Home > Publications database > In situ tomography of lithium-ion battery cells enabled by scanning acoustic imaging > print |
001 | 1024925 | ||
005 | 20250203103351.0 | ||
024 | 7 | _ | |a 10.1016/j.jpowsour.2023.233295 |2 doi |
024 | 7 | _ | |a 0378-7753 |2 ISSN |
024 | 7 | _ | |a 1873-2755 |2 ISSN |
024 | 7 | _ | |a 10.34734/FZJ-2024-02575 |2 datacite_doi |
024 | 7 | _ | |a WOS:001024330300001 |2 WOS |
037 | _ | _ | |a FZJ-2024-02575 |
082 | _ | _ | |a 620 |
100 | 1 | _ | |a Wasylowski, David |0 0000-0001-8629-7439 |b 0 |e Corresponding author |
245 | _ | _ | |a In situ tomography of lithium-ion battery cells enabled by scanning acoustic imaging |
260 | _ | _ | |a New York, NY [u.a.] |c 2023 |b Elsevier |
336 | 7 | _ | |a article |2 DRIVER |
336 | 7 | _ | |a Output Types/Journal article |2 DataCite |
336 | 7 | _ | |a Journal Article |b journal |m journal |0 PUB:(DE-HGF)16 |s 1712750774_24401 |2 PUB:(DE-HGF) |
336 | 7 | _ | |a ARTICLE |2 BibTeX |
336 | 7 | _ | |a JOURNAL_ARTICLE |2 ORCID |
336 | 7 | _ | |a Journal Article |0 0 |2 EndNote |
500 | _ | _ | |a Zudem unterstützt durch BMBF Grants: MADAM4Life (grant number 03XP0327C), NUBase (grant number 03XP0322C) |
520 | _ | _ | |a Imaging the interior of battery cells provides vital information for battery manufacturing, as well as lifetime and performance prediction. This work demonstrates a scalable and in-situ method to image the structural state of battery cells with layer resolution. Building on our prior publication, we apply ultrasound waves on pouch cells and process the reflected instead of the transmitted wave. This allows us to utilize time-of-flight data to provide depth information for later signal parts. We develop and demonstrate an algorithm that dissects the reflected ultrasound wave and calculates individual reflections from material interfaces within the electrode stack by fitting their estimated envelopes onto the Hilbert transformation of the entire wave. Consecutive individual reflections are used to calculate the reflection coefficient from the material interface, which is then mapped onto a color map. Using this algorithm, we image an aged and pristine pouch cell from the same manufacturing batch. The generated images showed a clear correlation with optical images from a post-mortem analysis. Indications from the ultrasound image were verified as lithium-plating. |
536 | _ | _ | |a 1223 - Batteries in Application (POF4-122) |0 G:(DE-HGF)POF4-1223 |c POF4-122 |f POF IV |x 0 |
536 | _ | _ | |a InOPlaBat - In-Situ und Operando Plating Detektion in Batterien (13XP0352B) |0 G:(BMBF)13XP0352B |c 13XP0352B |x 1 |
588 | _ | _ | |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de |
700 | 1 | _ | |a Neubauer, Sven |b 1 |
700 | 1 | _ | |a Faber, Matthias |0 0000-0003-2617-743X |b 2 |
700 | 1 | _ | |a Ditler, Heinrich |0 0000-0002-4320-6207 |b 3 |
700 | 1 | _ | |a Sonnet, Morian |0 0000-0002-6168-2880 |b 4 |
700 | 1 | _ | |a Blömeke, Alexander |0 0000-0003-0943-9485 |b 5 |
700 | 1 | _ | |a Dechent, Philipp |0 P:(DE-HGF)0 |b 6 |
700 | 1 | _ | |a Gitis, Alexander |0 P:(DE-HGF)0 |b 7 |
700 | 1 | _ | |a Sauer, Dirk Uwe |0 P:(DE-Juel1)172625 |b 8 |
773 | _ | _ | |a 10.1016/j.jpowsour.2023.233295 |g Vol. 580, p. 233295 - |0 PERI:(DE-600)1491915-1 |p 233295 - |t Journal of power sources |v 580 |y 2023 |x 0378-7753 |
