Hauptseite > Publikationsdatenbank > Observing proton motion on the nanoscale in polymeric electrolyte membranes with quasielastic neutron scattering > print |
001 | 172220 | ||
005 | 20240711101515.0 | ||
024 | 7 | _ | |2 doi |a 10.1016/j.ijhydene.2014.09.018 |
024 | 7 | _ | |2 ISSN |a 0360-3199 |
024 | 7 | _ | |2 ISSN |a 1879-3487 |
024 | 7 | _ | |2 WOS |a WOS:000347576200086 |
037 | _ | _ | |a FZJ-2014-05709 |
082 | _ | _ | |a 660 |
100 | 1 | _ | |0 P:(DE-Juel1)130718 |a Holderer, O. |b 0 |e Corresponding Author |u fzj |
245 | _ | _ | |a Observing proton motion on the nanoscale in polymeric electrolyte membranes with quasielastic neutron scattering |
260 | _ | _ | |a New York, NY [u.a.] |b Elsevier |c 2014 |
336 | 7 | _ | |0 PUB:(DE-HGF)16 |2 PUB:(DE-HGF) |a Journal Article |b journal |m journal |s 1422428326_8065 |
336 | 7 | _ | |2 DataCite |a Output Types/Journal article |
336 | 7 | _ | |0 0 |2 EndNote |a Journal Article |
336 | 7 | _ | |2 BibTeX |a ARTICLE |
336 | 7 | _ | |2 ORCID |a JOURNAL_ARTICLE |
336 | 7 | _ | |2 DRIVER |a article |
520 | _ | _ | |a The mechanism of proton conductivity in high temperature polymer electrolyte fuel cells (HT-PEFCs) has been investigated with macroscopic conductivity measurements and on a microscopic scale with quasielastic neutron scattering techniques. Polybenzimidazole membranes, which are used in HT-PEFCs, are doped with phosphoric acid (PA) to achieve the desired proton conductivity. Neutron spin echo experiments showed that the polymer matrix is very rigid incoherent scattering experiments, but incoherent scattering revealed rather fast diffusion processes, compatible with macroscopic conductivity measurements. The measured diffusion is faster than anticipated from the conductivity of a phosphoric acid doped PBI membrane, but slower than that expected for pure phosphoric acid. Over larger distances the fractal polymer membrane network slows down the locally fast diffusion to the macroscopic values. With elastic fixed window scans on a backscattering spectrometer an activation energy of 7.6 kJ/mol is obtained at typical conditions in an HT-PEFC. |
536 | _ | _ | |0 G:(DE-HGF)POF2-54G24 |a 54G - JCNS (POF2-54G24) |c POF2-54G24 |f POF II |x 0 |
536 | _ | _ | |0 G:(DE-HGF)POF2-451 |a 451 - Soft Matter Composites (POF2-451) |c POF2-451 |f POF II |x 1 |
588 | _ | _ | |a Dataset connected to CrossRef, juser.fz-juelich.de |
650 | 1 | 7 | |0 V:(DE-MLZ)GC-110 |2 V:(DE-HGF) |a Energy |x 0 |
650 | 2 | 7 | |0 V:(DE-MLZ)SciArea-180 |2 V:(DE-HGF) |a Materials Science |x 0 |
650 | 2 | 7 | |0 V:(DE-MLZ)SciArea-210 |2 V:(DE-HGF) |a Soft Condensed Matter |x 1 |
