001     11921
005     20180208220844.0
024 7 _ |2 DOI
|a 10.1039/c0ja00055h
024 7 _ |2 WOS
|a WOS:000283150100011
037 _ _ |a PreJuSER-11921
041 _ _ |a eng
082 _ _ |a 540
084 _ _ |2 WoS
|a Chemistry, Analytical
084 _ _ |2 WoS
|a Spectroscopy
100 1 _ |a Pozebon, D.
|b 0
|0 P:(DE-HGF)0
245 _ _ |a Bioimaging of metals in thin mouse brain section by laser ablation inductively coupled plamsa mass spectrometry: novel online quantification strategy using aqueous standards
260 _ _ |a Cambridge
|b ChemSoc
|c 2010
300 _ _ |a 1739 - 1744
336 7 _ |a Journal Article
|0 PUB:(DE-HGF)16
|2 PUB:(DE-HGF)
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|0 0
|2 EndNote
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a article
|2 DRIVER
440 _ 0 |a Journal of Analytical Atomic Spectrometry
|x 0267-9477
|0 3023
|y 11
|v 25
500 _ _ |a Dirce Pozebon would like to thank CAPES (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior) for financial support. The authors thank Jurgen Srega and Meike Hamester (Thermo Fisher Scientific) for instrumental support of new BrainMet (BrainMet-Bioimaging of Metals and Metallomics) laboratory at Research Centre Juelich (www.brainmet.com).
520 _ _ |a A novel solution-based calibration method for quantitative spatial resolved distribution analysis (imaging) of elements in thin biological tissue sections by LA-ICP-MS (laser ablation inductively coupled plasma mass spectrometry) is described. A dual flow of the carrier and nebulizer gas is used to transport the aerosol of the laser ablated solid sample (brain tissue) and that of the nebulized aqueous standard into inductively coupled plasma (ICP) source, respectively. Both aerosols are introduced separately in the injector tube inside a special ICP torch and then mixed in the inductively coupled plasma. Calibration curves were obtained via two different calibration strategies: (i) solution based calibration and (ii) with a set of well characterized homogeneous brain laboratory standards. In the first approach matrix matching is performed by solution nebulization of a series of aqueous standards with defined analyte concentrations and simultaneous laser ablation of brain homogenate followed by nebulization of 2% (v/v) HNO3 and laser ablation of a whole brain slice (line by line). In the second approach of calibration a set of brain homogenates with defined analyte concentrations is analyzed by LA-ICP-MS followed by the imaging of brain tissue under the same experimental conditions (dry plasma). Calibration curves of elements of interest (e. g., Li, Na, Al, K, Ca, Ti, V, Mn, Ni, Co, Cr, Cu, Zn, As, Se, Rb, Sr, Y, Cd, Ba, La, Ce, Nd, Gd, Hg, Pb, Bi and U) were obtained using (i) aqueous standards or (ii) the set of synthetic laboratory standards prepared from a mouse brain homogenate doped with elements at defined concentrations. The ratio of the slope of the calibration curves (obtained by using aqueous standards and solid standards) was applied to correct the differences of sensitivity among ICP-MS and LA-ICP-MS. Quantitative images of Li, Mn, Fe, Cu, Zn and Rb in mouse brain were obtained under wet plasma condition (nebulization of HNO3 solution in parallel with ablation of solid brain sample).
536 _ _ |a Funktion und Dysfunktion des Nervensystems
|c P33
|2 G:(DE-HGF)
|0 G:(DE-Juel1)FUEK409
|x 0
588 _ _ |a Dataset connected to Web of Science
650 _ 7 |a J
|2 WoSType
700 1 _ |a Dressler, V.L.
|b 1
|0 P:(DE-HGF)0
700 1 _ |a Mesko, M.F.
|b 2
|0 P:(DE-HGF)0
700 1 _ |a Matusch, A.
|b 3
|u FZJ
|0 P:(DE-Juel1)138474
700 1 _ |a Becker, J. S.
|b 4
|u FZJ
|0 P:(DE-Juel1)VDB2662
773 _ _ |a 10.1039/c0ja00055h
|g Vol. 25, p. 1739 - 1744
|p 1739 - 1744
|q 25<1739 - 1744
|0 PERI:(DE-600)1484654-8
|t Journal of analytical atomic spectrometry
|v 25
|y 2010
|x 0267-9477
856 7 _ |u http://dx.doi.org/10.1039/c0ja00055h
909 C O |o oai:juser.fz-juelich.de:11921
|p VDB
913 1 _ |k P33
|v Funktion und Dysfunktion des Nervensystems
|l Funktion und Dysfunktion des Nervensystems
|b Gesundheit
|0 G:(DE-Juel1)FUEK409
|x 0
914 1 _ |y 2010
915 _ _ |0 StatID:(DE-HGF)0010
|a JCR/ISI refereed
920 1 _ |k INM-2
|l Molekulare Organisation des Gehirns
|g INM
|0 I:(DE-Juel1)INM-2-20090406
|x 0
920 1 _ |k ZCH
|l Zentralabteilung für Chemische Analysen
|g ZCH
|0 I:(DE-Juel1)ZCH-20090406
|x 1
970 _ _ |a VDB:(DE-Juel1)123316
980 _ _ |a VDB
980 _ _ |a ConvertedRecord
980 _ _ |a journal
980 _ _ |a I:(DE-Juel1)INM-2-20090406
980 _ _ |a I:(DE-Juel1)ZEA-3-20090406
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)ZEA-3-20090406
981 _ _ |a I:(DE-Juel1)ZCH-20090406


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21