001     1024567
005     20250203103131.0
024 7 _ |a 10.1002/batt.202200414
|2 doi
024 7 _ |a 10.34734/FZJ-2024-02243
|2 datacite_doi
024 7 _ |a WOS:000910591400001
|2 WOS
037 _ _ |a FZJ-2024-02243
082 _ _ |a 540
100 1 _ |a Koltermann, Lucas
|0 0000-0002-8076-4590
|b 0
|e Corresponding author
245 _ _ |a Operational Validation of a Power Distribution Algorithm for a Modular Megawatt Battery Storage System
260 _ _ |a Weinheim
|c 2023
|b Wiley-VCH
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1712752472_24399
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
500 _ _ |a Zudem unterstützt durch das BMWK Projekt EMMUseBat (FundingCode:03EI4034)
520 _ _ |a Large-scale battery storage systems have become popular for various grid services in recent years. A worldwide market growth for battery storage has led to increased competition in several grid service markets. Modular large-scale battery storage systems require a safe, highly available, and intelligent energy management system (EMS) in order to be economically competitive. One component of this EMS is the control for distributing the power requests between individual battery units of the large-scale battery storage system. As the EMS is usually undisclosed intellectual property of the system manufacturers, there is only little information on real-world operation available. To contribute, we present a rule-based power distribution algorithm (SPDA) in this paper and validate it through field tests on a 6 MW/7.5 MWh system that is providing frequency containment reserve to the German power grid. The results show that especially when combining different battery technologies, the SPDA can exploit individual technological strengths. In this way, the state of charge of the batteries, energy throughput and power load of the batteries can be controlled to extend the lifetime. Moreover, the SPDA managed to shift nearly 80 % of the energy throughput to one battery unit to protect less cyclic stable batteries and make use of the advantage of cyclic stable battery technologies, while fulfilling all grid service requirements. By shifting those large quantities of the energy throughput to more cyclic stable battery units, the large-scale battery storage system experienced in sum up to 45 % less cyclic aging with the SPDA than with a symmetrical power distribution algorithm. Furthermore, the operational efficiency of a large-scale battery storage system can be significantly improved via additional software adaptations of the power distribution, depending on the system layout.
536 _ _ |a 1223 - Batteries in Application (POF4-122)
|0 G:(DE-HGF)POF4-1223
|c POF4-122
|f POF IV
|x 0
536 _ _ |a BMWK-03ESP265F - M5BAT: Modularer multi-Megawatt multi-Technologie Mittelspannungsbatteriespeicher; Teilvorhaben: Entwicklung von Li-Ionen Batterien, Monitoring und Erstellung eines Designhandbuchs (BMWK-03ESP265F)
|0 G:(DE-82)BMWK-03ESP265F
|c BMWK-03ESP265F
|x 1
588 _ _ |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de
700 1 _ |a Jacqué, Kevin
|0 0000-0003-1909-5620
|b 1
700 1 _ |a Figgener, Jan
|0 0000-0003-2216-9432
|b 2
700 1 _ |a Zurmühlen, Sebastian
|0 0000-0003-3073-0744
|b 3
700 1 _ |a Sauer, Dirk Uwe
|0 P:(DE-Juel1)172625
|b 4
773 _ _ |a 10.1002/batt.202200414
|g Vol. 6, no. 3, p. e202200414
|0 PERI:(DE-600)2897248-X
|n 3
|p e202200414
|t Batteries & supercaps
|v 6
|y 2023
|x 2566-6223
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/1024567/files/2022_12_16_Leistungsaufteilung.pdf
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/1024567/files/Batteries%20Supercaps%20-%202022%20-%20Koltermann%20-%20Operational%20Validation%20of%20a%20Power%20Distribution%20Algorithm%20for%20a%20Modular%20Megawatt.pdf
856 4 _ |y OpenAccess
|x icon
|u https://juser.fz-juelich.de/record/1024567/files/2022_12_16_Leistungsaufteilung.gif?subformat=icon
856 4 _ |y OpenAccess
|x icon-1440
|u https://juser.fz-juelich.de/record/1024567/files/2022_12_16_Leistungsaufteilung.jpg?subformat=icon-1440
856 4 _ |y OpenAccess
|x icon-180
|u https://juser.fz-juelich.de/record/1024567/files/2022_12_16_Leistungsaufteilung.jpg?subformat=icon-180
856 4 _ |y OpenAccess
|x icon-640
|u https://juser.fz-juelich.de/record/1024567/files/2022_12_16_Leistungsaufteilung.jpg?subformat=icon-640
856 4 _ |y OpenAccess
|x icon
|u https://juser.fz-juelich.de/record/1024567/files/Batteries%20Supercaps%20-%202022%20-%20Koltermann%20-%20Operational%20Validation%20of%20a%20Power%20Distribution%20Algorithm%20for%20a%20Modular%20Megawatt.gif?subformat=icon
856 4 _ |y OpenAccess
|x icon-1440
|u https://juser.fz-juelich.de/record/1024567/files/Batteries%20Supercaps%20-%202022%20-%20Koltermann%20-%20Operational%20Validation%20of%20a%20Power%20Distribution%20Algorithm%20for%20a%20Modular%20Megawatt.jpg?subformat=icon-1440
856 4 _ |y OpenAccess
|x icon-180
|u https://juser.fz-juelich.de/record/1024567/files/Batteries%20Supercaps%20-%202022%20-%20Koltermann%20-%20Operational%20Validation%20of%20a%20Power%20Distribution%20Algorithm%20for%20a%20Modular%20Megawatt.jpg?subformat=icon-180
856 4 _ |y OpenAccess
|x icon-640
|u https://juser.fz-juelich.de/record/1024567/files/Batteries%20Supercaps%20-%202022%20-%20Koltermann%20-%20Operational%20Validation%20of%20a%20Power%20Distribution%20Algorithm%20for%20a%20Modular%20Megawatt.jpg?subformat=icon-640
909 C O |o oai:juser.fz-juelich.de:1024567
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)172625
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Materialien und Technologien für die Energiewende (MTET)
|1 G:(DE-HGF)POF4-120
|0 G:(DE-HGF)POF4-122
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Elektrochemische Energiespeicherung
|9 G:(DE-HGF)POF4-1223
|x 0
914 1 _ |y 2024
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2023-08-25
915 _ _ |a Creative Commons Attribution CC BY 4.0
|0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b BATTERIES SUPERCAPS : 2022
|d 2023-08-25
915 _ _ |a IF >= 5
|0 StatID:(DE-HGF)9905
|2 StatID
|b BATTERIES SUPERCAPS : 2022
|d 2023-08-25
915 _ _ |a DEAL Wiley
|0 StatID:(DE-HGF)3001
|2 StatID
|d 2023-08-25
|w ger
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2023-08-25
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2023-08-25
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2023-08-25
920 1 _ |0 I:(DE-Juel1)IEK-12-20141217
|k IEK-12
|l Helmholtz-Institut Münster Ionenleiter für Energiespeicher
|x 0
980 1 _ |a FullTexts
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)IEK-12-20141217
981 _ _ |a I:(DE-Juel1)IMD-4-20141217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21