001     276448
005     20250701125923.0
024 7 _ |a 2128/9489
|2 Handle
037 _ _ |a FZJ-2015-06887
100 1 _ |a Schrader, Tobias Erich
|0 P:(DE-Juel1)138266
|b 0
|e Corresponding author
|u fzj
111 2 _ |a ECNS - European Conference on Neutron Scattering
|c Zaragoza
|d 2015-08-30 - 2015-09-04
|w Spain
245 _ _ |a BioDiff - a neutron diffractometer optimized for crystals with largeunit cell dimensions
260 _ _ |c 2015
336 7 _ |a Poster
|b poster
|m poster
|0 PUB:(DE-HGF)24
|s 1448897173_13521
|2 PUB:(DE-HGF)
336 7 _ |a Conference Paper
|0 33
|2 EndNote
336 7 _ |a Output Types/Conference Poster
|2 DataCite
336 7 _ |a conferenceObject
|2 DRIVER
336 7 _ |a CONFERENCE_POSTER
|2 ORCID
336 7 _ |a INPROCEEDINGS
|2 BibTeX
520 _ _ |a The newly built neutron single crystal diffractometer BIODIFF at the research reactor Heinz Maier-Leibnitz (FRM II) is especially designed to collect data from crystals with large unit cells. The main field of application is the structural analysis of proteins, especially the determination of hydrogen atom positions. BIODIFF is a joint project of the Jülich Centre for Neutron Science (JCNS) and the FRM II. Typical scientific questions addressed are the determination of protonation states of amino acid side chains and the characterization of the hydrogen bonding network between the protein active centre and an inhibitor or substrate. BIODIFF (see picture below) is designed as a monochromatic instrument with a narrow wavelength spread of less than 3 %. By using a highly orientated pyrolytic graphite monochromator (PG002) the diffractometer is able to change its central wavelength in the range between 2.4 Å and 5.6 Å. Contaminations of higher order wavelengths are removed by a neutron velocity selector. To cover a large solid angle the main detector of BIODIFF consists of a neutron imaging plate in a cylindrical geometry with online read-out capability. With a radius of 200 mm and a height of 450 mm it covers a solid angle of approximately 2π with a spatial resolution of up to 125 µm. A fast Li/ZnS scintillator CCD camera is available for additional detection abilities. An optical CCD-camera pointing at the sample position is used to quickly align the sample with respect to the neutron beam. The main advantage of BIODIFF is the possibility to adapt the wavelength to the size of the unit cell of the sample crystal while operating with a cleanmonochromatic beam that keeps the background level low. BIODFF is equipped with a standard Oxford Cryosystem “Cryostream 700+” which allows measurements in the temperature range from 90 K up to 500 K. A standard closed cycle cryostat is also available for measurements down to 4 K in vacuum. This may be used for the determination of magnetic unit cells of inorganic crystals in zero magnetic field. Recent applications of BIODIFF also include clay powder diffraction and diffraction from lipid membranes in a controlled humidity environment.
