@ARTICLE{Revay:256207,
      author       = {Revay, Zs. and Kudejova, P. and Kleszcz, K. and Söllradl,
                      S. and Genreith, Christoph},
      title        = {{I}n-beam activation analysis facility at {MLZ},
                      {G}arching},
      journal      = {Nuclear instruments $\&$ methods in physics research / A},
      volume       = {799},
      issn         = {0168-9002},
      address      = {Amsterdam},
      publisher    = {North-Holland Publ. Co.},
      reportid     = {FZJ-2015-06191},
      pages        = {114 - 123},
      year         = {2015},
      abstract     = {The reconstruction of the prompt gamma activation analysis
                      facility and the construction of the new low-background
                      counting chamber at MLZ, Garching is presented. The
                      improvement of the shielding and its effect on the radiation
                      background is shown. The setting up and the fine-tuning of
                      the electronics and their characterization are also
                      discussed. The upgraded facility has been demonstrated to be
                      applicable for both PGAA and neutron activation analysis
                      using in-beam activation and decay counting in the
                      low-background counting chamber.},