001     1043249
005     20250930132704.0
024 7 _ |a 10.1002/mp.17890
|2 doi
024 7 _ |a 0094-2405
|2 ISSN
024 7 _ |a 1522-8541
|2 ISSN
024 7 _ |a 2473-4209
|2 ISSN
024 7 _ |a 10.34734/FZJ-2025-02799
|2 datacite_doi
024 7 _ |a 40387059
|2 pmid
024 7 _ |a WOS:001490137600001
|2 WOS
037 _ _ |a FZJ-2025-02799
082 _ _ |a 610
100 1 _ |a Hong, Suk-Min
|0 P:(DE-Juel1)164150
|b 0
|e Corresponding author
245 _ _ |a Novel 1 H/ 19 F double‐tuned coil using an asymmetrical butterfly coil
260 _ _ |a Hoboken, NJ
|c 2025
|b Wiley
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1756896949_18417
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Background: Fluorine-19 (19F) magnetic resonance imaging (MRI) is a non-invasive imaging tool for the targeted application of fluorinated agents, such as cell tracking, and for the demonstration of oximetry. However, as the SNR of 19F is significantly weaker than that of proton (1H) imaging, the 19F coil must be combined with 1H coils for anatomical co-registration and B0 shimming. This is difficult due to the strong coupling between the coils when they are in proximity, and is problematic since the Larmor frequency of 19F is 94% that of 1H, further increasing the potential for coupling between the 1H and 19F elements.Purpose: Conventional double-tuned coil methods tend to generate loss compared to single-tuned reference coils. The asymmetrical butterfly coil has a split resonance peak, which can cover frequencies of 1H and 19F without losses arising from lossy traps or switching circuits. In this study, the use of an asymmetrical butterfly coil was evaluated for 1H/19F applications.Methods: To increase quadrature efficiency at both the 1H and 19F frequencies, the left and right loops of the butterfly coil were tuned asymmetrically. The coil's tuning and performance were evaluated in simulations and MR measurements, and the results were compared to a dimension-matched single-tuned loop coil.Results: The split resonance peak of the asymmetrical butterfly coil successfully spanned the 19F to 1H frequency. It operated with higher quadrature efficiency at both 1H and 19F frequencies and demonstrated superior receive sensitivity and SNR compared to the dimension-matched single-tuned loop coil.Conclusions: The split resonance peak of the asymmetrical butterfly coil supported both 1H and 19F frequencies, delivering a higher SNR than that of the single-tuned loop coil. Since the asymmetrical butterfly coil can cover ¹H and ¹⁹F frequencies without loss and provides higher efficiency than the reference single-tuned coil, it can be effectively utilized for ¹H/¹⁹F MRI applications.
536 _ _ |a 5253 - Neuroimaging (POF4-525)
|0 G:(DE-HGF)POF4-5253
|c POF4-525
|f POF IV
|x 0
536 _ _ |a DFG project G:(GEPRIS)491111487 - Open-Access-Publikationskosten / 2025 - 2027 / Forschungszentrum Jülich (OAPKFZJ) (491111487)
|0 G:(GEPRIS)491111487
|c 491111487
|x 1
588 _ _ |a Dataset connected to CrossRef, Journals: juser.fz-juelich.de
700 1 _ |a Choi, Chang-Hoon
|0 P:(DE-Juel1)164356
|b 1
700 1 _ |a Felder, Jörg
|0 P:(DE-Juel1)131761
|b 2
700 1 _ |a Shah, N. Jon
|0 P:(DE-Juel1)131794
|b 3
|e Corresponding author
773 _ _ |a 10.1002/mp.17890
|g p. mp.17890
|0 PERI:(DE-600)1466421-5
|n 7
|p 17890
|t Medical physics
|v 52
|y 2025
|x 0094-2405
856 4 _ |u https://juser.fz-juelich.de/record/1043249/files/Invoice_2736229.pdf
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/1043249/files/Medical%20Physics%20-%202025%20-%20Hong%20-%20Novel%201H%2019F%20double%E2%80%90tuned%20coil%20using%20an%20asymmetrical%20butterfly%20coil.pdf
909 C O |o oai:juser.fz-juelich.de:1043249
|p openaire
|p open_access
|p OpenAPC
|p OpenAPC_DEAL
|p driver
|p VDB
|p openCost
|p dnbdelivery
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)164150
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)164356
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)131761
910 1 _ |a Forschungszentrum Jülich
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)131794
913 1 _ |a DE-HGF
|b Key Technologies
|l Natural, Artificial and Cognitive Information Processing
|1 G:(DE-HGF)POF4-520
|0 G:(DE-HGF)POF4-525
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-500
|4 G:(DE-HGF)POF
|v Decoding Brain Organization and Dysfunction
|9 G:(DE-HGF)POF4-5253
|x 0
914 1 _ |y 2025
915 p c |a APC keys set
|0 PC:(DE-HGF)0000
|2 APC
915 p c |a Local Funding
|0 PC:(DE-HGF)0001
|2 APC
915 p c |a DFG OA Publikationskosten
|0 PC:(DE-HGF)0002
|2 APC
915 p c |a DEAL: Wiley 2019
|0 PC:(DE-HGF)0120
|2 APC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
|d 2024-12-13
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
|d 2024-12-13
915 _ _ |a Creative Commons Attribution CC BY 4.0
|0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0600
|2 StatID
|b Ebsco Academic Search
|d 2024-12-13
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b MED PHYS : 2022
|d 2024-12-13
915 _ _ |a DEAL Wiley
|0 StatID:(DE-HGF)3001
|2 StatID
|d 2024-12-13
|w ger
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1030
|2 StatID
|b Current Contents - Life Sciences
|d 2024-12-13
915 _ _ |a WoS
|0 StatID:(DE-HGF)0113
|2 StatID
|b Science Citation Index Expanded
|d 2024-12-13
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
|d 2024-12-13
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
|d 2024-12-13
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a Peer Review
|0 StatID:(DE-HGF)0030
|2 StatID
|b ASC
|d 2024-12-13
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0160
|2 StatID
|b Essential Science Indicators
|d 2024-12-13
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1110
|2 StatID
|b Current Contents - Clinical Medicine
|d 2024-12-13
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Clarivate Analytics Master Journal List
|d 2024-12-13
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)INM-4-20090406
|k INM-4
|l Physik der Medizinischen Bildgebung
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)INM-4-20090406
980 _ _ |a APC
980 1 _ |a APC
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21