TY  - JOUR
AU  - Supra, J.
AU  - Janßen, H.
AU  - Lehnert, W.
AU  - Stolten, D.
TI  - Temperature distribution in a liquid-cooled HT-PEFC stack
JO  - International journal of hydrogen energy
VL  - 38
IS  - 4
SN  - 0360-3199
CY  - New York, NY [u.a.]
PB  - Elsevier
M1  - FZJ-2013-01783
SP  - 1943 - 1951
PY  - 2013
AB  - A liquid (heat transfer oil) cooling system for high temperature polymer electrolyte fuel cell (HT-PEFC) stacks in the power range above 1 kWel using encapsulated cooling cells was designed. Calculations showed that it is sufficient to cool every third cell to maintain an operating temperature of about 160 °C. An HT-PEFC stack module including 12 cells with an active area of 320 cm2 each was assembled and tested experimentally regarding the temperature distribution from cell to cell. It was found that sufficient cooling with an oil inlet temperature of 160 °C is guaranteed up to a current density of 450 mA/cm2 when operated with synthetic reformate (42% H2, 57% N2, 1% CO). At this current density, the maximum temperature difference from cell to cell does not exceed 8.3 K. Additionally, this cooling system provided enhanced protection against leaks.
LB  - PUB:(DE-HGF)16
UR  - <Go to ISI:>//WOS:000314860600022
DO  - DOI:10.1016/j.ijhydene.2012.10.093
UR  - https://juser.fz-juelich.de/record/133246
ER  -