693 | _ | _ | |0 EXP:(DE-MLZ)SPHERES-20140101 |1 EXP:(DE-MLZ)FRMII-20140101 |5 EXP:(DE-MLZ)SPHERES-20140101 |6 EXP:(DE-MLZ)NL6S-20140101 |a Forschungs-Neutronenquelle Heinz Maier-Leibnitz |e SPHERES: Backscattering spectrometer |f NL6S |x 0 |
693 | _ | _ | |0 EXP:(DE-MLZ)J-NSE-20140101 |1 EXP:(DE-MLZ)FRMII-20140101 |5 EXP:(DE-MLZ)J-NSE-20140101 |6 EXP:(DE-MLZ)NL2ao-20140101 |a Forschungs-Neutronenquelle Heinz Maier-Leibnitz |e J-NSE: Neutron spin-echo spectrometer |f NL2ao |x 1 |
700 | 1 | _ | |0 P:(DE-Juel1)136923 |a Ivanova, O. |b 1 |u fzj |
700 | 1 | _ | |0 P:(DE-Juel1)145557 |a Hopfenmüller, B. |b 2 |u fzj |
700 | 1 | _ | |0 P:(DE-Juel1)131056 |a Zamponi, M. |b 3 |u fzj |
700 | 1 | _ | |0 P:(DE-Juel1)128533 |a Maier, W. |b 4 |u fzj |
700 | 1 | _ | |0 P:(DE-Juel1)143790 |a Majerus, Anne |b 5 |
700 | 1 | _ | |0 P:(DE-Juel1)129883 |a Lehnert, W. |b 6 |u fzj |
700 | 1 | _ | |0 P:(DE-Juel1)130849 |a Monkenbusch, M. |b 7 |u fzj |
700 | 1 | _ | |0 P:(DE-Juel1)131067 |a Zorn, R. |b 8 |u fzj |
773 | _ | _ | |0 PERI:(DE-600)1484487-4 |a 10.1016/j.ijhydene.2014.09.018 |g p. S0360319914025397 |n 36 |p 21657–21662 |t International journal of hydrogen energy |v 39 |x 0360-3199 |y 2014 |
856 | 4 | _ | |u https://juser.fz-juelich.de/record/172220/files/FZJ-2014-05709.pdf |y Restricted |
909 | C | O | |o oai:juser.fz-juelich.de:172220 |p VDB:MLZ |p VDB |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)130718 |a Forschungszentrum Jülich GmbH |b 0 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)136923 |a Forschungszentrum Jülich GmbH |b 1 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)145557 |a Forschungszentrum Jülich GmbH |b 2 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)131056 |a Forschungszentrum Jülich GmbH |b 3 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)128533 |a Forschungszentrum Jülich GmbH |b 4 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)143790 |a Forschungszentrum Jülich GmbH |b 5 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)129883 |a Forschungszentrum Jülich GmbH |b 6 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)130849 |a Forschungszentrum Jülich GmbH |b 7 |k FZJ |
910 | 1 | _ | |0 I:(DE-588b)5008462-8 |6 P:(DE-Juel1)131067 |a Forschungszentrum Jülich GmbH |b 8 |k FZJ |
913 | 2 | _ | |0 G:(DE-HGF)POF3-623 |1 G:(DE-HGF)POF3-620 |2 G:(DE-HGF)POF3-600 |9 G:(DE-HGF)POF3-6G4 |a DE-HGF |b Forschungsbereich Materie |l Von Materie zu Materialien und Leben |v Facility topic: Neutrons for Research on Condensed Matter |x 0 |
913 | 2 | _ | |0 G:(DE-HGF)POF3-621 |1 G:(DE-HGF)POF3-620 |2 G:(DE-HGF)POF3-600 |9 G:(DE-HGF)POF3-6215 |a DE-HGF |b Forschungsbereich Materie |l Von Materie zu Materialien und Leben |v In-house research on the structure, dynamics and function of matter |x 1 |
