Preprint FZJ-2025-04143

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Benchmarking Orientation Distribution Function Estimation Methods for Tractometry in Single-Shell Diffusion Magnetic Resonance Imaging - An Evaluation of Test-Retest Reliability and Predictive Capability

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2025
Cold Spring Harbor Laboratory, NY Cold Spring Harbor

bioRxiv beta () [10.1101/2025.09.02.673635]

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: Deriving white matter (WM) bundles in-vivo has thus far mainly been applied in research settings, leveraging high angular resolution, multi-shell diffusion MRI (dMRI) acquisitions that enable advanced reconstruction methods. However, these advanced acquisitions are both time-consuming and costly to acquire. The ability to reconstruct WM bundles in the massive amounts of existing single-shelled, lower angular resolution data from legacy research studies and healthcare systems would offer much broader clinical applications and population-level generalizability. While legacy scans may offer a valuable, large-scale complement to contemporary research datasets, the reliability of white matter bundles derived from these scans remains unclear. Here, we leverage a large research dataset where each 64-direction dMRI scan was acquired as two independent 32-direction runs per subject. To investigate how recently developed bundle segmentation methods generalize to this data, we evaluated the test-retest reliability of the two 32-direction scans, of WM bundle extraction across three orientation distribution function (ODF) reconstruction methods: generalized q-sampling imaging (GQI), constrained spherical deconvolution (CSD), and single-shell three-tissue CSD (SS3T). We found that the majority of WM bundles could be reliably extracted from dMRI scans that were acquired using the 32-direction, single-shell acquisition scheme. The mean dice coefficient of reconstructed WM bundles was consistently higher within-subject than between-subject for all WM bundles and ODF reconstruction methods, illustrating preservation of person-specific anatomy. Further, when using features of the bundles to predict complex reasoning assessed using a computerized cognitive battery, we observed stable prediction accuracies ( r : 0.15-0.36) across the test-retest data. Among the three ODF reconstruction methods, SS3T had a good balance between sensitivity and specificity in external validation, a high intra-class correlation of extracted features, more plausible bundles, and strong predictive performance. More broadly, these results demonstrate that bundle segmentation can achieve robust performance even on lower angular resolution, single-shell dMRI, with particular advantages for ODF methods optimized for single-shell data. This highlights the considerable potential for dMRI collected in healthcare settings and legacy research datasets to accelerate and expand the scope of WM research.

Classification:

Contributing Institute(s):
  1. Gehirn & Verhalten (INM-7)
Research Program(s):
  1. 5253 - Neuroimaging (POF4-525) (POF4-525)

Appears in the scientific report 2025
Click to display QR Code for this record

The record appears in these collections:
Institute Collections > INM > INM-7
Document types > Reports > Preprints
Workflow collections > Public records
Publications database

 Record created 2025-10-14, last modified 2025-11-10


Restricted:
Download fulltext DOCX
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)