@INPROCEEDINGS{Manzhura:1024579,
author = {Manzhura, O. and Caselle, M. and Ardila-Perez, L. E. and
Calvo, D. and Chilingaryan, S. and Cossio, F. and
Dritschler, T. and Kopmann, A. and Lenta, F. and Mazza, G.
and Peter, M. and Sidorenko, V. and Staněk, P. and
Stockmanns, T. and Tomášek, L. and Tröll, N. and Unger,
K. L. and Zaunick, H.-G. and Becker, J. and Brinkmann,
K.-T.},
title = {{T}he data acquisition system for the {PANDA}
{M}icro-{V}ertex {D}etector},
journal = {Journal of Instrumentation},
volume = {19},
number = {03},
issn = {1748-0221},
address = {London},
publisher = {Inst. of Physics},
reportid = {FZJ-2024-02253},
pages = {C03036 -},
year = {2024},
abstract = {The PANDA (antiProton ANnihilation at DArmstadt) experiment
will study the strong interaction in annihilation reactions
between an antiproton beam and a stationary cluster jet
target. The PANDA detector will be composed of several
sub-detectors designed for tracking, particle identification
and calorimetry. The Micro-Vertex Detector (MVD) is the
innermost part of the tracking system surrounding the
interaction region, which is designed for precise vertex and
tracking detection. It consists of silicon pixel and
double-sided microstrip detectors. For the readout of the
microstrip sensors an ASIC called ToASt (Torino Asic for
Strip readout) is being developed in 0.11 μm CMOS
technology at INFN Turin. The ASIC takes advantage of both
Time-over-Threshold and Time-of-Arrival methods to
accurately measure the event's energy and timestamp. To
sustain the acquisition of the microstrip sensors a MDC
(Module Data Concentrator) ASIC is under development at KIT.
Up to eight ToASt front-ends' data streams are multiplexed,
read out and processed by one MDC. The data of several MDCs
are collected and processed by the off-detector readout card
MMB (MVD Multiplexer Board), also under development at KIT.
The processed data is then transferred via 100 GbE optical
links to the computing nodes. The ToASt chips have been
integrated with the FPGA implementation of the MDC to form
the first fully functional detector module. Beam tests have
been performed at the COSY facility in Jülich. This paper
focuses on the design of MDC ASIC and MMB board, the
integration with the ToASt and presents preliminary beam
test results.},
month = {Oct},
date = {2023-10-01},
organization = {Topical Workshop on Electronics for
Particle Physics, Sardinia (Italy), 1
Oct 2023 - 6 Oct 2023},
cin = {IKP-1},
ddc = {610},
cid = {I:(DE-Juel1)IKP-1-20111104},
pnm = {6G12 - FAIR (GSI) (POF4-6G12)},
pid = {G:(DE-HGF)POF4-6G12},
typ = {PUB:(DE-HGF)16 / PUB:(DE-HGF)8},
UT = {WOS:001189616700003},
doi = {10.1088/1748-0221/19/03/C03036},
url = {https://juser.fz-juelich.de/record/1024579},
}