      author       = {Streun, M. and Eguzo, C. and Gorke, H. and Heil, R. and
                      Hinz, C. and Keßel, D. and Koller, R. and Metzner, R. and
                      Pflugfelder, D. and Scheins, J. and Scherer, B. and
                      Wüstner, P. and van Waasen, S.},
      title        = {{T}he data acquisition system of pheno{PET}},
      journal      = {Journal of Instrumentation},
      volume       = {19},
      number       = {11},
      issn         = {1748-0221},
      address      = {London},
      publisher    = {Inst. of Physics},
      reportid     = {FZJ-2024-06763},
      pages        = {C11015 -},
      year         = {2024},
      abstract     = {The PET scanner phenoPET is a system dedicated for plant
                      research developed and used for phenotyping studies at the
                      Research Center in Jülich. The detectors consist of LYSO
                      scintillators and Philips digital silicon photomultipliers.
                      A central processing board collects their data and transfers
                      them through a USB-3 connection to the data acquisition
                      server. The USB-3 restricts the maximum output rate to 380
                      MB/s, which requires controlled data dropping on the board
                      in order to allow measurements with activities that would
                      exceed this limit. Presently we are developing a new readout
                      system that will eliminate this bottleneck. We will replace
                      the USB-3 by a fiber optics link with a maximum data rate of
                      2 GB/s. In addition, the new central board will provide an
                      embedded operation system (PetaLinux) that has direct access
                      to the hardware interfaces for configuration and monitoring
                      of the detector modules. This will allow the control
                      software to run directly on the board.},
      cin          = {ZEA-2 / IBG-2 / INM-4 / JSC},
      ddc          = {610},
      cid          = {I:(DE-Juel1)ZEA-2-20090406 / I:(DE-Juel1)IBG-2-20101118 /
                      I:(DE-Juel1)INM-4-20090406 / I:(DE-Juel1)JSC-20090406},
      pnm          = {2171 - Biological and environmental resources for
                      sustainable use (POF4-217)},
      pid          = {G:(DE-HGF)POF4-2171},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:001381298100001},
      doi          = {10.1088/1748-0221/19/11/C11015},
      url          = {https://juser.fz-juelich.de/record/1033925},
}