TI - Target development for diversified irradiations at a medical cyclotron
JO - Applied radiation and isotopes
VL - 104
SN - 0969-8043
CY - Amsterdam [u.a.]
PB - Elsevier Science
M1 - FZJ-2015-05087
SP - 106 - 112
PY - 2015
AB - The irradiation facility at an old medical cyclotron (Ep=17 MeV; Ed=10 MeV) was upgraded by extending the beam line and incorporation of solid state targetry. Tests performed to check the quality of the available beam are outlined. Results on nuclear data measurements and improvement of radiochemical separations are described. Using solid targets, with the proton beam falling at a slanting angle of 20°, a few radionuclides, e.g. 75Se, 120I, 124I, etc. were produced with medium currents (up to 20 µA) in no-carrier-added form in quantities sufficient for local use. The extended irradiation facility has considerably enhanced the utility of the medical cyclotron.Keywords: Medical cyclotron; Extended beam line; Solid state targetry; Nuclear data measurement; Activation of materials; Production of radionuclides