abstract = {For the HESR diagonally cut BPMs were designed, with 64
manufactured and tested with a purpose-built BPM test-stand.
This test-stand had to host BPMs of various lengths, the
overall length of the complete vacuum system varies from 450
mm to 1585 mm. For all BPMs several properties, e.g. the
geometric factors or the electrical center in relation to
the geometric center, were measured utilizing the test
stand. The results of these measurements will be presented
together with the challenges resulting from the design
choices made for the layout of the test stand.},