913 | 2 | _ | |0 G:(DE-HGF)POF3-600 |1 G:(DE-HGF)POF3 |2 G:(DE-HGF)POF |9 G:(DE-HGF)POF3-6G15 |a DE-HGF |b Programmorientierte Förderung |l POF III |v Forschungsbereich Materie |x 2 |
913 | 1 | _ | |0 G:(DE-HGF)POF2-54G24 |1 G:(DE-HGF)POF2-540 |2 G:(DE-HGF)POF2-500 |a DE-HGF |b Struktur der Materie |v JCNS |x 0 |4 G:(DE-HGF)POF |3 G:(DE-HGF)POF2 |l Forschung mit Photonen, Neutronen, Ionen |
913 | 1 | _ | |0 G:(DE-HGF)POF2-451 |1 G:(DE-HGF)POF2-450 |2 G:(DE-HGF)POF2-400 |a DE-HGF |b Schlüsseltechnologien |v Soft Matter Composites |x 1 |4 G:(DE-HGF)POF |3 G:(DE-HGF)POF2 |l BioSoft |
914 | 1 | _ | |y 2014 |
915 | _ | _ | |0 StatID:(DE-HGF)0100 |2 StatID |a JCR |
915 | _ | _ | |0 StatID:(DE-HGF)0110 |2 StatID |a WoS |b Science Citation Index |
915 | _ | _ | |0 StatID:(DE-HGF)0111 |2 StatID |a WoS |b Science Citation Index Expanded |
915 | _ | _ | |0 StatID:(DE-HGF)0150 |2 StatID |a DBCoverage |b Web of Science Core Collection |
915 | _ | _ | |0 StatID:(DE-HGF)0199 |2 StatID |a DBCoverage |b Thomson Reuters Master Journal List |
915 | _ | _ | |0 StatID:(DE-HGF)0200 |2 StatID |a DBCoverage |b SCOPUS |
915 | _ | _ | |0 StatID:(DE-HGF)0300 |2 StatID |a DBCoverage |b Medline |
915 | _ | _ | |0 StatID:(DE-HGF)0310 |2 StatID |a DBCoverage |b NCBI Molecular Biology Database |
915 | _ | _ | |0 StatID:(DE-HGF)1160 |2 StatID |a DBCoverage |b Current Contents - Engineering, Computing and Technology |
915 | _ | _ | |0 StatID:(DE-HGF)9900 |2 StatID |a IF < 5 |
920 | 1 | _ | |0 I:(DE-Juel1)JCNS-1-20110106 |k Neutronenstreuung ; JCNS-1 |l Neutronenstreuung |x 0 |
920 | 1 | _ | |0 I:(DE-Juel1)IEK-3-20101013 |k IEK-3 |l Elektrochemische Verfahrenstechnik |x 1 |
920 | 1 | _ | |0 I:(DE-Juel1)JCNS-FRM-II-20110218 |k JCNS (München) ; Jülich Centre for Neutron Science JCNS (München) ; JCNS-FRM-II |l JCNS-FRM-II |x 2 |
920 | 1 | _ | |0 I:(DE-Juel1)ICS-1-20110106 |k ICS-1 |l Neutronenstreuung |x 3 |
980 | _ | _ | |a journal |
980 | _ | _ | |a VDB |
980 | _ | _ | |a I:(DE-Juel1)JCNS-1-20110106 |
980 | _ | _ | |a I:(DE-Juel1)IEK-3-20101013 |
980 | _ | _ | |a I:(DE-Juel1)JCNS-FRM-II-20110218 |
980 | _ | _ | |a I:(DE-Juel1)ICS-1-20110106 |
980 | _ | _ | |a UNRESTRICTED |
981 | _ | _ | |a I:(DE-Juel1)ICE-2-20101013 |
981 | _ | _ | |a I:(DE-Juel1)IBI-8-20200312 |
981 | _ | _ | |a I:(DE-Juel1)JCNS-1-20110106 |
981 | _ | _ | |a I:(DE-Juel1)IEK-3-20101013 |
981 | _ | _ | |a I:(DE-Juel1)JCNS-FRM-II-20110218 |
981 | _ | _ | |a I:(DE-Juel1)ICS-1-20110106 |
Library | Collection | CLSMajor | CLSMinor | Language | Author |
---|