@TECHREPORT{Fabbri:134818,
author = {Fabbri, Riccardo and Engels, Ralf W.},
title = {{P}reliminary {I}nvestigation of a {W}aveform {A}nalysis
with the {WASA} and the {ACQIRIS} {R}eadout {E}lectronics},
reportid = {FZJ-2013-02893},
pages = {36 pag.},
year = {2013},
abstract = {The Group for the development of neutron and gamma
detectors inthe Central Institute of Engineering,
Electronics and Analytics (ZEA-2)at Forschungszentrum
Jülich (FZJ) is developing a fast Anger Cameraprototype for
improving the rejection of the gamma contamination during
thedetection of neutrons. The prototype is based on a
scintillating plate forneutron capture and on the subsequent
generation of scintillating light collectedby a matrix of
4x4 vacuum Photomultipliers R268 by Hamamatsu.According to
the impinging point position of the incoming neutrons
thelight is collected by different PMTs, and via dedicated
algorithms the xand y coordinates can be calculated. In this
note theWASA and ACQIRISreadout electronics are compared
while performing a waveform analysisof the signals generated
by using both an analogue pulse generator andan LED+PMT
system. Different options of pre-amplifiers and
amplifiersare considered, and the results are here presented
and commented. Atthis stage of the prototype development,
systematical studies were notperformed while the scope of
this work was only to validate the principleof operations by
using both readout systems.},
cin = {ZEA-2},
cid = {I:(DE-Juel1)ZEA-2-20090406},
pnm = {542 - Neutrons (POF2-542)},
pid = {G:(DE-HGF)POF2-542},
typ = {PUB:(DE-HGF)15},
eprint = {1306.6889},
howpublished = {arXiv:1306.6889},
archivePrefix = {arXiv},
SLACcitation = {$\%\%CITATION$ = $arXiv:1306.6889;\%\%$},
url = {https://juser.fz-juelich.de/record/134818},
}