001     1022606
005     20240712113147.0
024 7 _ |a 10.34734/FZJ-2024-01572
|2 datacite_doi
037 _ _ |a FZJ-2024-01572
041 _ _ |a English
100 1 _ |a Dao, Tuan Anh
|0 P:(DE-Juel1)187529
|b 0
|e Corresponding author
|u fzj
111 2 _ |a 74th Annual Meeting of the International Society of Electrochemistry
|c Lyon
|d 2023-09-03 - 2023-09-08
|w France
245 _ _ |a Investigation of localized hydrogen starvation in PEMFC with dynamic electrochemical impedance spectroscopy
260 _ _ |c 2023
336 7 _ |a Conference Paper
|0 33
|2 EndNote
336 7 _ |a Other
|2 DataCite
336 7 _ |a INPROCEEDINGS
|2 BibTeX
336 7 _ |a conferenceObject
|2 DRIVER
336 7 _ |a LECTURE_SPEECH
|2 ORCID
336 7 _ |a Conference Presentation
|b conf
|m conf
|0 PUB:(DE-HGF)6
|s 1707832900_17720
|2 PUB:(DE-HGF)
|x After Call
520 _ _ |a Hydrogen fuel utilization is one of the significant factors for the commercialization of PEMFC in automotive applications. Too low fuel utilisation decreases the driving range and fuel economy. However, too high utilization might lead to localized hydrogen starvation, which significantly reduces the lifetime and performance of the fuel cell system [1]. Hence, advanced diagnostics are needed to detect hydrogen starvation early and during operation [2].In this paper, a commercial MEA is tested under low hydrogen stoichiometry to simulate the spatial anode starvation condition. A newly developed electrochemical impedance spectroscopy (EIS) setup, which could measure up to 1000 impedance values in 1 second, is run in parallel for online characterization. The single cell stack is equipped with a current distribution measurement plate to confirm the starvation condition by the presence of a current deficit area in the anode outlet (Fig. 1). In addition, a novel localized CO stripping method is employed to validate the degradation on the cathode catalyst layer by measuring the localized distribution of the electrochemical active surface area (dECSA).This study shows that EIS spectra are non-sensitive towards hydrogen stoichiometry in the range of sufficient hydrogen supply, 𝜆𝜆>1. However, when stoichiometry drops close to 𝜆𝜆≈1 and the localized anode starvation starts to occur, the EIS spectra broaden remarkably, even though the cell performance does not yet indicate starvation. Furthermore, the EIS curves exhibit an oscillation in the middle and high-frequency range in both phase and magnitude when the cell is in the localized anode starvation condition (Fig. 2). The oscillation becomes more apparent when the starvation area is bigger. Meanwhile, the low-frequency regime exhibits inductive behavior, becoming more dominant with a more substantial effect of localized starvation. The dynamic current density measurement observes the hydrogen concentration oscillation in the anode outlet area. The localized CO Stripping reveals a significant drop of the dECSA on the cathode side in the same location, indicating cathode carbon corrosion under localized anode starvation conditions (Fig. 3).This work is a first step towards an onboard diagnosis method, which could detect the presence of localized anode starvation conditions early and take control measures to prevent degradation.References:[1] H. Chen et al., Energy Convers. Manag.182, 282-298 (2019).[2] Z. Tang et al. J. Power Sources 468, 228361 (2020).
536 _ _ |a 1231 - Electrochemistry for Hydrogen (POF4-123)
|0 G:(DE-HGF)POF4-1231
|c POF4-123
|f POF IV
|x 0
700 1 _ |a Kadyk, Thomas
|0 P:(DE-Juel1)178966
|b 1
|u fzj
700 1 _ |a Finkenwirth, Olav
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Eikerling, Michael
|0 P:(DE-Juel1)178034
|b 3
|u fzj
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/1022606/files/Abstract.pdf
856 4 _ |y OpenAccess
|x icon
|u https://juser.fz-juelich.de/record/1022606/files/Abstract.gif?subformat=icon
856 4 _ |y OpenAccess
|x icon-1440
|u https://juser.fz-juelich.de/record/1022606/files/Abstract.jpg?subformat=icon-1440
856 4 _ |y OpenAccess
|x icon-180
|u https://juser.fz-juelich.de/record/1022606/files/Abstract.jpg?subformat=icon-180
856 4 _ |y OpenAccess
|x icon-640
|u https://juser.fz-juelich.de/record/1022606/files/Abstract.jpg?subformat=icon-640
909 C O |o oai:juser.fz-juelich.de:1022606
|p openaire
|p open_access
|p VDB
|p driver
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)187529
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)178966
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)178034
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Materialien und Technologien für die Energiewende (MTET)
|1 G:(DE-HGF)POF4-120
|0 G:(DE-HGF)POF4-123
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Chemische Energieträger
|9 G:(DE-HGF)POF4-1231
|x 0
914 1 _ |y 2023
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
920 1 _ |0 I:(DE-Juel1)IEK-13-20190226
|k IEK-13
|l IEK-13
|x 0
980 1 _ |a FullTexts
980 _ _ |a conf
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-13-20190226
981 _ _ |a I:(DE-Juel1)IET-3-20190226


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21