536 _ _ |a 6215 - Soft Matter, Health and Life Sciences (POF3-621)
|0 G:(DE-HGF)POF3-6215
|c POF3-621
|f POF III
|x 0
536 _ _ |0 G:(DE-HGF)POF3-6G15
|f POF III
|x 1
|c POF3-6G15
|a 6G15 - FRM II / MLZ (POF3-6G15)
536 _ _ |a 6G4 - Jülich Centre for Neutron Research (JCNS) (POF3-623)
|0 G:(DE-HGF)POF3-6G4
|c POF3-623
|f POF III
|x 2
650 2 7 |a Biology
|0 V:(DE-MLZ)SciArea-160
|2 V:(DE-HGF)
|x 0
650 1 7 |a Health and Life
|0 V:(DE-MLZ)GC-130-2016
|2 V:(DE-HGF)
|x 1
650 1 7 |a Health and Life
|0 V:(DE-MLZ)GC-130-1
|2 V:(DE-HGF)
|x 0
693 _ _ |a Forschungs-Neutronenquelle Heinz Maier-Leibnitz
|e BIODIFF: Diffractometer for large unit cells
|f NL1
|1 EXP:(DE-MLZ)FRMII-20140101
|0 EXP:(DE-MLZ)BIODIFF-20140101
|5 EXP:(DE-MLZ)BIODIFF-20140101
|6 EXP:(DE-MLZ)NL1-20140101
|x 0
700 1 _ |a Ostermann, Andreas
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Monkenbusch, Michael
|0 P:(DE-Juel1)130849
|b 2
|u fzj
700 1 _ |a Laatsch, Bernhard
|0 P:(DE-Juel1)133702
|b 3
|u fzj
700 1 _ |a Jüttner, Philipp
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Petry, Winfried
|0 P:(DE-HGF)0
|b 5
700 1 _ |a Richter, Dieter
|0 P:(DE-Juel1)130917
|b 6
|u fzj
856 4 _ |y OpenAccess
|u https://juser.fz-juelich.de/record/276448/files/ECNS_2015_Biodiff.pdf
856 4 _ |y OpenAccess
|x icon
|u https://juser.fz-juelich.de/record/276448/files/ECNS_2015_Biodiff.gif?subformat=icon
856 4 _ |y OpenAccess
|x icon-1440
|u https://juser.fz-juelich.de/record/276448/files/ECNS_2015_Biodiff.jpg?subformat=icon-1440
856 4 _ |y OpenAccess
|x icon-180
|u https://juser.fz-juelich.de/record/276448/files/ECNS_2015_Biodiff.jpg?subformat=icon-180
856 4 _ |y OpenAccess
|x icon-640
|u https://juser.fz-juelich.de/record/276448/files/ECNS_2015_Biodiff.jpg?subformat=icon-640
856 4 _ |y OpenAccess
|x pdfa
|u https://juser.fz-juelich.de/record/276448/files/ECNS_2015_Biodiff.pdf?subformat=pdfa
909 C O |o oai:juser.fz-juelich.de:276448
|p openaire
|p open_access
|p driver
|p VDB:MLZ
|p VDB
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 0
|6 P:(DE-Juel1)138266
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 2
|6 P:(DE-Juel1)130849
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 3
|6 P:(DE-Juel1)133702
910 1 _ |a Forschungszentrum Jülich GmbH
|0 I:(DE-588b)5008462-8
|k FZJ
|b 6
|6 P:(DE-Juel1)130917
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Von Materie zu Materialien und Leben
|1 G:(DE-HGF)POF3-620
|0 G:(DE-HGF)POF3-621
|2 G:(DE-HGF)POF3-600
|v In-house research on the structure, dynamics and function of matter
|9 G:(DE-HGF)POF3-6215
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
913 1 _ |a DE-HGF
|9 G:(DE-HGF)POF3-6G15
|x 1
|4 G:(DE-HGF)POF
|v FRM II / MLZ
|1 G:(DE-HGF)POF3-6G0
|0 G:(DE-HGF)POF3-6G15
|3 G:(DE-HGF)POF3
|2 G:(DE-HGF)POF3-600
|b Forschungsbereich Materie
|l Großgeräte: Materie
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Von Materie zu Materialien und Leben
|1 G:(DE-HGF)POF3-620
|0 G:(DE-HGF)POF3-623
|2 G:(DE-HGF)POF3-600
|v Facility topic: Neutrons for Research on Condensed Matter
|9 G:(DE-HGF)POF3-6G4
|x 2
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2015
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)JCNS-FRM-II-20110218
|k JCNS (München) ; Jülich Centre for Neutron Science JCNS (München) ; JCNS-FRM-II
|l JCNS-FRM-II
|x 0
920 1 _ |0 I:(DE-Juel1)JCNS-1-20110106
|k Neutronenstreuung ; JCNS-1
|l Neutronenstreuung
|x 1
920 1 _ |0 I:(DE-Juel1)ZEA-1-20090406
|k ZEA-1
|l Zentralinstitut für Technologie
|x 2
980 1 _ |a UNRESTRICTED
980 1 _ |a FullTexts
980 _ _ |a poster
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-Juel1)JCNS-FRM-II-20110218
980 _ _ |a I:(DE-Juel1)JCNS-1-20110106
980 _ _ |a I:(DE-Juel1)ZEA-1-20090406
981 _ _ |a I:(DE-Juel1)ITE-20250108
981 _ _ |a I:(DE-Juel1)ZEA-1-20090406


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21