001     1024911
005     20250203103205.0
024 7 _ |a 10.1039/D3TA00097D
|2 doi
024 7 _ |a 2050-7488
|2 ISSN
024 7 _ |a 2050-7496
|2 ISSN
024 7 _ |a WOS:000955095100001
|2 WOS
037 _ _ |a FZJ-2024-02561
082 _ _ |a 530
100 1 _ |a Adhitama, Egy
|0 0000-0002-7637-1356
|b 0
|e Corresponding author
245 _ _ |a On the direct correlation between the copper current collector surface area and ‘dead Li’ formation in zero-excess Li metal batteries
260 _ _ |a London ˜[u.a.]œ
|c 2023
|b RSC
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1712740549_24403
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a In ‘zero-excess’ (often called ‘anode-free’) lithium metal batteries (ZE-LMBs), three-dimensional (3D) current collectors (CC) with a high surface area have been reported to effectively reduce the local current density and minimize the electronically and/or ionically isolated Li metal, so-called ‘dead Li’. In most of the published works on 3D CCs for ZE-LMBs, the discussion has oftentimes primarily emphasized the relationship between the functionality of the 3D surface structure and its effect on enhanced electrochemical performance. Therefore, it is important to take a deeper look at this relationship by controlling the surface features and surface chemistry of CCs. In this work, the direct correlation between the surface area of CCs and ‘dead Li’ is thoroughly evaluated. The Li deposition behavior at the entire CC is also elucidated. A fair comparison is maintained by precisely controlling surface features and surface chemistry of the 3D copper CC which is realized by femtosecond-laser-ablation. ‘Dead Li’ is accurately quantified by gas chromatography coupled with a barrier discharge ionization detector. This study shall shed light on a deeper understanding of the correlation between surface area and ‘dead Li’ to pave the way for the application of ZE-LMBs.
536 _ _ |a 1221 - Fundamentals and Materials (POF4-122)
|0 G:(DE-HGF)POF4-1221
|c POF4-122
|f POF IV
|x 0
536 _ _ |a BACCARA - Battery and superCapacitor ChARActerization and testing (608491)
|0 G:(EU-Grant)608491
|c 608491
|f FP7-ENERGY-2013-1
|x 1
588 _ _ |a Dataset connected to DataCite
700 1 _ |a Refino, Andam Deatama
|0 0000-0001-9829-0971
|b 1
700 1 _ |a Brake, Tobias
|0 0000-0002-8696-0429
|b 2
700 1 _ |a Pleie, Jan
|0 P:(DE-Juel1)184721
|b 3
700 1 _ |a Schmidt, Christina
|0 P:(DE-Juel1)185885
|b 4
|u fzj
700 1 _ |a Demelash, Feleke
|0 P:(DE-HGF)0
|b 5
700 1 _ |a Neuhaus, Kerstin
|0 P:(DE-Juel1)181017
|b 6
|u fzj
700 1 _ |a Bornemann, Steffen
|0 P:(DE-HGF)0
|b 7
700 1 _ |a Wiemers-Meyer, Simon
|0 P:(DE-HGF)0
|b 8
700 1 _ |a Peiner, Erwin
|0 P:(DE-HGF)0
|b 9
700 1 _ |a Winter, Martin
|0 P:(DE-Juel1)166130
|b 10
|u fzj
700 1 _ |a Wasisto, Hutomo Suryo
|0 0000-0002-4522-3625
|b 11
700 1 _ |a Placke, Tobias
|0 P:(DE-HGF)0
|b 12
773 _ _ |a 10.1039/D3TA00097D
|g Vol. 11, no. 14, p. 7724 - 7734
|0 PERI:(DE-600)2702232-8
|n 14
|p 7724 - 7734
|t Journal of materials chemistry / A
|v 11
|y 2023
|x 2050-7488
856 4 _ |u https://juser.fz-juelich.de/record/1024911/files/On%20the%20direct%20correlation%20between%20the%20copper%20current%20collector%20surface%20area%20and%20%E2%80%98dead%20Li%E2%80%99%20formation%20in%20zero-excess%20Li%20metal%20batteries.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1024911/files/On%20the%20direct%20correlation%20between%20the%20copper%20current%20collector%20surface%20area%20and%20%E2%80%98dead%20Li%E2%80%99%20formation%20in%20zero-excess%20Li%20metal%20batteries.gif?subformat=icon
|x icon
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1024911/files/On%20the%20direct%20correlation%20between%20the%20copper%20current%20collector%20surface%20area%20and%20%E2%80%98dead%20Li%E2%80%99%20formation%20in%20zero-excess%20Li%20metal%20batteries.jpg?subformat=icon-1440
|x icon-1440
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1024911/files/On%20the%20direct%20correlation%20between%20the%20copper%20current%20collector%20surface%20area%20and%20%E2%80%98dead%20Li%E2%80%99%20formation%20in%20zero-excess%20Li%20metal%20batteries.jpg?subformat=icon-180
|x icon-180
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1024911/files/On%20the%20direct%20correlation%20between%20the%20copper%20current%20collector%20surface%20area%20and%20%E2%80%98dead%20Li%E2%80%99%20formation%20in%20zero-excess%20Li%20metal%20batteries.jpg?subformat=icon-640
|x icon-640
|y Restricted
909 C O |o oai:juser.fz-juelich.de:1024911
|p openaire
|p VDB
|p ec_fundedresources
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)185885
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)181017
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 10
|6 P:(DE-Juel1)166130
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Materialien und Technologien für die Energiewende (MTET)
|1 G:(DE-HGF)POF4-120
|0 G:(DE-HGF)POF4-122
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Elektrochemische Energiespeicherung
|9 G:(DE-HGF)POF4-1221
|x 0
914 1 _ |y 2024
915 _ _ |a National-Konsortium
|0 StatID:(DE-HGF)0430
|2 StatID
|d 2023-08-23
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2023-08-23
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2023-08-23
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2023-08-23
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2023-08-23
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2023-08-23
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
|d 2023-08-23
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
|d 2023-08-23
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b J MATER CHEM A : 2022
|d 2023-08-23
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2023-08-23
915 _ _ |a IF >= 10
|0 StatID:(DE-HGF)9910
|2 StatID
|b J MATER CHEM A : 2022
|d 2023-08-23
920 1 _ |0 I:(DE-Juel1)IEK-12-20141217
|k IEK-12
|l Helmholtz-Institut Münster Ionenleiter für Energiespeicher
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)IEK-12-20141217
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)IMD-4-20141217


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21