001     1038165
005     20250310131242.0
024 7 _ |a 10.1109/TIM.2025.3527590
|2 doi
024 7 _ |a 0018-9456
|2 ISSN
024 7 _ |a 0096-2260
|2 ISSN
024 7 _ |a 1557-9662
|2 ISSN
024 7 _ |a 2168-1902
|2 ISSN
024 7 _ |a 10.34734/FZJ-2025-01212
|2 datacite_doi
024 7 _ |a WOS:001410586700017
|2 WOS
037 _ _ |a FZJ-2025-01212
082 _ _ |a 620
100 1 _ |a Zimmer, Marcel
|0 P:(DE-Juel1)185033
|b 0
|e Corresponding author
245 _ _ |a Digital Twins for Building Pseudo-Measurements
260 _ _ |a New York, NY
|c 2025
|b IEEE
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1738855092_17463
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Building control architectures are strongly limited by the systematic lack of measurements at user-relevant locations. This paper proposes a digital twin architecture grounded in Correlated Gaussian Processes (Corr-GP) that provide information in the form of pseudo-measurements. Tested with thermal and CO2 measurements collected from the field, close-to-person pseudo-measurements are provided based on the continuous input of remotely located measurement signals. In particular, detailed short-term as well as long-term results are provided for both temperature and CO2 digital twins. We show that the proposed approach is trainable on only a few days of measurements. This property makes the proposed approach especially useful in field applications, where alternative algorithms, such as, for example, neural network architectures, are not capable of dealing with small amounts of data. We demonstrate how to adjust the proposed approach to provide temperature and CO2 digital twins for the generation of pseudo-measurements. Within the given framework, we show how to utilize the proposed digital twin to couple multiple reference sensors to provide close-to-person pseudo-measurements. By extending the Corr-GP approach to a non-zero prior mean formulation, we show how to reduce the included information by the reference sensors. More precisely, the extended approach can be defined as a digital twin with only a single reference sensor. This enables a reliable long-term application by avoiding the need for retraining caused by changing seasonalities within the signal characteristics. That is, we show that the digital twin trained in summer can be operated in winter.
536 _ _ |a 1122 - Design, Operation and Digitalization of the Future Energy Grids (POF4-112)
|0 G:(DE-HGF)POF4-1122
|c POF4-112
|f POF IV
|x 0
536 _ _ |a 1123 - Smart Areas and Research Platforms (POF4-112)
|0 G:(DE-HGF)POF4-1123
|c POF4-112
|f POF IV
|x 1
588 _ _ |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de
700 1 _ |a Buechel, Maximilian
|0 0009-0000-6346-2200
|b 1
700 1 _ |a Redder, Florian
|0 P:(DE-Juel1)177738
|b 2
700 1 _ |a Mork, Maximilian
|0 P:(DE-Juel1)174440
|b 3
700 1 _ |a Pesch, Thiemo
|0 P:(DE-Juel1)142000
|b 4
700 1 _ |a Xhonneux, André
|0 P:(DE-Juel1)8457
|b 5
700 1 _ |a Müller, Dirk
|0 P:(DE-Juel1)172026
|b 6
700 1 _ |a Benigni, Andrea
|0 P:(DE-Juel1)179029
|b 7
773 _ _ |a 10.1109/TIM.2025.3527590
|g p. 1 - 1
|0 PERI:(DE-600)2027532-8
|p 2504510
|t IEEE transactions on instrumentation and measurement
|v 74
|y 2025
|x 0018-9456
856 4 _ |u https://juser.fz-juelich.de/record/1038165/files/Invoice_APC600623349.pdf
856 4 _ |u https://juser.fz-juelich.de/record/1038165/files/Digital_Twins_for_Building_Pseudo-Measurements-2.pdf
|y OpenAccess
909 C O |o oai:juser.fz-juelich.de:1038165
|p openaire
|p open_access
|p OpenAPC
|p driver
|p VDB
|p openCost
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)185033
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 0009-0000-6346-2200
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)177738
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)174440
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)142000
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 5
|6 P:(DE-Juel1)8457
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)172026
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 7
|6 P:(DE-Juel1)179029
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Energiesystemdesign (ESD)
|1 G:(DE-HGF)POF4-110
|0 G:(DE-HGF)POF4-112
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Digitalisierung und Systemtechnik
|9 G:(DE-HGF)POF4-1122
|x 0
913 1 _ |a DE-HGF
|b Forschungsbereich Energie
|l Energiesystemdesign (ESD)
|1 G:(DE-HGF)POF4-110
|0 G:(DE-HGF)POF4-112
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-100
|4 G:(DE-HGF)POF
|v Digitalisierung und Systemtechnik
|9 G:(DE-HGF)POF4-1123
|x 1
914 1 _ |y 2025
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2025-01-06
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2025-01-06
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1160
|2 StatID
|b Current Contents - Engineering, Computing and Technology
|d 2025-01-06
915 _ _ |a Creative Commons Attribution CC BY 4.0
|0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0600
|2 StatID
|b Ebsco Academic Search
|d 2025-01-06
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b IEEE T INSTRUM MEAS : 2022
|d 2025-01-06
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2025-01-06
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2025-01-06
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b ASC
|d 2025-01-06
915 _ _ |a IF >= 5
|0 StatID:(DE-HGF)9905
|2 StatID
|b IEEE T INSTRUM MEAS : 2022
|d 2025-01-06
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2025-01-06
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2025-01-06
915 p c |a APC keys set
|2 APC
|0 PC:(DE-HGF)0000
915 p c |a Local Funding
|2 APC
|0 PC:(DE-HGF)0001
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)ICE-1-20170217
|k ICE-1
|l Modellierung von Energiesystemen
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)ICE-1-20170217
980 _ _ |a APC
980 _ _ |a UNRESTRICTED
980 1 _ |a APC
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor