001009470 001__ 1009470
001009470 005__ 20250701125920.0
001009470 0247_ $$2datacite_doi$$a10.34734/FZJ-2023-02807
001009470 037__ $$aFZJ-2023-02807
001009470 1001_ $$0P:(DE-Juel1)133673$$aHanslik, R.$$b0
001009470 1112_ $$aEighth European Conference on Neutron Scattering$$cTUM Department of Mechanical Engineering and the new Science Congress Center Munich$$d2023-03-19 - 2023-03-23$$gECNS 2023$$wGermany
001009470 245__ $$aShielding design for the High Brilliance neutron Source (HBS) target station
001009470 260__ $$c2023
001009470 3367_ $$033$$2EndNote$$aConference Paper
001009470 3367_ $$2DataCite$$aOther
001009470 3367_ $$2BibTeX$$aINPROCEEDINGS
001009470 3367_ $$2DRIVER$$aconferenceObject
001009470 3367_ $$2ORCID$$aLECTURE_SPEECH
001009470 3367_ $$0PUB:(DE-HGF)6$$2PUB:(DE-HGF)$$aConference Presentation$$bconf$$mconf$$s1690199558_12746$$xInvited
001009470 520__ $$aIn recent years, the development of high-current accelerator-based neutron sources (HiCANS) has gained in interest to propose a novel option for the next generation of neutron sources. In HiCANS high neutron yields are achieved by irradiating metal targets with proton beams with energies in the MeV range bellow the spallation threshold and currents of several tens of milliamps. Based on this concept, the High Brilliance neutron Source (HBS) project was developed at Forschungszentrum Jülich to deliver a high flux of neutrons to various scattering, analytics and imaging instruments.Relying on the experience and challenges of assembling the HBS shielding prototype at Forschungszentrum Jülich, the HBS target station shielding was developed from several layers of lead and borated polyethylene with a suitable stepped support structure. The aim of the shielding is to keep the dose rate in the monitored area well below the radiation protection criteria. The entire target station is modelled for particle transport simulation on the basis of the mechanical design. The dose rate distribution inside the target station as well as on the outside of the bunker walls is calculated during beam operation and also when the beam is switched off. The analysis of neutron and gamma flux and dose rate distribution in the target station from the radiation protection aspects will be presented.This work is part of the collaboration within ELENA and LENS on the development of HiCANS.
001009470 536__ $$0G:(DE-HGF)POF4-632$$a632 - Materials – Quantum, Complex and Functional Materials (POF4-632)$$cPOF4-632$$fPOF IV$$x0
001009470 536__ $$0G:(DE-HGF)POF4-6G4$$a6G4 - Jülich Centre for Neutron Research (JCNS) (FZJ) (POF4-6G4)$$cPOF4-6G4$$fPOF IV$$x1
001009470 7001_ $$0P:(DE-Juel1)133630$$aAchten, R.$$b1
001009470 7001_ $$0P:(DE-Juel1)131296$$aRandriamalala, T. H.$$b2
001009470 7001_ $$0P:(DE-Juel1)7897$$aLi, Jingjing$$b3
001009470 7001_ $$0P:(DE-Juel1)130382$$aMauerhofer, E.$$b4
001009470 7001_ $$0P:(DE-Juel1)169802$$aBaggemann, Johannes$$b5$$ufzj
001009470 7001_ $$0P:(DE-Juel1)131055$$aZakalek, P.$$b6
001009470 7001_ $$0P:(DE-Juel1)130928$$aRücker, U.$$b7
001009470 7001_ $$0P:(DE-Juel1)168124$$aGutberlet, T.$$b8
001009470 7001_ $$0P:(DE-Juel1)130572$$aBrückel, T.$$b9$$ufzj
001009470 8564_ $$uhttps://juser.fz-juelich.de/record/1009470/files/Abstract_ECNS2023_Hanslik.pdf$$yOpenAccess
001009470 909CO $$ooai:juser.fz-juelich.de:1009470$$pdriver$$pVDB$$popen_access$$popenaire
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133673$$aForschungszentrum Jülich$$b0$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133630$$aForschungszentrum Jülich$$b1$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131296$$aForschungszentrum Jülich$$b2$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)7897$$aForschungszentrum Jülich$$b3$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130382$$aForschungszentrum Jülich$$b4$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)169802$$aForschungszentrum Jülich$$b5$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)131055$$aForschungszentrum Jülich$$b6$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130928$$aForschungszentrum Jülich$$b7$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)168124$$aForschungszentrum Jülich$$b8$$kFZJ
001009470 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130572$$aForschungszentrum Jülich$$b9$$kFZJ
001009470 9131_ $$0G:(DE-HGF)POF4-632$$1G:(DE-HGF)POF4-630$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lVon Materie zu Materialien und Leben$$vMaterials – Quantum, Complex and Functional Materials$$x0
001009470 9131_ $$0G:(DE-HGF)POF4-6G4$$1G:(DE-HGF)POF4-6G0$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lGroßgeräte: Materie$$vJülich Centre for Neutron Research (JCNS) (FZJ)$$x1
001009470 9141_ $$y2023
001009470 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
001009470 9201_ $$0I:(DE-Juel1)JCNS-2-20110106$$kJCNS-2$$lStreumethoden$$x0
001009470 9201_ $$0I:(DE-Juel1)PGI-4-20110106$$kPGI-4$$lStreumethoden$$x1
001009470 9201_ $$0I:(DE-Juel1)JCNS-HBS-20180709$$kJCNS-HBS$$lHigh Brilliance Source$$x2
001009470 9201_ $$0I:(DE-82)080009_20140620$$kJARA-FIT$$lJARA-FIT$$x3
001009470 9201_ $$0I:(DE-Juel1)ZEA-1-20090406$$kZEA-1$$lZentralinstitut für Technologie$$x4
001009470 9201_ $$0I:(DE-Juel1)JCNS-ESS-20170404$$kJCNS-ESS$$lJCNS-ESS$$x5
001009470 9801_ $$aFullTexts
001009470 980__ $$aconf
001009470 980__ $$aVDB
001009470 980__ $$aUNRESTRICTED
001009470 980__ $$aI:(DE-Juel1)JCNS-2-20110106
001009470 980__ $$aI:(DE-Juel1)PGI-4-20110106
001009470 980__ $$aI:(DE-Juel1)JCNS-HBS-20180709
001009470 980__ $$aI:(DE-82)080009_20140620
001009470 980__ $$aI:(DE-Juel1)ZEA-1-20090406
001009470 980__ $$aI:(DE-Juel1)JCNS-ESS-20170404
001009470 981__ $$aI:(DE-Juel1)ITE-20250108
001009470 981__ $$aI:(DE-Juel1)JCNS-2-20110106