001     135068
005     20250129092431.0
024 7 _ |a 10.1088/0957-0233/24/8/085005
|2 doi
024 7 _ |a 1361-6501
|2 ISSN
024 7 _ |a 0957-0233
|2 ISSN
024 7 _ |a WOS:000321943100014
|2 WOS
037 _ _ |a FZJ-2013-03056
041 _ _ |a English
082 _ _ |a 600
100 1 _ |a Zhao, Y
|0 P:(DE-Juel1)143969
|b 0
|u fzj
|e Corresponding author
245 _ _ |a Broadband EIT borehole measurements with high phase accuracy using numerical corrections of electromagnetic coupling effects
260 _ _ |a Bristol
|c 2013
|b IOP Publ.
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1384336710_23682
|2 PUB:(DE-HGF)
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|0 0
|2 EndNote
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a article
|2 DRIVER
500 _ _ |3 POF3_Assignment on 2016-02-29
520 _ _ |a Electrical impedance tomography (EIT) is gaining importance in the field of geophysics and there is increasing interest for accurate borehole EIT measurements in a broad frequency range (mHz to kHz) in order to study subsurface properties. To characterize weakly polarizable soils and sediments with EIT, high phase accuracy is required. Typically, long electrode cables are used for borehole measurements. However, this may lead to undesired electromagnetic coupling effects associated with inductive coupling between the double wire pairs for current injection and potential measurement and capacitive coupling between the electrically conductive shield of the cable and the electrically conductive environment surrounding the electrode cables. Depending on the electrical properties of the subsurface and the measured transfer impedances, both coupling effects can cause large phase errors that have typically limited the frequency bandwidth of field EIT measurements to the mHz to Hz range. The aim of this paper is to develop numerical corrections for these phase errors. To this end, the inductive coupling effect was modeled using electronic circuit models and the capacitive coupling effect was modeled by integrating discrete capacitances in the electrical forward model describing the EIT measurement process. The correction methods were successfully verified with measurements under controlled conditions in a water-filled rain barrel, where a high phase accuracy of 0.8 mrad in the frequency range up to 10 kHz was achieved. The corrections were also applied to field EIT measurements made using a 25 m long EIT borehole chain with 8 electrodes and an electrode separation of 1 m. The results of a 1D inversion of these measurements showed that the correction methods increased the measurement accuracy considerably. It was concluded that the proposed correction methods enlarge the bandwidth of the field EIT measurement system, and that accurate EIT measurements can now be made in the mHz to kHz frequency range. This increased accuracy in the kHz range will allow a more accurate field characterization of the complex electrical conductivity of soils and sediments, which may lead to improved estimation of saturated hydraulic conductivity from electrical properties. Although the correction methods have been developed for a custom-made EIT system, they also have potential to improve to the phase accuracy of EIT measurements made with commercial systems relying on multicore cables.
536 _ _ |a 246 - Modelling and Monitoring Terrestrial Systems: Methods and Technologies (POF2-246)
|0 G:(DE-HGF)POF2-246
|c POF2-246
|x 0
|f POF II
588 _ _ |a Dataset connected to CrossRef, juser.fz-juelich.de
700 1 _ |a Zimmermann, Egon
|0 P:(DE-Juel1)133962
|b 1
700 1 _ |a Huisman, J A
|0 P:(DE-Juel1)129472
|b 2
|u fzj
700 1 _ |a Treichel, A
|0 P:(DE-Juel1)144273
|b 3
|u fzj
700 1 _ |a Wolters, Bernd
|0 P:(DE-Juel1)133958
|b 4
700 1 _ |a van Waasen, S
|0 P:(DE-Juel1)142562
|b 5
|u fzj
700 1 _ |a Kemna, A.
|0 P:(DE-HGF)0
|b 6
773 _ _ |a 10.1088/0957-0233/24/8/085005
|g Vol. 24, no. 8, p. 085005 -
|p 085005 -
|n 8
|0 PERI:(DE-600)1362523-8
|t Measurement science and technology
|v 24
|y 2013
|x 1361-6501
856 4 _ |u http://iopscience.iop.org/0957-0233/24/8/085005/
856 4 _ |u https://juser.fz-juelich.de/record/135068/files/FZJ-2013-03056.doc
|y Restricted
909 _ _ |p VDB
|o oai:juser.fz-juelich.de:135068
909 C O |o oai:juser.fz-juelich.de:135068
|p VDB
|p VDB:Earth_Environment
910 1 _ |a Zentralinstitut für Elektronik
|0 I:(DE-Juel1)ZEA-2-20090406
|k ZEA-2
|b 0
|6 P:(DE-Juel1)143969
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)143969
910 1 _ |a Zentralinstitut für Elektronik
|0 I:(DE-Juel1)ZEA-2-20090406
|k ZEA-2
|b 1
|6 P:(DE-Juel1)133962
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 1
|6 P:(DE-Juel1)133962
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)129472
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)144273
910 1 _ |a Zentralinstitut für Elektronik
|0 I:(DE-Juel1)ZEA-2-20090406
|k ZEA-2
|b 4
|6 P:(DE-Juel1)133958
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 4
|6 P:(DE-Juel1)133958
910 1 _ |a Zentralinstitut für Elektronik
|0 I:(DE-Juel1)ZEA-2-20090406
|k ZEA-2
|b 5
|6 P:(DE-Juel1)142562
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 5
|6 P:(DE-Juel1)142562
910 1 _ |a External Institute
|0 I:(DE-HGF)0
|k Extern
|b 6
|6 P:(DE-Juel1)VDB736
913 2 _ |a DE-HGF
|b Marine, Küsten- und Polare Systeme
|l Terrestrische Umwelt
|1 G:(DE-HGF)POF3-250
|0 G:(DE-HGF)POF3-259H
|2 G:(DE-HGF)POF3-200
|v Addenda
|x 0
913 1 _ |a DE-HGF
|b Erde und Umwelt
|l Terrestrische Umwelt
|1 G:(DE-HGF)POF2-240
|0 G:(DE-HGF)POF2-246
|2 G:(DE-HGF)POF2-200
|v Modelling and Monitoring Terrestrial Systems: Methods and Technologies
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF2
914 1 _ |y 2013
915 _ _ |a JCR/ISI refereed
|0 StatID:(DE-HGF)0010
|2 StatID
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
915 _ _ |a WoS
|0 StatID:(DE-HGF)0110
|2 StatID
|b Science Citation Index
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1050
|2 StatID
|b BIOSIS Previews
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)ZEA-2-20090406
|k ZEA-2
|l Zentralinstitut für Elektronik
|x 0
920 1 _ |0 I:(DE-Juel1)IBG-3-20101118
|k IBG-3
|l Agrosphäre
|x 1
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)ZEA-2-20090406
980 _ _ |a I:(DE-Juel1)IBG-3-20101118
981 _ _ |a I:(DE-Juel1)PGI-4-20110106
981 _ _ |a I:(DE-Juel1)IBG-3-20101118


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21