001     1040923
005     20251027132711.0
024 7 _ |a 10.1007/s10877-025-01279-x
|2 doi
024 7 _ |a 0748-1977
|2 ISSN
024 7 _ |a 1387-1307
|2 ISSN
024 7 _ |a 1573-2614
|2 ISSN
024 7 _ |a 2214-7330
|2 ISSN
024 7 _ |a 10.34734/FZJ-2025-02053
|2 datacite_doi
024 7 _ |a 40100556
|2 pmid
024 7 _ |a WOS:001448808900001
|2 WOS
037 _ _ |a FZJ-2025-02053
082 _ _ |a 610
100 1 _ |a Breteler, Martine J. M.
|0 P:(DE-HGF)0
|b 0
|e Corresponding author
245 _ _ |a Reliability of an all-in-one wearable sensor for continuous vital signs monitoring in high-risk patients: the NIGHTINGALE clinical validation study
260 _ _ |a Dordrecht [u.a.]
|c 2025
|b Springer Science + Business Media B.V.
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1761285457_32378
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Continuous vital signs monitoring with wearable systems may improve early recognition of patient deterioration on hospital wards. The objective of this study was to determine whether the wearable Checkpoint Cardio’s CPC12S, can accurately measure heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), blood pressure (BP) and temperature continuously. In an observational multicenter method comparison study of 70 high-risk surgical patients admitted to high-dependency wards; HR, RR, SpO2, BP and temperature were simultaneously measured with the CPC12S system and with ICU-grade monitoring systems in four European hospitals. Outcome measures were bias and 95% limits of agreement (LoA). Clinical accuracy was assessed with Clarke Error Grid analyses for HR and RR. A total of 3,212 h of vital signs data (on average 26 h per patient) were analyzed. For HR, bias (95% LoA) of the pooled analysis was 0.0 (-3.5 to 3.4), for RR 1.5 (-3.7 to 7.5) and for SpO2 0.4 (-3.1 to 4.0). The CPC12S system overestimated BP, with a bias of 8.9 and wide LoA (-23.3 to 41.2). Temperature was underestimated with a bias of -0.6 and LoA of -1.7 to 0.6. Clarke Error Grid analyses showed that adequate treatment decisions regarding changes in HR and RR would have been made in 99.2% and 92.0% of cases respectively. The CPC12S system showed high accuracy for measurements of HR. The accuracy of RR, SpO2 were slightly overestimated and core temperature underestimated, with LoA outside the predefined clinical acceptable range. The accuracy of BP was unacceptably low.
536 _ _ |a 5112 - Cross-Domain Algorithms, Tools, Methods Labs (ATMLs) and Research Groups (POF4-511)
|0 G:(DE-HGF)POF4-5112
|c POF4-511
|f POF IV
|x 0
536 _ _ |a SDI-S - SDI-S: Smart Data Innovation Services - Experimentelle Erprobung und Entwicklung von KI-Dienstverbünden für Innovationen auf industriellen Daten (01IS22095D)
|0 G:(BMBF)01IS22095D
|c 01IS22095D
|x 1
536 _ _ |a NIGHTINGALE - Connecting Patients and Carers using wearable sensor technology (727534)
|0 G:(EU-Grant)727534
|c 727534
|f H2020-SC1-2016-CNECT
|x 2
588 _ _ |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de
700 1 _ |a Leigard, Ellen
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Hartung, Lisa C.
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Welch, John R.
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Brealey, David A.
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Fritsch, Sebastian J.
|0 P:(DE-Juel1)185651
|b 5
|u fzj
700 1 _ |a Konrad, David
|0 P:(DE-HGF)0
|b 6
700 1 _ |a Hertzberg, Daniel
|0 P:(DE-HGF)0
|b 7
700 1 _ |a Bell, Max
|0 P:(DE-HGF)0
|b 8
700 1 _ |a Rienstra, Heleen
|0 P:(DE-HGF)0
|b 9
700 1 _ |a Rademakers, Frank E.
|0 P:(DE-HGF)0
|b 10
700 1 _ |a Kalkman, Cor J.
|0 P:(DE-HGF)0
|b 11
773 _ _ |a 10.1007/s10877-025-01279-x
|0 PERI:(DE-600)2010139-9
|p 1087–1100
|t Journal of clinical monitoring and computing
|v 39
|y 2025
|x 0748-1977
856 4 _ |u https://juser.fz-juelich.de/record/1040923/files/Main%20document.pdf
|y OpenAccess
909 C O |o oai:juser.fz-juelich.de:1040923
|p openaire
|p open_access
|p driver
|p VDB
|p ec_fundedresources
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 5
|6 P:(DE-Juel1)185651
913 1 _ |a DE-HGF
|b Key Technologies
|l Engineering Digital Futures – Supercomputing, Data Management and Information Security for Knowledge and Action
|1 G:(DE-HGF)POF4-510
|0 G:(DE-HGF)POF4-511
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-500
|4 G:(DE-HGF)POF
|v Enabling Computational- & Data-Intensive Science and Engineering
|9 G:(DE-HGF)POF4-5112
|x 0
914 1 _ |y 2025
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2024-12-19
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2024-12-19
915 _ _ |a Creative Commons Attribution CC BY 4.0
|0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2024-12-19
915 _ _ |a DEAL Springer
|0 StatID:(DE-HGF)3002
|2 StatID
|d 2024-12-19
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2024-12-19
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2024-12-19
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
|d 2024-12-19
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
|d 2024-12-19
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2024-12-19
920 _ _ |l no
920 1 _ |0 I:(DE-Juel1)JSC-20090406
|k JSC
|l Jülich Supercomputing Center
|x 0
920 1 _ |0 I:(DE-Juel1)CASA-20230315
|k CASA
|l Center for Advanced Simulation and Analytics
|x 1
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)JSC-20090406
980 _ _ |a I:(DE-Juel1)CASA-20230315
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21