001049200 001__ 1049200
001049200 005__ 20251211202159.0
001049200 0247_ $$2doi$$a10.1109/TIM.2025.3561427
001049200 0247_ $$2ISSN$$a0018-9456
001049200 0247_ $$2ISSN$$a0096-2260
001049200 0247_ $$2ISSN$$a1557-9662
001049200 0247_ $$2ISSN$$a2168-1902
001049200 0247_ $$2datacite_doi$$a10.34734/FZJ-2025-05282
001049200 037__ $$aFZJ-2025-05282
001049200 041__ $$aEnglish
001049200 082__ $$a620
001049200 1001_ $$0P:(DE-HGF)0$$aPegoraro, Paolo Attilio$$b0$$eCorresponding author
001049200 245__ $$aImproved Fault Detection and Location Method in Three-Phase Distribution Networks Leveraging Traceable PMU Measurements
001049200 260__ $$aNew York, NY$$bIEEE$$c2025
001049200 3367_ $$2DRIVER$$aarticle
001049200 3367_ $$2DataCite$$aOutput Types/Journal article
001049200 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1765464521_29138
001049200 3367_ $$2BibTeX$$aARTICLE
001049200 3367_ $$2ORCID$$aJOURNAL_ARTICLE
001049200 3367_ $$00$$2EndNote$$aJournal Article
001049200 520__ $$aSeveral fault detection methods and location algorithms in the literature are founded on state estimation (SE). In recent approaches, in most cases, the SE process is performed based on synchronized measurements provided by phasor measurement units (PMUs). However, coupling fault identification with phasor measurements is a challenging task, which can present several risks. Particularly, in dynamic scenarios related to faults, the traceability of the measurements could be compromised. This article, relying on dynamics detection policies to evaluate at run time measurements applicability, proposes a novel fault detection and location method based on PMU measurements, which improves both correct location rate and location speed, thanks to a more robust definition of detection indicators and of the needed thresholds. Using only traceable measurements, decision risks can be reduced in a few PMU reporting intervals. The validity of the proposed approach is confirmed by the simulations carried out by means of a real-time digital simulator (RTDS) on a three-phase CIGRE European Medium Voltage (MV) distribution network in different fault configurations and measurement scenarios.
001049200 536__ $$0G:(DE-HGF)POF4-1121$$a1121 - Digitalization and Systems Technology for Flexibility Solutions (POF4-112)$$cPOF4-112$$fPOF IV$$x0
001049200 536__ $$0G:(DE-HGF)POF4-1122$$a1122 - Design, Operation and Digitalization of the Future Energy Grids (POF4-112)$$cPOF4-112$$fPOF IV$$x1
001049200 536__ $$0G:(DE-HGF)POF4-1123$$a1123 - Smart Areas and Research Platforms (POF4-112)$$cPOF4-112$$fPOF IV$$x2
001049200 588__ $$aDataset connected to CrossRef, Journals: juser.fz-juelich.de
001049200 7001_ $$0P:(DE-HGF)0$$aSitzia, Carlo$$b1
001049200 7001_ $$0P:(DE-HGF)0$$aSolinas, Antonio Vincenzo$$b2
001049200 7001_ $$0P:(DE-HGF)0$$aSulis, Sara$$b3
001049200 7001_ $$0P:(DE-Juel1)186779$$aCarta, Daniele$$b4
001049200 7001_ $$0P:(DE-Juel1)179029$$aBenigni, Andrea$$b5$$ufzj
001049200 773__ $$0PERI:(DE-600)2027532-8$$a10.1109/TIM.2025.3561427$$gVol. 74, p. 1 - 12$$p1 - 12$$tIEEE transactions on instrumentation and measurement$$v74$$x0018-9456$$y2025
001049200 8564_ $$uhttps://juser.fz-juelich.de/record/1049200/files/Improved_Fault_Detection_and_Location_Method_in_Three-Phase_Distribution_Networks_Leveraging_Traceable_PMU_Measurements.pdf$$yOpenAccess
001049200 909CO $$ooai:juser.fz-juelich.de:1049200$$popenaire$$popen_access$$pVDB$$pdriver$$pdnbdelivery
001049200 9101_ $$0I:(DE-HGF)0$$6P:(DE-HGF)0$$aUniversity of Cagliari$$b0
001049200 9101_ $$0I:(DE-HGF)0$$6P:(DE-HGF)0$$a University of Cagliari$$b1
001049200 9101_ $$0I:(DE-HGF)0$$6P:(DE-HGF)0$$a University of Cagliari$$b2
001049200 9101_ $$0I:(DE-HGF)0$$6P:(DE-HGF)0$$a University of Cagliari$$b3
001049200 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)186779$$aForschungszentrum Jülich$$b4$$kFZJ
001049200 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)179029$$aForschungszentrum Jülich$$b5$$kFZJ
001049200 9131_ $$0G:(DE-HGF)POF4-112$$1G:(DE-HGF)POF4-110$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1121$$aDE-HGF$$bForschungsbereich Energie$$lEnergiesystemdesign (ESD)$$vDigitalisierung und Systemtechnik$$x0
001049200 9131_ $$0G:(DE-HGF)POF4-112$$1G:(DE-HGF)POF4-110$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1122$$aDE-HGF$$bForschungsbereich Energie$$lEnergiesystemdesign (ESD)$$vDigitalisierung und Systemtechnik$$x1
001049200 9131_ $$0G:(DE-HGF)POF4-112$$1G:(DE-HGF)POF4-110$$2G:(DE-HGF)POF4-100$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF4-1123$$aDE-HGF$$bForschungsbereich Energie$$lEnergiesystemdesign (ESD)$$vDigitalisierung und Systemtechnik$$x2
001049200 9141_ $$y2025
001049200 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2025-01-06
001049200 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
001049200 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bIEEE T INSTRUM MEAS : 2022$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
001049200 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)9905$$2StatID$$aIF >= 5$$bIEEE T INSTRUM MEAS : 2022$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2025-01-06
001049200 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2025-01-06
001049200 920__ $$lno
001049200 9201_ $$0I:(DE-Juel1)ICE-1-20170217$$kICE-1$$lModellierung von Energiesystemen$$x0
001049200 980__ $$ajournal
001049200 980__ $$aVDB
001049200 980__ $$aUNRESTRICTED
001049200 980__ $$aI:(DE-Juel1)ICE-1-20170217
001049200 9801_ $$aFullTexts