001019313 001__ 1019313
001019313 005__ 20240116084327.0
001019313 0247_ $$2doi$$a10.3390/ijms242417272
001019313 0247_ $$2ISSN$$a1422-0067
001019313 0247_ $$2ISSN$$a1661-6596
001019313 0247_ $$2datacite_doi$$a10.34734/FZJ-2023-05287
001019313 0247_ $$2pmid$$a38139102
001019313 0247_ $$2WOS$$aWOS:001132844200001
001019313 037__ $$aFZJ-2023-05287
001019313 041__ $$aEnglish
001019313 082__ $$a540
001019313 1001_ $$0P:(DE-Juel1)177991$$aAbuawad, Abdalhalim$$b0$$ufzj
001019313 245__ $$aDNA Sensor for the Detection of Brucella spp. Based on Magnetic Nanoparticle Markers
001019313 260__ $$aBasel$$bMolecular Diversity Preservation International$$c2023
001019313 3367_ $$2DRIVER$$aarticle
001019313 3367_ $$2DataCite$$aOutput Types/Journal article
001019313 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1702471945_27254
001019313 3367_ $$2BibTeX$$aARTICLE
001019313 3367_ $$2ORCID$$aJOURNAL_ARTICLE
001019313 3367_ $$00$$2EndNote$$aJournal Article
001019313 520__ $$aDue to the limitations of conventional Brucella detection methods, including safety concerns, long incubation times, and limited specificity, the development of a rapid, selective, and accu-rate technique for the early detection of Brucella in livestock animals is crucial to prevent the spread of the associated disease. In the present study, we introduce a magnetic nanoparticle marker-based biosensor using frequency mixing magnetic detection for point-of-care testing and quantification of Brucella DNA. Superparamagnetic nanoparticles were used as magnetically measured markers to selectively detect the target DNA hybridized with its complementary cap-ture probes immobilized on a porous polyethylene filter. Experimental conditions like density and length of the probes, hybridization time and temperature, and magnetic binding specificity, sensitivity, and detection limit were investigated and optimized. Our sensor demonstrated a relatively fast detection time of approximately 10 min, with a detection limit of 55 copies (0.09 fM) when tested using DNA amplified from Brucella genetic material. In addition, the detection specificity was examined using gDNA from Brucella and other zoonotic bacteria that may coexist in the same niche, confirming the method’s selectivity for Brucella DNA. Our proposed biosensor has the potential to be used for the early detection of Brucella bacteria in the field and can con-tribute to disease control measures.
001019313 536__ $$0G:(DE-HGF)POF4-5241$$a5241 - Molecular Information Processing in Cellular Systems (POF4-524)$$cPOF4-524$$fPOF IV$$x0
001019313 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
001019313 7001_ $$00000-0002-7083-3986$$aAshhab, Yaqoub$$b1
001019313 7001_ $$0P:(DE-Juel1)128713$$aOffenhäusser, Andreas$$b2
001019313 7001_ $$0P:(DE-Juel1)128697$$aKrause, Hans-Joachim$$b3$$eCorresponding author$$ufzj
001019313 773__ $$0PERI:(DE-600)2019364-6$$a10.3390/ijms242417272$$gVol. 24, no. 24, p. 17272 -$$n24$$p17272 -$$tInternational journal of molecular sciences$$v24$$x1422-0067$$y2023
001019313 8564_ $$uhttps://juser.fz-juelich.de/record/1019313/files/Open%20Access%20Paper.pdf$$yOpenAccess
001019313 8564_ $$uhttps://juser.fz-juelich.de/record/1019313/files/Open%20Access%20Paper.gif?subformat=icon$$xicon$$yOpenAccess
001019313 8564_ $$uhttps://juser.fz-juelich.de/record/1019313/files/Open%20Access%20Paper.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
001019313 8564_ $$uhttps://juser.fz-juelich.de/record/1019313/files/Open%20Access%20Paper.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
001019313 8564_ $$uhttps://juser.fz-juelich.de/record/1019313/files/Open%20Access%20Paper.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
001019313 8767_ $$d2024-01-12$$eAPC$$jZahlung erfolgt
001019313 909CO $$ooai:juser.fz-juelich.de:1019313$$pdnbdelivery$$popenCost$$pVDB$$pdriver$$pOpenAPC$$popen_access$$popenaire
001019313 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)177991$$aForschungszentrum Jülich$$b0$$kFZJ
001019313 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128713$$aForschungszentrum Jülich$$b2$$kFZJ
001019313 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128697$$aForschungszentrum Jülich$$b3$$kFZJ
001019313 9131_ $$0G:(DE-HGF)POF4-524$$1G:(DE-HGF)POF4-520$$2G:(DE-HGF)POF4-500$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-5241$$aDE-HGF$$bKey Technologies$$lNatural, Artificial and Cognitive Information Processing$$vMolecular and Cellular Information Processing$$x0
001019313 9141_ $$y2023
001019313 915pc $$0PC:(DE-HGF)0000$$2APC$$aAPC keys set
001019313 915pc $$0PC:(DE-HGF)0001$$2APC$$aLocal Funding
001019313 915pc $$0PC:(DE-HGF)0002$$2APC$$aDFG OA Publikationskosten
001019313 915pc $$0PC:(DE-HGF)0003$$2APC$$aDOAJ Journal
001019313 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2023-08-25
001019313 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
001019313 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bINT J MOL SCI : 2022$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bINT J MOL SCI : 2022$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2023-07-07T16:31:47Z
001019313 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2023-07-07T16:31:47Z
001019313 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0700$$2StatID$$aFees$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
001019313 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0561$$2StatID$$aArticle Processing Charges$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0320$$2StatID$$aDBCoverage$$bPubMed Central$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2023-08-25
001019313 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bDOAJ : Anonymous peer review$$d2023-07-07T16:31:47Z
001019313 920__ $$lyes
001019313 9201_ $$0I:(DE-Juel1)IBI-3-20200312$$kIBI-3$$lBioelektronik$$x0
001019313 9801_ $$aFullTexts
001019313 980__ $$ajournal
001019313 980__ $$aVDB
001019313 980__ $$aUNRESTRICTED
001019313 980__ $$aI:(DE-Juel1)IBI-3-20200312
001019313 980__ $$aAPC