AU - Hinz, Carsten
AU - Pflugfelder, Daniel
AU - Metzner, Ralf
AU - Streun, Matthias
AU - Scheins, Jürgen
AU - Koller, Robert
TI - Corrections for Quantitative Image Reconstruction with <i>pheno</i>PET, a Plant Dedicated PET Scanner
M1 - FZJ-2024-00265
PY - 2023
AB - Positron Emission Tomography (PET) allows the in vivo measurement of transport and allocation of recently produced photo-assimilates in plants, which are labeled with $^{11}$C. We operate the plant dedicated system <i>pheno</i>PET which consists of lutetium-yttrium oxyorthosilicate crystals readout with digital Silicon photomultiplier (Digital Photon Counter (DPC) by Phillips). The horizontal Field-of-View (FOV) with a diameter of 180$\,$mm and a height of 200$\,$mm allows the measurements of plants in their natural orientation. Raw data are analyzed offline and reconstructed with Ordinary Poisson Maximum Likelihood Expectation-Maximization (OP-MLEM) provided by PET Reconstruction Software Toolkit (PRESTO). We will present the implemented corrections to reconstruct quantitative images and approaches to speed-up those image reconstructions.
T2 - PET Electronics & Technologies 2023
CY - 12 Sep 2023 - 13 Sep 2023, Duisburg (Germany)
Y2 - 12 Sep 2023 - 13 Sep 2023
M2 - Duisburg, Germany
LB - PUB:(DE-HGF)24
DO - DOI:10.34734/FZJ-2024-00265
UR - https://juser.fz-juelich.de/record/1020570