001007384 001__ 1007384
001007384 005__ 20240712112912.0
001007384 0247_ $$2doi$$a10.1016/j.segy.2023.100104
001007384 0247_ $$2Handle$$a2128/34396
001007384 0247_ $$2WOS$$aWOS:001040904800001
001007384 037__ $$aFZJ-2023-02049
001007384 041__ $$aEnglish
001007384 082__ $$a333.7
001007384 1001_ $$0P:(DE-Juel1)179375$$aStock, Jan$$b0$$eCorresponding author
001007384 245__ $$aModelling of waste heat integration into an existing district heating network operating at different supply temperatures
001007384 260__ $$aAmsterdam$$bElsevier$$c2023
001007384 3367_ $$2DRIVER$$aarticle
001007384 3367_ $$2DataCite$$aOutput Types/Journal article
001007384 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1683719804_26067
001007384 3367_ $$2BibTeX$$aARTICLE
001007384 3367_ $$2ORCID$$aJOURNAL_ARTICLE
001007384 3367_ $$00$$2EndNote$$aJournal Article
001007384 520__ $$aA promising way to make use of waste heat sources is to distribute the heat to nearby buildings via district heating systems to cover the heat demands of the buildings. The integration of a waste heat source into an existing district heating system must be studied in advance to avoid difficulties in network operation and to ensure the required heat supply to all connected buildings. Simultaneously, supply temperature reduction can improve the overall system efficiency and should also be considered for a sustainable transformation of existing district heating systems.In this paper, we develop a district heating model with multiple supplying heat sources to study the influence of an additional integrated heat source and the effects of reduced supply temperatures on the network conditions. With the developed model, we investigate the waste heat integration into an existing district heating system at a German research facility campus. Therefore, we test different integrated waste heat shares to identify arising bottlenecks and to check for the sufficient heat supply to the connected consumers. Furthermore, we test the opportunity to additionally lowering the supply temperatures in the district heating network. The simulation results show that waste heat integration is possible at the investigated district heating system up to 40%. However, simultaneously lowering the supply temperature leads to greater challenges as more bottlenecks arise and additional buildings are affected by insufficient supply.
001007384 536__ $$0G:(DE-HGF)POF4-1122$$a1122 - Design, Operation and Digitalization of the Future Energy Grids (POF4-112)$$cPOF4-112$$fPOF IV$$x0
001007384 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
001007384 7001_ $$0P:(DE-Juel1)195821$$aArjuna, Felix$$b1
001007384 7001_ $$0P:(DE-Juel1)8457$$aXhonneux, André$$b2$$ufzj
001007384 7001_ $$0P:(DE-Juel1)172026$$aMüller, Dirk$$b3$$ufzj
001007384 773__ $$0PERI:(DE-600)3063943-8$$a10.1016/j.segy.2023.100104$$gVol. 10, p. 100104 -$$p1-13$$tSmart energy$$v10$$x2666-9552$$y2023
001007384 8564_ $$uhttps://juser.fz-juelich.de/record/1007384/files/1-s2.0-S2666955223000114-main.pdf$$yOpenAccess
001007384 909CO $$ooai:juser.fz-juelich.de:1007384$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
001007384 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)179375$$aForschungszentrum Jülich$$b0$$kFZJ
001007384 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)8457$$aForschungszentrum Jülich$$b2$$kFZJ
001007384 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)172026$$aForschungszentrum Jülich$$b3$$kFZJ
001007384 9131_ $$0G:(DE-HGF)POF4-112$$1G:(DE-HGF)POF4-110$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1122$$aDE-HGF$$bForschungsbereich Energie$$lEnergiesystemdesign (ESD)$$vDigitalisierung und Systemtechnik$$x0
001007384 9141_ $$y2023
001007384 915__ $$0LIC:(DE-HGF)CCBYNCND4$$2HGFVOC$$aCreative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0
001007384 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2021-05-28T12:09:26Z
001007384 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2021-05-28T12:09:26Z
001007384 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
001007384 915__ $$0StatID:(DE-HGF)0561$$2StatID$$aArticle Processing Charges$$d2022-11-19
001007384 915__ $$0StatID:(DE-HGF)0700$$2StatID$$aFees$$d2022-11-19
001007384 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2023-08-19
001007384 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bDOAJ : Anonymous peer review$$d2021-05-28T12:09:26Z
001007384 920__ $$lyes
001007384 9201_ $$0I:(DE-Juel1)IEK-10-20170217$$kIEK-10$$lModellierung von Energiesystemen$$x0
001007384 9801_ $$aFullTexts
001007384 980__ $$ajournal
001007384 980__ $$aVDB
001007384 980__ $$aUNRESTRICTED
001007384 980__ $$aI:(DE-Juel1)IEK-10-20170217
001007384 981__ $$aI:(DE-Juel1)ICE-1-20170217