% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@PHDTHESIS{Tokariev:133740,
author = {Tokariev, Oleg A.},
title = {{M}icro- and {M}acro-{M}echanical {T}esting of
{T}ransparent {M}g{A}l$_{2}${O}$_{4}$ {S}pinel},
volume = {215},
school = {RWTH Aachen},
type = {Dr.},
address = {Jülich},
publisher = {Forschungszentrum Jülich GmbH Zentralbibliothek, Verlag},
reportid = {FZJ-2013-02139},
isbn = {978-3-89336-960-7},
series = {Schriften des Forschungszentrums Jülich Reihe Energie $\&$
Umwelt / Energy $\&$ Environment},
pages = {99 pp},
year = {2014},
note = {RWTH Aachen, Diss., 2013},
abstract = {The mechanical properties and reliability aspects of
advanced transparent fineandcoarse-grained MgAl$_{2}$O$_[4}$
spinel have been characterized at ambient and
hightemperature. The studies were based on a combination of
micro- and macro-mechanicalmethods to assess Young’s
modulus, hardness, fracture toughness, strength and
crackgrowth kinetics. The results and reliability aspects
are discussed in terms of linear elasticfracture mechanics.
Strength was analyzed using two- and three-parameter
Weibullstatistics. The experimental limits of Young’s
modulus determination using standard ringon-ring testing are
highlighted, and an approach is outlined to correct the
measuredapparent values. Experimentally obtained strength
data as a function of loading rate areused to assess the
potential effect of subcritical crack growth, yielding the
failure timeunder static loading, via a
strength/probability/time plot for a lifetime
prediction.Furthermore, the Brinell indentation showed
potential for local strength measurement and the data
supported a strength-loaded area relationship that was based
on the ring-on-ringtest data. Novel experimental methods
were implemented for fracture determination andstrain
detection. Particular attention was directed to the effect
of defects and associatedlocal strain fields, as assessed
using polarized light in photoelastic measurements.
Complementary fractography by optical, confocal and scanning
electron microscopy provided a correlation between failure
initiating defect size and fracture stress.},
keywords = {Dissertation (GND)},
cin = {IEK-2},
cid = {I:(DE-Juel1)IEK-2-20101013},
pnm = {122 - Power Plants (POF2-122)},
pid = {G:(DE-HGF)POF2-122},
typ = {PUB:(DE-HGF)11},
url = {https://juser.fz-juelich.de/record/133740},
}