856 | 4 | _ | |y OpenAccess |u https://juser.fz-juelich.de/record/1024925/files/In%20situ%20tomography%20of%20lithium-ion%20battery%20cells%20enabled%20by%20scanning%20acoustic%20imaging.pdf |
856 | 4 | _ | |y OpenAccess |x icon |u https://juser.fz-juelich.de/record/1024925/files/In%20situ%20tomography%20of%20lithium-ion%20battery%20cells%20enabled%20by%20scanning%20acoustic%20imaging.gif?subformat=icon |
856 | 4 | _ | |y OpenAccess |x icon-1440 |u https://juser.fz-juelich.de/record/1024925/files/In%20situ%20tomography%20of%20lithium-ion%20battery%20cells%20enabled%20by%20scanning%20acoustic%20imaging.jpg?subformat=icon-1440 |
856 | 4 | _ | |y OpenAccess |x icon-180 |u https://juser.fz-juelich.de/record/1024925/files/In%20situ%20tomography%20of%20lithium-ion%20battery%20cells%20enabled%20by%20scanning%20acoustic%20imaging.jpg?subformat=icon-180 |
856 | 4 | _ | |y OpenAccess |x icon-640 |u https://juser.fz-juelich.de/record/1024925/files/In%20situ%20tomography%20of%20lithium-ion%20battery%20cells%20enabled%20by%20scanning%20acoustic%20imaging.jpg?subformat=icon-640 |
909 | C | O | |o oai:juser.fz-juelich.de:1024925 |p openaire |p open_access |p VDB |p driver |p dnbdelivery |
910 | 1 | _ | |a Forschungszentrum Jülich |0 I:(DE-588b)5008462-8 |k FZJ |b 8 |6 P:(DE-Juel1)172625 |
913 | 1 | _ | |a DE-HGF |b Forschungsbereich Energie |l Materialien und Technologien für die Energiewende (MTET) |1 G:(DE-HGF)POF4-120 |0 G:(DE-HGF)POF4-122 |3 G:(DE-HGF)POF4 |2 G:(DE-HGF)POF4-100 |4 G:(DE-HGF)POF |v Elektrochemische Energiespeicherung |9 G:(DE-HGF)POF4-1223 |x 0 |
914 | 1 | _ | |y 2024 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0150 |2 StatID |b Web of Science Core Collection |d 2023-08-28 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0300 |2 StatID |b Medline |d 2023-08-28 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1160 |2 StatID |b Current Contents - Engineering, Computing and Technology |d 2023-08-28 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0600 |2 StatID |b Ebsco Academic Search |d 2023-08-28 |
915 | _ | _ | |a Creative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0 |0 LIC:(DE-HGF)CCBYNCND4 |2 HGFVOC |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1150 |2 StatID |b Current Contents - Physical, Chemical and Earth Sciences |d 2023-08-28 |
915 | _ | _ | |a IF >= 5 |0 StatID:(DE-HGF)9905 |2 StatID |b J POWER SOURCES : 2022 |d 2023-08-28 |
915 | _ | _ | |a WoS |0 StatID:(DE-HGF)0113 |2 StatID |b Science Citation Index Expanded |d 2023-08-28 |
915 | _ | _ | |a OpenAccess |0 StatID:(DE-HGF)0510 |2 StatID |
915 | _ | _ | |a Peer Review |0 StatID:(DE-HGF)0030 |2 StatID |b ASC |d 2023-08-28 |
915 | _ | _ | |a JCR |0 StatID:(DE-HGF)0100 |2 StatID |b J POWER SOURCES : 2022 |d 2023-08-28 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0160 |2 StatID |b Essential Science Indicators |d 2023-08-28 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0200 |2 StatID |b SCOPUS |d 2023-08-28 |
915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0199 |2 StatID |b Clarivate Analytics Master Journal List |d 2023-08-28 |
920 | 1 | _ | |0 I:(DE-Juel1)IEK-12-20141217 |k IEK-12 |l Helmholtz-Institut Münster Ionenleiter für Energiespeicher |x 0 |
980 | 1 | _ | |a FullTexts |
980 | _ | _ | |a journal |
980 | _ | _ | |a VDB |
980 | _ | _ | |a UNRESTRICTED |
980 | _ | _ | |a I:(DE-Juel1)IEK-12-20141217 |
981 | _ | _ | |a I:(DE-Juel1)IMD-4-20141217 |
Library | Collection | CLSMajor | CLSMinor | Language | Author |
---|