TY  - CONF
AU  - Halama, Arthur
AU  - Kamerdzhiev, Vsevolod
AU  - Koch, Günther
AU  - Böhme, Christian
TI  - Results of HESR BPM Testing
PB  - JACoW Publishing
M1  - FZJ-2026-00797
SP  - 615-618
PY  - 2026
AB  - For the HESR diagonally cut BPMs were designed, with 64 manufactured and tested with a purpose-built BPM test-stand. This test-stand had to host BPMs of various lengths, the overall length of the complete vacuum system varies from 450 mm to 1585 mm. For all BPMs several properties, e.g. the geometric factors or the electrical center in relation to the geometric center, were measured utilizing the test stand. The results of these measurements will be presented together with the challenges resulting from the design choices made for the layout of the test stand.
T2  - 14th International Beam Instrumentation Conference
CY  - 7 Sep 2025 - 11 Sep 2025, Liverpool (UK)
Y2  - 7 Sep 2025 - 11 Sep 2025
M2  - Liverpool, UK
KW  - Accelerator Physics (Other)
KW  - MC03 - MC03: Beam Position Monitors (Other)
LB  - PUB:(DE-HGF)8
DO  - DOI:10.18429/jacow-ibic2025-wepco03
UR  - https://juser.fz-juelich.de/record/1052159
ER  -