Home > Publications database > Kalorimetrische Gassensoren zur H2O2-Detektion in aseptischen Sterilisationsprozessen > print |
001 | 150590 | ||
005 | 20240619091111.0 | ||
024 | 7 | _ | |a 10.5162/11dss2013/B7 |2 doi |
037 | _ | _ | |a FZJ-2014-00639 |
041 | _ | _ | |a deu |
100 | 1 | _ | |a Oberländer, J. |0 P:(DE-HGF)0 |b 0 |e Corresponding author |
111 | 2 | _ | |a 11. Dresdner Sensor-Symposium |c Dresden |d 2013-12-09 - 2013-12-11 |w Germany |
245 | _ | _ | |a Kalorimetrische Gassensoren zur H2O2-Detektion in aseptischen Sterilisationsprozessen |
260 | _ | _ | |c 2013 |b AMA Service GmbH, P.O. Box 2352, 31506 Wunstorf, Germany |
300 | _ | _ | |a 234-238 |
336 | 7 | _ | |a Contribution to a conference proceedings |b contrib |m contrib |0 PUB:(DE-HGF)8 |s 1390566295_19358 |2 PUB:(DE-HGF) |
336 | 7 | _ | |a Conference Paper |0 33 |2 EndNote |
336 | 7 | _ | |a CONFERENCE_PAPER |2 ORCID |
336 | 7 | _ | |a Output Types/Conference Paper |2 DataCite |
336 | 7 | _ | |a conferenceObject |2 DRIVER |
336 | 7 | _ | |a INPROCEEDINGS |2 BibTeX |
500 | _ | _ | |3 POF3_Assignment on 2016-02-29 |
520 | _ | _ | |a In aseptisch arbeitenden Abfüllmaschinen, welche in der Lebensmittelindustrie und Pharmazie eingesetzt werden, hat sich, neben anderen chemischen Sterilisationsverfahren, Wasserstoffperoxid in der Gasphase als Sterilisationsmedium für Verpackungen etabliert. Die Sterilisation der Verpackungen ist notwendig, um eine mikrobiologische Kontamination der sterilen Produkte zu vermeiden. Um eine zeitnahe Evaluierung des Sterilisationsprozesses zu ermöglichen, wurden in den vergangen Jahren diverse Typen an kalorimetrischen Wasserstoffperoxid-Gassensoren entwickelt und hinsichtlich ihrerm Anforderungen optimiert. Hierbei wurden zwei verschiedene Methoden zur Erfassung der Reaktionsenthalpie des exothermen H2O2-Zerfalls als Maß der H2O2-Gaskonzentration verfolgt. Einerseits basierend auf einer Differenzanordnung, bestehend aus einem katalytisch aktiviertem und einem passiviertem Temperatur-sensitivem Widerstand und andererseits eine Differenzanordnung mittels Thermosäulen. |
536 | _ | _ | |a 423 - Sensorics and bioinspired systems (POF2-423) |0 G:(DE-HGF)POF2-423 |c POF2-423 |x 0 |f POF II |
536 | _ | _ | |a 453 - Physics of the Cell (POF2-453) |0 G:(DE-HGF)POF2-453 |c POF2-453 |x 1 |f POF II |
588 | _ | _ | |a Dataset connected to DataCite |
700 | 1 | _ | |a Reisert, S. |0 P:(DE-Juel1)128721 |b 1 |u fzj |
700 | 1 | _ | |a Kirchner, P. |0 P:(DE-Juel1)144221 |b 2 |u fzj |
700 | 1 | _ | |a Schöning, M. |0 P:(DE-Juel1)128727 |b 3 |u fzj |
700 | 1 | _ | |a Keusgen, M. |0 P:(DE-HGF)0 |b 4 |
700 | 1 | _ | |a Wagner, P. |0 P:(DE-HGF)0 |b 5 |
773 | _ | _ | |a 10.5162/11dss2013/B7 |
909 | C | O | |o oai:juser.fz-juelich.de:150590 |p VDB |
910 | 1 | _ | |a Forschungszentrum Jülich GmbH |0 I:(DE-588b)5008462-8 |k FZJ |b 1 |6 P:(DE-Juel1)128721 |
910 | 1 | _ | |a Forschungszentrum Jülich GmbH |0 I:(DE-588b)5008462-8 |k FZJ |b 2 |6 P:(DE-Juel1)144221 |
910 | 1 | _ | |a Forschungszentrum Jülich GmbH |0 I:(DE-588b)5008462-8 |k FZJ |b 3 |6 P:(DE-Juel1)128727 |
913 | 2 | _ | |a DE-HGF |b Key Technologies |l BioSoft – Fundamentals for future Technologies in the fields of Soft Matter and Life Sciences |1 G:(DE-HGF)POF3-550 |0 G:(DE-HGF)POF3-559H |2 G:(DE-HGF)POF3-500 |v Addenda |x 0 |
913 | 2 | _ | |a DE-HGF |b Key Technologies |l Future Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT) |1 G:(DE-HGF)POF3-520 |0 G:(DE-HGF)POF3-529H |2 G:(DE-HGF)POF3-500 |v Addenda |x 1 |
913 | 1 | _ | |a DE-HGF |b Schlüsseltechnologien |1 G:(DE-HGF)POF2-420 |0 G:(DE-HGF)POF2-423 |2 G:(DE-HGF)POF2-400 |v Sensorics and bioinspired systems |x 0 |4 G:(DE-HGF)POF |3 G:(DE-HGF)POF2 |l Grundlagen zukünftiger Informationstechnologien |
913 | 1 | _ | |a DE-HGF |b Schlüsseltechnologien |1 G:(DE-HGF)POF2-450 |0 G:(DE-HGF)POF2-453 |2 G:(DE-HGF)POF2-400 |v Physics of the Cell |x 1 |4 G:(DE-HGF)POF |3 G:(DE-HGF)POF2 |l BioSoft |
914 | 1 | _ | |y 2013 |
920 | 1 | _ | |0 I:(DE-Juel1)PGI-8-20110106 |k PGI-8 |l Bioelektronik |x 0 |
920 | 1 | _ | |0 I:(DE-82)080009_20140620 |k JARA-FIT |l JARA-FIT |x 1 |
920 | 1 | _ | |0 I:(DE-Juel1)ICS-8-20110106 |k ICS-8 |l Bioelektronik |x 2 |
980 | _ | _ | |a contrib |
980 | _ | _ | |a VDB |
980 | _ | _ | |a UNRESTRICTED |
980 | _ | _ | |a I:(DE-Juel1)PGI-8-20110106 |
980 | _ | _ | |a I:(DE-82)080009_20140620 |
980 | _ | _ | |a I:(DE-Juel1)ICS-8-20110106 |
981 | _ | _ | |a I:(DE-Juel1)IBI-3-20200312 |
981 | _ | _ | |a I:(DE-Juel1)ICS-8-20110106 |
Library | Collection | CLSMajor | CLSMinor | Language | Author |
---|