@INPROCEEDINGS{Schrader:1053103,
      author       = {Schrader, Tobias Erich and Jialian, He},
      othercontributors = {Konik, Peter},
      title        = {{D}evelopment of a new {M}acromolecular {I}nstrument at the
                      {H}igh {B}rilliance {N}eutron {S}ource in {J}ülich},
      reportid     = {FZJ-2026-01443},
      year         = {2025},
      abstract     = {Neutron protein crystallography requires a highly brilliant
                      beam in order to measure very small biological single
                      crystals, which typically measure between 0.01 and 1 mm³.
                      Additionally, these crystals have a large unit cell size,
                      which may be as large as 200 Å in at least one dimension.
                      This makes it challenging for neutron beamlines to
                      accommodate this type of measurement. The Jülich High
                      Brilliance Neutron Source is a potential future source of
                      neutrons for Germany. As part of this project, the design
                      and simulation of a macromolecular diffractometer at the 24
                      Hz TMR station with a conventional 80 m long neutron guide
                      using a cold moderator is planned. An optimized elliptical
                      guide was developed for a neutron bandwidth of 2-4 Å.
                      Simulations suggest that the 80 m instrument will have a
                      flux of 3.3×106 n/s/cm² and a brilliance transfer of
                      $91.7\%$ within a divergence of ±0.4°. Furthermore, it is
                      proposed that the diameter of the smallest moderator should
                      be 14 mm.},
      month         = {Dec},
      date          = {2025-12-03},
      organization  = {MLZ User Meeting 2025, München
                       (Germany), 3 Dec 2025 - 4 Dec 2025},
      subtyp        = {After Call},
      cin          = {JCNS-4 / JCNS-FRM-II / MLZ},
      cid          = {I:(DE-Juel1)JCNS-4-20201012 /
                      I:(DE-Juel1)JCNS-FRM-II-20110218 / I:(DE-588b)4597118-3},
      pnm          = {6G4 - Jülich Centre for Neutron Research (JCNS) (FZJ)
                      (POF4-6G4) / 632 - Materials – Quantum, Complex and
                      Functional Materials (POF4-632)},
      pid          = {G:(DE-HGF)POF4-6G4 / G:(DE-HGF)POF4-632},
      experiment   = {EXP:(DE-MLZ)BIODIFF-20140101},
      typ          = {PUB:(DE-HGF)24},
      url          = {https://juser.fz-juelich.de/record/1053103},
}