000276578 001__ 276578
000276578 005__ 20220930130051.0
000276578 0247_ $$2doi$$a10.1109/JSEN.2015.2422894
000276578 0247_ $$2ISSN$$a1530-437X
000276578 0247_ $$2ISSN$$a1558-1748
000276578 0247_ $$2WOS$$aWOS:000357802000053
000276578 037__ $$aFZJ-2015-06943
000276578 041__ $$aEnglish
000276578 082__ $$a620
000276578 1001_ $$0P:(DE-Juel1)145906$$aBurkart, Andreas$$b0$$eCorresponding author
000276578 245__ $$aA Method for Uncertainty Assessment of Passive Sun-Induced Chlorophyll Fluorescence Retrieval Using an Infrared Reference Light
000276578 260__ $$aNew York, NY$$bIEEE$$c2015
000276578 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1450083967_20492
000276578 3367_ $$2DataCite$$aOutput Types/Journal article
000276578 3367_ $$00$$2EndNote$$aJournal Article
000276578 3367_ $$2BibTeX$$aARTICLE
000276578 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000276578 3367_ $$2DRIVER$$aarticle
000276578 520__ $$aMeasurements of sun-induced chlorophyll fluorescence (SIF) over plant canopies provide a proxy for plant photosynthetic capacity and are of high interest for plant research. Together with spectral reflectance, SIF has the potential to act as a noninvasive approach to quantify photosynthetic plant traits from field to air and spaceborne scales. However, SIF is a small signal contribution to the reflected sunlight and often not distinguishable from sensor noise. SIF estimation is, therefore, affected by an unquantified uncertainty, making it difficult to estimate accurately how much SIF is truly emitted from the plant. To investigate and overcome this, we designed a device based on a spectrometer covering the visible range and equipped it with an LED emitting at the wavelength of SIF. Using this as a reference and applying thorough calibrations, we present consistent evidence of the instrument's capability of SIF retrieval and accuracy estimations. The LED's intensity was measured under sunlight with 1.27 ± 0.27 mW × sr-1m-2nm-1 stable over the day. The large increase of SIF due to the Kautsky effect was measured spectrally and temporally proving the biophysical origin of the signal. We propose rigorous tests for instruments intended to measure SIF and show ways to further improve the presented methods.
000276578 536__ $$0G:(DE-HGF)POF3-582$$a582 - Plant Science (POF3-582)$$cPOF3-582$$fPOF III$$x0
000276578 588__ $$aDataset connected to CrossRef
000276578 7001_ $$0P:(DE-Juel1)7338$$aSchickling, Anke$$b1
000276578 7001_ $$0P:(DE-HGF)0$$aMateo, Maria Pilar Cendrero$$b2
000276578 7001_ $$0P:(DE-HGF)0$$aWrobel, Thomas Jan$$b3
000276578 7001_ $$0P:(DE-HGF)0$$aRossini, Micol$$b4
000276578 7001_ $$0P:(DE-HGF)0$$aCogliati, Sergio$$b5
000276578 7001_ $$0P:(DE-HGF)0$$aJulitta, Tommaso$$b6
000276578 7001_ $$0P:(DE-Juel1)129388$$aRascher, Uwe$$b7
000276578 773__ $$0PERI:(DE-600)2052059-1$$a10.1109/JSEN.2015.2422894$$gVol. 15, no. 8, p. 4603 - 4611$$n8$$p4603 - 4611$$tIEEE sensors journal$$v15$$x1558-1748$$y2015
000276578 8564_ $$uhttps://juser.fz-juelich.de/record/276578/files/07086007.pdf$$yRestricted
000276578 8564_ $$uhttps://juser.fz-juelich.de/record/276578/files/07086007.gif?subformat=icon$$xicon$$yRestricted
000276578 8564_ $$uhttps://juser.fz-juelich.de/record/276578/files/07086007.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000276578 8564_ $$uhttps://juser.fz-juelich.de/record/276578/files/07086007.jpg?subformat=icon-180$$xicon-180$$yRestricted
000276578 8564_ $$uhttps://juser.fz-juelich.de/record/276578/files/07086007.jpg?subformat=icon-640$$xicon-640$$yRestricted
000276578 8564_ $$uhttps://juser.fz-juelich.de/record/276578/files/07086007.pdf?subformat=pdfa$$xpdfa$$yRestricted
000276578 8767_ $$92015-06-09$$d2015-06-09$$eOther$$jZahlung erfolgt$$zFreight Charge: 68 $
000276578 8767_ $$92015-06-09$$d2015-06-09$$eOther$$jZahlung erfolgt$$zOverlength: 175 $
000276578 909CO $$ooai:juser.fz-juelich.de:276578$$pOpenAPC$$pVDB$$popenCost
000276578 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)145906$$aForschungszentrum Jülich GmbH$$b0$$kFZJ
000276578 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)7338$$aForschungszentrum Jülich GmbH$$b1$$kFZJ
000276578 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-HGF)0$$aForschungszentrum Jülich GmbH$$b2$$kFZJ
000276578 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)129388$$aForschungszentrum Jülich GmbH$$b7$$kFZJ
000276578 9131_ $$0G:(DE-HGF)POF3-582$$1G:(DE-HGF)POF3-580$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lKey Technologies for the Bioeconomy$$vPlant Science$$x0
000276578 9141_ $$y2015
000276578 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bIEEE SENS J : 2014
000276578 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000276578 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000276578 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000276578 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000276578 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000276578 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology
000276578 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000276578 920__ $$lyes
000276578 9201_ $$0I:(DE-Juel1)IBG-2-20101118$$kIBG-2$$lPflanzenwissenschaften$$x0
000276578 980__ $$ajournal
000276578 980__ $$aVDB
000276578 980__ $$aI:(DE-Juel1)IBG-2-20101118
000276578 980__ $$aUNRESTRICTED
000276578 980__ $$aAPC