@ARTICLE{Ioffe:1024774,
author = {Ioffe, Alexander and Konik, Petr},
title = {{A} new method to find out the optimal neutron moderator
size based on neutron scattering instrument parameters},
journal = {Nuclear instruments $\&$ methods in physics research /
Section A},
volume = {1056},
issn = {0167-5087},
address = {Amsterdam},
publisher = {North-Holland Publ. Co.},
reportid = {FZJ-2024-02440},
pages = {168643},
year = {2023},
abstract = {Simple and fast analytic method to find optimal
combinations of sizes of neutron moderator and optical
system entrance, allowing for the full sample illumination
with minimum to none background, is developed. In the case
of employing low-dimensional para-hydrogen moderators with
enhanced neutron beam brilliance, the method allows to
determine the minimum size of moderator, which provides the
highest sample flux while keeping the sample fully
illuminated.This method can be used during the design of new
neutron sources, upgrades of neutron optical systems and
moderator replacements.},
cin = {JCNS-FRM-II / MLZ / JCNS-4},
ddc = {530},
cid = {I:(DE-Juel1)JCNS-FRM-II-20110218 / I:(DE-588b)4597118-3 /
I:(DE-Juel1)JCNS-4-20201012},
pnm = {6G4 - Jülich Centre for Neutron Research (JCNS) (FZJ)
(POF4-6G4) / 632 - Materials – Quantum, Complex and
Functional Materials (POF4-632)},
pid = {G:(DE-HGF)POF4-6G4 / G:(DE-HGF)POF4-632},
experiment = {EXP:(DE-MLZ)NOSPEC-20140101},
typ = {PUB:(DE-HGF)16},
UT = {WOS:001073031500001},
doi = {10.1016/j.nima.2023.168643},
url = {https://juser.fz-juelich.de/record/1024774},
}