%0 Journal Article
%A Abbas, Mohamad Bilal
%A Pourshahidi, Ali Mohammad
%A Krause, Hans-Joachim
%A Engelmann, Ulrich
%T How MNP respond to dual-frequency magnetic excitation in viscous mediaInternational Journal on Magnetic Particle Imaging IJMPI
%J International journal on magnetic particle imaging
%V 11
%N 1
%@ 2365-9033
%C Lübeck
%I Infinite Science Publishing
%M FZJ-2025-03873
%P 2503033
%D 2025
%X Magnetic nanoparticles (MNP) enable new biomedical applications as imaging tracers, heating agents or biosensors due to their unique relaxation mechanism in alternating magnetic fields. For assessing MNP suitable for such applications, magnetic particle spectroscopy (MPS) offers a reliable method, dual-frequency excitation adding sensitivity. Biomedical applications, however, rely on MNP use in physiological environments (blood, tissue, etc.) of various viscosities, which could strongly alter the MNP relaxation behavior. In this work, we present our preliminary results of varying viscosity on the relaxation of MNP during dual-frequency MPS, studied with micromagnetic dynamic magnetization simulation.
%B International Workshop on Magnetic Particle Imaging
%C 17 Mar 2025 - 19 Mar 2025, Lübeck (Germany)
Y2 17 Mar 2025 - 19 Mar 2025
M2 Lübeck, Germany
%K computational modeling (Other)
%K Frequency Mixing Magnetic Detection (Other)
%K viscosity (Other)
%K Particle size (Other)
%K Magnetic Particle Spectroscopy (MPS) (Other)
%K Magnetic relaxation (Other)
%K dual-frequency (Other)
%F PUB:(DE-HGF)8 ; PUB:(DE-HGF)16
%9 Contribution to a conference proceedingsJournal Article
%R 10.18416/IJMPI.2025.2503033
%U https://juser.fz-juelich.de/record/1046563