black and Transparent PMMA in the Cone Calorimeter
001005798 260__ $$a100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959$$bASTM International$$c2023
001005798 29510 $$aObtaining Data for Fire Growth Models
001005798 300__ $$a150 - 160
001005798 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$mcontrib
001005798 3367_ $$2ORCID$$aBOOK_CHAPTER
001005798 3367_ $$07$$2EndNote$$aBook Section
001005798 3367_ $$2DRIVER$$abookPart
001005798 3367_ $$2BibTeX$$aINBOOK
001005798 3367_ $$2DataCite$$aOutput Types/Book chapter
001005798 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book$$bcontb$$mcontb$$s1681878471_525
001005798 520__ $$aThe cone calorimeter is one of the standard devices used to assess the flammability of polymers. Several publications have been made studying different types of polymers and different set-ups in this apparatus. Polymers come in different forms and colors. It is unknown, however, whether the color of a polymer influences its burning behavior in the cone calorimeter. The color of a sample influences the amount of absorbed and reemitted thermal radiation, emitted by the cone calorimeter. This contribution presents the effect of different sample colors by performing cone calorimeter experiments with both transparent and black polymethyl methacrylate (PMMA) plates. Experiments were performed for four different heat fluxes: 25 kW/m², 35kW/m², 50kW/m², and 75 kW/m². All tests were autoignition experiments and 6-mm-thick PMMA plates were used. The effect of sample color on autoignition time, heat release rate, and mass loss data as well as oxygen (O2), carbon monoxide (CO), and carbon dioxide (CO2) production was assessed. Black PMMA showed a higher heat release rate (HRR) in the beginning of the tests, whereas transparent PMMA has a higher peak HRR. The color of the samples does not seem to influence the ignition time.
001005798 536__ $$0G:(DE-HGF)POF4-5111$$a5111 - Domain-Specific Simulation & Data Life Cycle Labs (SDLs) and Research Groups (POF4-511)$$cPOF4-511$$fPOF IV$$x0
001005798 588__ $$aDataset connected to CrossRef Book
001005798 7001_ $$0P:(DE-Juel1)138417$$aBelt, Alexander$$b1
001005798 7001_ $$0P:(DE-Juel1)130400$$aReinecke, Ernst-Arndt$$b2
001005798 7001_ $$00000-0002-1396-2810$$aMarkert, Frank$$b3
001005798 7001_ $$0P:(DE-Juel1)132044$$aArnold, Lukas$$b4$$eCorresponding author
001005798 773__ $$a10.1520/STP164220210105
001005798 8564_ $$uhttps://www.astm.org/stp164220210105.html
001005798 8564_ $$uhttps://juser.fz-juelich.de/record/1005798/files/2021-0105_DE%20LANNOYE.pdf$$yRestricted
001005798 909CO $$ooai:juser.fz-juelich.de:1005798$$pVDB
001005798 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)177067$$aForschungszentrum Jülich$$b0$$kFZJ
001005798 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)138417$$aForschungszentrum Jülich$$b1$$kFZJ
001005798 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130400$$aForschungszentrum Jülich$$b2$$kFZJ
001005798 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)132044$$aForschungszentrum Jülich$$b4$$kFZJ
001005798 9131_ $$0G:(DE-HGF)POF4-511$$1G:(DE-HGF)POF4-510$$2G:(DE-HGF)POF4-500$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-5111$$aDE-HGF$$bKey Technologies$$lEngineering Digital Futures – Supercomputing, Data Management and Information Security for Knowledge and Action$$vEnabling Computational- & Data-Intensive Science and Engineering$$x0
001005798 9141_ $$y2023
001005798 920__ $$lyes
001005798 9201_ $$0I:(DE-Juel1)IAS-7-20180321$$kIAS-7$$lZivile Sicherheitsforschung$$x0
001005798 980__ $$acontb
001005798 980__ $$aVDB
001005798 980__ $$acontrib
001005798 980__ $$aI:(DE-Juel1)IAS-7-20180321
001005798 980__ $$aUNRESTRICTED