001034358 001__ 1034358
001034358 005__ 20250701125838.0
001034358 037__ $$aFZJ-2024-07141
001034358 041__ $$aEnglish
001034358 1001_ $$0P:(DE-Juel1)189036$$aGottschalk, Simon$$b0$$eCorresponding author$$ufzj
001034358 1112_ $$aAnnual European Rheology Conference 2024$$cLeeds$$d2024-04-09 - 2024-04-12$$gAERC2024$$wUK
001034358 245__ $$aIntroduction of New Rotational Mini-Rheometer for Scarce Sample
001034358 260__ $$c2024
001034358 3367_ $$033$$2EndNote$$aConference Paper
001034358 3367_ $$2DataCite$$aOther
001034358 3367_ $$2BibTeX$$aINPROCEEDINGS
001034358 3367_ $$2DRIVER$$aconferenceObject
001034358 3367_ $$2ORCID$$aLECTURE_SPEECH
001034358 3367_ $$0PUB:(DE-HGF)6$$2PUB:(DE-HGF)$$aConference Presentation$$bconf$$mconf$$s1734418633_31719$$xOther
001034358 520__ $$aWe introduce a miniaturized stress-controlled rheometer, aimed at enhancing rotational rheometry for analysis of scarce sample in material science and product development. This innovative device addresses the critical need for analyzing samples, such as biofilms, nascent drug formulations,and rare metal inks for microelectronics, which are typically limited in quantity due to their high production costs, challenging synthesis, or exclusive origins. Rheological measurements typically require at least 20 μl of sample material using commercial rotation rheometer, a requirement significantly reduced by our device. The mini-rheometer, approximately the size of a 50mm cube, utilizes in particular an air bearing rotor made of quartz glass, manufactured via Selective Laser Etching (SLE). This subtractive 3D printing method for glass ensures the precision needed e.g. for air bearing with μm-scale gaps. An outer magnetic field generated by two orthogonal coil pairs drives a centrally-placed magnet. Torque precision is maintained through applied current and the phase angle between inner and outer magnetic fields. The angular displacement is accurately gauged by two Hall effect sensors, that detect the rotational movement of the inner magnet. The mini-rheometer´s efficiency and functionality were tested performing a simple shear stress experiment on silicon reference oil. Notably, the employed cone-plate geometry only requires 2 μl of sample material, representing a significant advancement in sample conservation. This development extends the benefits of rotational rheometry - such as a wide range of strain rates and homogeneous strain profiles - to experiments where sample availability is limited. Due to the device´s miniaturized dimensions common, inverted microscopes could be used to study microstructural properties related to macroscopic flow behavior.
001034358 536__ $$0G:(DE-HGF)POF4-5352$$a5352 - Understanding the Functionality of Soft Matter and Biomolecular Systems (POF4-535)$$cPOF4-535$$fPOF IV$$x0
001034358 7001_ $$0P:(DE-Juel1)130797$$aLettinga, M.P.$$b1$$ufzj
001034358 7001_ $$0P:(DE-Juel1)133649$$aDahlhoff, Knut$$b2$$ufzj
001034358 7001_ $$0P:(DE-Juel1)142196$$aNatour, Ghaleb$$b3$$ufzj
001034358 8564_ $$uhttps://rheology-esr.org/index.php?rex_media_type=redactorImage&rex_media_file=aerc_abstracts_2024.pdf
001034358 909CO $$ooai:juser.fz-juelich.de:1034358$$pVDB
001034358 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)189036$$aForschungszentrum Jülich$$b0$$kFZJ
001034358 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)130797$$aForschungszentrum Jülich$$b1$$kFZJ
001034358 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)133649$$aForschungszentrum Jülich$$b2$$kFZJ
001034358 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)142196$$aForschungszentrum Jülich$$b3$$kFZJ
001034358 9131_ $$0G:(DE-HGF)POF4-535$$1G:(DE-HGF)POF4-530$$2G:(DE-HGF)POF4-500$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-5352$$aDE-HGF$$bKey Technologies$$lMaterials Systems Engineering$$vMaterials Information Discovery$$x0
001034358 9141_ $$y2024
001034358 920__ $$lyes
001034358 9201_ $$0I:(DE-Juel1)ZEA-1-20090406$$kZEA-1$$lZentralinstitut für Technologie$$x0
001034358 9201_ $$0I:(DE-Juel1)IBI-4-20200312$$kIBI-4$$lBiomakromolekulare Systeme und Prozesse$$x1
001034358 9201_ $$0I:(DE-Juel1)PGI-SO-20200511$$kPGI-SO$$lScience Office$$x2
001034358 980__ $$aconf
001034358 980__ $$aVDB
001034358 980__ $$aI:(DE-Juel1)ZEA-1-20090406
001034358 980__ $$aI:(DE-Juel1)IBI-4-20200312
001034358 980__ $$aI:(DE-Juel1)PGI-SO-20200511
001034358 980__ $$aUNRESTRICTED
001034358 981__ $$aI:(DE-Juel1)ITE-20250108