% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Mangiapia:255895,
      author       = {Mangiapia, Gaetano and Sartorio, Roberto and Lungu, Radu
                      P.},
      title        = {{P}lait point in ternary system with a miscibility gap:
                      {A}nalysis of the procedures involved in its determination
                      and development of novel procedures},
      journal      = {Fluid phase equilibria},
      volume       = {409},
      issn         = {0378-3812},
      address      = {New York, NY [u.a.]},
      publisher    = {Science Direct},
      reportid     = {FZJ-2015-05997},
      pages        = {49 - 58},
      year         = {2016},
      abstract     = {Ternary miscibility data, usually reported in the Roozeboom
                      triangular diagram, have been analyzed in Cartesian
                      coordinates defined by X = (xi − xj)/√3 and Y = xk where
                      xi, xj, and xk are the mole fractions of the two solvents
                      and of the solute, respectively. This has allowed for an
                      easy analytical representation of all the elements which are
                      characteristic of the system: binodal curve, tie lines,
                      plait point. Three novel methods for determining the plait
                      point composition have been proposed based only on its
                      fundamental properties. The results have been presented by
                      applying the methods to some systems described in the
                      literature. Differences between the values obtained with the
                      proposed methods and those obtainable with the NRTL and
                      UNIQUAC models have been found and are discussed.},
      cin          = {JCNS-FRM-II / Neutronenstreuung ; JCNS-1},
      ddc          = {660},
      cid          = {I:(DE-Juel1)JCNS-FRM-II-20110218 /
                      I:(DE-Juel1)JCNS-1-20110106},
      pnm          = {6215 - Soft Matter, Health and Life Sciences (POF3-621) /
                      6G15 - FRM II / MLZ (POF3-6G15) / 6G4 - Jülich Centre for
                      Neutron Research (JCNS) (POF3-623)},
      pid          = {G:(DE-HGF)POF3-6215 / G:(DE-HGF)POF3-6G15 /
                      G:(DE-HGF)POF3-6G4},
      experiment   = {EXP:(DE-MLZ)NOSPEC-20140101},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000367860400007},
      doi          = {10.1016/j.fluid.2015.09.017},
      url          = {https://juser.fz-juelich.de/record/255895},
}