001034288 001__ 1034288
001034288 005__ 20250203103330.0
001034288 0247_ $$2datacite_doi$$a10.34734/FZJ-2024-07077
001034288 037__ $$aFZJ-2024-07077
001034288 1001_ $$0P:(DE-Juel1)194817$$aChekubasheva, Valeriia$$b0$$eCorresponding author$$ufzj
001034288 1112_ $$a12th International Conference "Nanotechnologies and Nanomaterials$$cUzhgorod$$d2024-08-21 - 2024-08-24$$gNano-2024$$wUkraine
001034288 245__ $$aA Frequency Tunable Whispering Gallery Mode Resonator for Study of Biological Liquids.
001034288 260__ $$c2024
001034288 300__ $$a35
001034288 3367_ $$2ORCID$$aCONFERENCE_PAPER
001034288 3367_ $$033$$2EndNote$$aConference Paper
001034288 3367_ $$2BibTeX$$aINPROCEEDINGS
001034288 3367_ $$2DRIVER$$aconferenceObject
001034288 3367_ $$2DataCite$$aOutput Types/Conference Paper
001034288 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1738054549_3100
001034288 520__ $$aIn recent years, nanotechnology and highly sensitive materials has been increasingly used to develop the devices allowing the study of various diseases. One of promising methods for measuring the concentrations of non-labeled biological substances is the whispering gallery mode (WGM) resonator technique [1] due to high sensitivity and non-contact detection. However, an additional advantage of this technique would be the possibility resonance frequency adjustment, which has not been reported in the literature.This work explores the application of 5CB and 1929 liquid crystals (LCs) for frequency tuning of WGM resonators targeted for accurate and sensitive analysis of bioliquids. The dielectric parameters of 5CB and 1929 LCs were measured in a wide frequency range, up to 40 GHz frequency. Dielectric constant and loss tangent are determined using special nomogram calibration procedure, plotted based on data obtained the simulation in COMSOL Multiphysics software and experiment. These data are important for understanding dielectric relaxation processes and times. The simulation process included introducing an additional absorbing dielectric layer filled with LCs and observing the changes in resonant frequencies. Since LCs have low dielectric losses, there is no significant effect on the Q-factor. However, LCs allow the resonant frequency to be effectively shifted to higher frequencies: Δf1 =85.8343 MHz for 5CB and Δf2 = 92.5473 MHz for 1929 LCs located parallel to the plane of the resonator.D.Z. greatly appreciates a research grant from the German National Academy of Sciences Leopoldina. V.C. is very grateful for the DAAD grant.(1)1. Gubin A.I., Barannik A.A., Protsenko I.A., Chekubasheva V.A., Lavrinovich A.A., Cherpak N.T., Vitusevich S. Microwave characterization of aqueous amino acid solutions using the multifrequency WGM resonator technique // Biological Chemistry.-2023.-404, N 2-3.-P. 229-235.
001034288 536__ $$0G:(DE-HGF)POF4-5241$$a5241 - Molecular Information Processing in Cellular Systems (POF4-524)$$cPOF4-524$$fPOF IV$$x0
001034288 7001_ $$0P:(DE-Juel1)194895$$aZhulai, Dmytro$$b1$$ufzj
001034288 7001_ $$0P:(DE-HGF)0$$aGubin$$b2
001034288 7001_ $$0P:(DE-HGF)0$$aCherpak$$b3
001034288 7001_ $$0P:(DE-HGF)0$$aKula$$b4
001034288 7001_ $$0P:(DE-Juel1)128738$$aVitusevich, Svetlana$$b5$$ufzj
001034288 8564_ $$uhttps://juser.fz-juelich.de/record/1034288/files/A%20Frequency%20Tunable%20Whispering%20Gallery%20Mode%20Resonator%20for%20Study%20of%20Biological%20Liquids.pdf$$yOpenAccess
001034288 909CO $$ooai:juser.fz-juelich.de:1034288$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
001034288 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)194817$$aForschungszentrum Jülich$$b0$$kFZJ
001034288 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)194895$$aForschungszentrum Jülich$$b1$$kFZJ
001034288 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128738$$aForschungszentrum Jülich$$b5$$kFZJ
001034288 9131_ $$0G:(DE-HGF)POF4-524$$1G:(DE-HGF)POF4-520$$2G:(DE-HGF)POF4-500$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-5241$$aDE-HGF$$bKey Technologies$$lNatural, Artificial and Cognitive Information Processing$$vMolecular and Cellular Information Processing$$x0
001034288 9141_ $$y2024
001034288 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
001034288 920__ $$lyes
001034288 9201_ $$0I:(DE-Juel1)IBI-3-20200312$$kIBI-3$$lBioelektronik$$x0
001034288 9801_ $$aFullTexts
001034288 980__ $$acontrib
001034288 980__ $$aVDB
001034288 980__ $$aUNRESTRICTED
001034288 980__ $$aI:(DE-Juel1)IBI-3-20200312