001     1030413
005     20240905204428.0
037 _ _ |a FZJ-2024-05286
041 _ _ |a English
100 1 _ |a Meven, Martin
|0 P:(DE-Juel1)164297
|b 0
|e Corresponding author
|u fzj
111 2 _ |a MLZ Workshop : Automation in Diffraction
|c Garching
|d 2024-03-14 - 2024-03-15
|w Germany
245 _ _ |a Adaptive Data Aquisition at the Hot Single Crystal Diffractometer HEiDi at MLZ
260 _ _ |c 2024
336 7 _ |a Conference Paper
|0 33
|2 EndNote
336 7 _ |a Other
|2 DataCite
336 7 _ |a INPROCEEDINGS
|2 BibTeX
336 7 _ |a conferenceObject
|2 DRIVER
336 7 _ |a LECTURE_SPEECH
|2 ORCID
336 7 _ |a Conference Presentation
|b conf
|m conf
|0 PUB:(DE-HGF)6
|s 1725529003_11330
|2 PUB:(DE-HGF)
|x After Call
500 _ _ |a additional grant name: BMBF 05K19PA2: Entwicklung und Optimierung von Hochdruckprobenumgebung für polarisierte und unpolarisierte Neutronendiffraktion und - spektroskopie an den Instrumenten HEiDi, POLI, MIRA und DNS am Heinz Maier-Leibnitz Zentrum.
520 _ _ |a Single crystal neutron diffraction, especially with hot neutrons, supports various grand challenges in research as well as method developments. In regard to this the instrument HEiDi at the hot source of FRM II offers features like fast and high quality Bragg data collections up to very large Q (> 20/Å for λ=0.56Å) within a broad temperature range (2K < T < 1300K) and offers since 2019 also high pressure experiments (p < 10 GPa).The full exploitation of these options and the safe support of 24h/7d user operation requires a highly flexible and autonomous software for device control and data acquisition. Accordingly, the HEiDi software provides various routines in order to determine and to adopt in operando for the best possible parameters for sample centering, sample orientation and reflection collection or to avoid collisions and shading during running experiments. Other routines simulate the experiment in terms of expected beam time or completeness for optimized planning of the experiment. Recent activities focus on (i) porting the existing software and its features to a NICOS-based control system including the implementation of extended typical single-crystal multi-parameter measurements and (ii) integration of tools for the extraction of intensities from a new Li scintillator based area detector, an important step also for potential future applications such as PDF studies on disordered systems up to high Q.[1] M. Meven et al. (MLZ); Journal of large-scale research facilities 1 A7, (2015). [2] A. Grzechnik et al.; J. Appl. Cryst. 53(1), 1 - 6; (2020).
536 _ _ |a 6G4 - Jülich Centre for Neutron Research (JCNS) (FZJ) (POF4-6G4)
|0 G:(DE-HGF)POF4-6G4
|c POF4-6G4
|f POF IV
|x 0
536 _ _ |a 632 - Materials – Quantum, Complex and Functional Materials (POF4-632)
|0 G:(DE-HGF)POF4-632
|c POF4-632
|f POF IV
|x 1
650 2 7 |a Instrument and Method Development
|0 V:(DE-MLZ)SciArea-220
|2 V:(DE-HGF)
|x 0
650 2 7 |a Crystallography
|0 V:(DE-MLZ)SciArea-240
|2 V:(DE-HGF)
|x 1
650 1 7 |a Instrument and Method Development
|0 V:(DE-MLZ)GC-2002-2016
|2 V:(DE-HGF)
|x 0
693 _ _ |a Forschungs-Neutronenquelle Heinz Maier-Leibnitz
|e HEiDi: Single crystal diffractometer on hot source
|f SR9b
|1 EXP:(DE-MLZ)FRMII-20140101
|0 EXP:(DE-MLZ)HEIDI-20140101
|5 EXP:(DE-MLZ)HEIDI-20140101
|6 EXP:(DE-MLZ)SR9b-20140101
|x 0
700 1 _ |a Grzechnik, Andrzej
|0 P:(DE-Juel1)194570
|b 1
|u fzj
700 1 _ |a Brandl, Georg
|0 P:(DE-Juel1)166109
|b 2
|u fzj
700 1 _ |a Kleines, Harald
|0 P:(DE-Juel1)133905
|b 3
|u fzj
856 4 _ |u https://indico.frm2.tum.de/event/439/
856 4 _ |u https://juser.fz-juelich.de/record/1030413/files/abstract-9.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1030413/files/abstract-9.gif?subformat=icon
|x icon
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1030413/files/abstract-9.jpg?subformat=icon-1440
|x icon-1440
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1030413/files/abstract-9.jpg?subformat=icon-180
|x icon-180
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/1030413/files/abstract-9.jpg?subformat=icon-640
|x icon-640
|y Restricted
909 C O |o oai:juser.fz-juelich.de:1030413
|p VDB:MLZ
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)164297
910 1 _ |a RWTH Aachen
|0 I:(DE-588b)36225-6
|k RWTH
|b 0
|6 P:(DE-Juel1)164297
910 1 _ |a Heinz Maier-Leibnitz Zentrum
|0 I:(DE-588b)4597118-3
|k MLZ
|b 0
|6 P:(DE-Juel1)164297
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)194570
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)166109
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)133905
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Großgeräte: Materie
|1 G:(DE-HGF)POF4-6G0
|0 G:(DE-HGF)POF4-6G4
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-600
|4 G:(DE-HGF)POF
|v Jülich Centre for Neutron Research (JCNS) (FZJ)
|x 0
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Von Materie zu Materialien und Leben
|1 G:(DE-HGF)POF4-630
|0 G:(DE-HGF)POF4-632
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-600
|4 G:(DE-HGF)POF
|v Materials – Quantum, Complex and Functional Materials
|x 1
914 1 _ |y 2024
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)JCNS-FRM-II-20110218
|k JCNS-FRM-II
|l JCNS-FRM-II
|x 0
920 1 _ |0 I:(DE-Juel1)JCNS-2-20110106
|k JCNS-2
|l Streumethoden
|x 1
920 1 _ |0 I:(DE-Juel1)JCNS-4-20201012
|k JCNS-4
|l JCNS-4
|x 2
920 1 _ |0 I:(DE-588b)4597118-3
|k MLZ
|l Heinz Maier-Leibnitz Zentrum
|x 3
920 1 _ |0 I:(DE-82)080009_20140620
|k JARA-FIT
|l JARA-FIT
|x 4
980 _ _ |a conf
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)JCNS-FRM-II-20110218
980 _ _ |a I:(DE-Juel1)JCNS-2-20110106
980 _ _ |a I:(DE-Juel1)JCNS-4-20201012
980 _ _ |a I:(DE-588b)4597118-3
980 _ _ |a I:(DE-82)080009_20140620
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21