001     1031494
005     20240930212511.0
037 _ _ |a FZJ-2024-05700
100 1 _ |a Schmidt, Norberto
|0 P:(DE-Juel1)192138
|b 0
111 2 _ |a Deutsche Neutronstreutagung
|g DN 2024
|c RWTH Aachen
|d 2024-09-16 - 2024-09-18
|w Germany
245 _ _ |a Comparison of experimental and simulated neutron cold spectra for para- and ortho-hydrogen
260 _ _ |c 2024
336 7 _ |a Conference Paper
|0 33
|2 EndNote
336 7 _ |a INPROCEEDINGS
|2 BibTeX
336 7 _ |a conferenceObject
|2 DRIVER
336 7 _ |a CONFERENCE_POSTER
|2 ORCID
336 7 _ |a Output Types/Conference Poster
|2 DataCite
336 7 _ |a Poster
|b poster
|m poster
|0 PUB:(DE-HGF)24
|s 1727695327_30878
|2 PUB:(DE-HGF)
|x Invited
520 _ _ |a The High Brilliance Neutron Source (HBS) [1] project aims to develop a High-Current Accelerator-driven Neutron Source (HiCANS) for neutron scattering, analytics, and imaging. It will feature several cold neutron sources, including a liquid para-hydrogen moderator. At the Forschungszentrum Jülich, time-of-flight measurements were performed with the prototype of such a cryogenic moderator for different ratios between para- and ortho-hydrogen. In order to optimize the design of future instruments that will use this cold neutron source, an accurate description of the source characteristics is necessary, which requires simulations of the neutron transport to the detector for a comparison of simulated and experimental data.This work focuses on the comparison of various simulated spectra against experimental ones for different para- and ortho-hydrogen ratios. Several Monte Carlo codes, including MCNP, PHITS, McStas, VITESS, and KDSource, and nuclear data from the ENDF/B-VII.1, JENDL-4.0 and JENDL-5.0 libraries were utilized. The simulations started with the comparison of the proton-neutron yield spectra, continued with coupling the event files before and after the modeling of the neutron guide, and ended with the neutron time distribution at the detector. A good agreement between simulations and experiments was obtained, with a relative error below 20%.The results provide insights into the strengths and limitations of each Monte Carlo code and nuclear data library combination. Not only the observed discrepancies are discussed, but also the potential sources of uncertainty are identified. Also, the conclusions will help to improve the accuracy and reliability of neutron cold moderator designs, especially for projects that will deploy a para-hydrogen cold source such as the HBS.[1] T. Brückel et al, 2022. Technical Design Report High Brilliance Neutron Source. Forschungszentrum Jülich. https://doi.org/10.34734/FZJ-2023-03722
536 _ _ |a 632 - Materials – Quantum, Complex and Functional Materials (POF4-632)
|0 G:(DE-HGF)POF4-632
|c POF4-632
|f POF IV
|x 0
536 _ _ |a 6G4 - Jülich Centre for Neutron Research (JCNS) (FZJ) (POF4-6G4)
|0 G:(DE-HGF)POF4-6G4
|c POF4-6G4
|f POF IV
|x 1
700 1 _ |a Schwab, Alexander
|0 P:(DE-Juel1)180458
|b 1
|u fzj
700 1 _ |a Li, Jingjing
|b 2
700 1 _ |a Rücker, Ulrich
|0 P:(DE-Juel1)130928
|b 3
|u fzj
700 1 _ |a Voigt, Jörg
|0 P:(DE-Juel1)131018
|b 4
|u fzj
700 1 _ |a Lieutenant, Klaus
|0 P:(DE-Juel1)178839
|b 5
|u fzj
700 1 _ |a Damián, José Ignacio Márquez
|0 P:(DE-HGF)0
|b 6
700 1 _ |a Granada, Rolando
|0 P:(DE-HGF)0
|b 7
700 1 _ |a Dawidowski, Javier
|0 P:(DE-HGF)0
|b 8
700 1 _ |a Mauerhofer, Eric
|0 P:(DE-Juel1)130382
|b 9
|u fzj
700 1 _ |a Gutberlet, Thomas
|0 P:(DE-Juel1)168124
|b 10
|u fzj
700 1 _ |a Zakalek, Paul
|0 P:(DE-Juel1)131055
|b 11
|u fzj
909 C O |o oai:juser.fz-juelich.de:1031494
|p VDB
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)192138
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)180458
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)130928
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)131018
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 5
|6 P:(DE-Juel1)178839
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 9
|6 P:(DE-Juel1)130382
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 10
|6 P:(DE-Juel1)168124
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 11
|6 P:(DE-Juel1)131055
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Von Materie zu Materialien und Leben
|1 G:(DE-HGF)POF4-630
|0 G:(DE-HGF)POF4-632
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-600
|4 G:(DE-HGF)POF
|v Materials – Quantum, Complex and Functional Materials
|x 0
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Großgeräte: Materie
|1 G:(DE-HGF)POF4-6G0
|0 G:(DE-HGF)POF4-6G4
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-600
|4 G:(DE-HGF)POF
|v Jülich Centre for Neutron Research (JCNS) (FZJ)
|x 1
914 1 _ |y 2024
920 1 _ |0 I:(DE-Juel1)JCNS-2-20110106
|k JCNS-2
|l Streumethoden
|x 0
920 1 _ |0 I:(DE-Juel1)JCNS-HBS-20180709
|k JCNS-HBS
|l High Brilliance Source
|x 1
920 1 _ |0 I:(DE-82)080009_20140620
|k JARA-FIT
|l JARA-FIT
|x 2
980 _ _ |a poster
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)JCNS-2-20110106
980 _ _ |a I:(DE-Juel1)JCNS-HBS-20180709
980 _ _ |a I:(DE-82)080009_20140620
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21