001     1008321
005     20240712084507.0
024 7 _ |a 10.1051/epjpv/2023009
|2 doi
024 7 _ |a 10.34734/FZJ-2023-02283
|2 datacite_doi
024 7 _ |a WOS:000975506700001
|2 WOS
037 _ _ |a FZJ-2023-02283
082 _ _ |a 670
100 1 _ |a Brinkmann, Malte
|0 P:(DE-HGF)0
|b 0
|e Corresponding author
245 _ _ |a Impact of the contacting scheme on I-V measurements of metallization-free silicon heterojunction solar cells
260 _ _ |a Les Ulis
|c 2023
|b EDP Sciences
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1696852441_26498
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a I-V measurements are sensitive to the number and positioning of current and voltage sensingcontacts. For busbarless solar cells, measurement setups have been developed using current collection wires andseparate voltage sense contacts. Placing the latter at a defined position enables a grid resistance neglectingmeasurement and thus I-V characteristics independent from the contacting system. This technique has beendeveloped for solar cells having a finger grid and good conductivity in the direction of the fingers. The optimalposition of the sense contact in case offinger-free silicon heterojunction solar cells has not yet been studied. Here, thelateral charge carrier transport occurs ina transparentconductiveoxide layer resulting ina higher lateral resistance.We perform finite difference method simulations of HJT solar cells without front metallization to investigate theimpact of high lateral resistances on the I-Vmeasurement of solar cells.We showthe high sensitivity on thenumberof used wires for contacting as well as the position of the sense contact for the voltage measurement. Using thesimulations,we are able toexplainthe highdifferenceofupto 7.5%infill factormeasurements ofmetal free solar cellswith varying TCO sheet resistances between two measurement systems using different contacting setups. Wepropose a method to compensate for the contacting system to achieve a grid-resistance neglecting measurementwith both systems allowing a reduction of the FF difference to below 1.5%.
536 _ _ |a 1213 - Cell Design and Development (POF4-121)
|0 G:(DE-HGF)POF4-1213
|c POF4-121
|f POF IV
|x 0
588 _ _ |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de
700 1 _ |a Haase, Felix
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Bothe, Karsten
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Bittkau, Karsten
|0 P:(DE-Juel1)130219
|b 3
700 1 _ |a Lambertz, Andreas
|0 P:(DE-Juel1)130263
|b 4
700 1 _ |a Duan, Weiyuan
|0 P:(DE-Juel1)169946
|b 5
700 1 _ |a Ding, Kaining
|0 P:(DE-Juel1)130233
|b 6
700 1 _ |a Sperlich, Hans-Peter
|0 P:(DE-HGF)0
|b 7
700 1 _ |a Waltinger, Andreas
|0 P:(DE-HGF)0
|b 8
700 1 _ |a Schulte-Huxel, Henning
|0 P:(DE-HGF)0
|b 9
|e Corresponding author
773 _ _ |a 10.1051/epjpv/2023009
|g Vol. 14, p. 18 -
|0 PERI:(DE-600)2640487-4
|p 18
|t EPJ Photovoltaics
|v 14
|y 2023
|x 2105-0716
856 4 _ |u https://doi.org/10.1051/epjpv/2023009
856 4 _ |u https://juser.fz-juelich.de/record/1008321/files/20220511-EPJ-Impact%20of%20Contacting%20on%20measurement%20of%20metal%20free%20solar%20cells_V6.pdf
|y OpenAccess
|z StatID:(DE-HGF)0510
856 4 _ |u https://juser.fz-juelich.de/record/1008321/files/EPJPV14_18_Impact%20of%20the%20contacting%20scheme%20on%20I-V%20measurements%20of%20metallization-free%20silicon%20heterojunction%20solar%20cells.pdf
|y Restricted
|z StatID:(DE-HGF)0599
909 C O |o oai:juser.fz-juelich.de:1008321
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)130219
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)130263
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 5
|6 P:(DE-Juel1)169946
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)130233
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Materialien und Technologien für die Energiewende (MTET)
|1 G:(DE-HGF)POF4-120
|0 G:(DE-HGF)POF4-121
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Photovoltaik und Windenergie
|9 G:(DE-HGF)POF4-1213
|x 0
914 1 _ |y 2023
915 _ _ |a Creative Commons Attribution CC BY 4.0
|0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a Article Processing Charges
|0 StatID:(DE-HGF)0561
|2 StatID
|d 2022-11-08
915 _ _ |a Fees
|0 StatID:(DE-HGF)0700
|2 StatID
|d 2022-11-08
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b EPJ PHOTOVOLT : 2022
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0501
|2 StatID
|b DOAJ Seal
|d 2023-04-12T14:47:25Z
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0500
|2 StatID
|b DOAJ
|d 2023-04-12T14:47:25Z
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b DOAJ : Peer review
|d 2023-04-12T14:47:25Z
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0600
|2 StatID
|b Ebsco Academic Search
|d 2023-08-25
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b ASC
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2023-08-25
915 _ _ |a WoS
|0 StatID:(DE-HGF)0112
|2 StatID
|b Emerging Sources Citation Index
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2023-08-25
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2023-08-25
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)IEK-5-20101013
|k IEK-5
|l Photovoltaik
|x 0
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-5-20101013
981 _ _ |a I:(DE-Juel1)IMD-3-20101013


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21