001     278747
005     20210129220933.0
024 7 _ |a 10.1002/polb.23743
|2 doi
024 7 _ |a 0022-3832
|2 ISSN
024 7 _ |a 0098-1273
|2 ISSN
024 7 _ |a 0449-2951
|2 ISSN
024 7 _ |a 0449-2978
|2 ISSN
024 7 _ |a 0887-6266
|2 ISSN
024 7 _ |a 1099-0488
|2 ISSN
024 7 _ |a 1542-6238
|2 ISSN
024 7 _ |a 1542-6246
|2 ISSN
024 7 _ |a 1542-9377
|2 ISSN
024 7 _ |a 1542-9385
|2 ISSN
024 7 _ |a WOS:000357287100003
|2 WOS
037 _ _ |a FZJ-2015-07014
082 _ _ |a 530
100 1 _ |a Habicht, Axel
|0 P:(DE-HGF)0
|b 0
245 _ _ |a Critical fluctuations and static inhomogeneities in polymer gel volume phase transitions
260 _ _ |a Bognor Regis [u.a.]
|c 2015
|b Wiley
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1449667813_32514
|2 PUB:(DE-HGF)
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|0 0
|2 EndNote
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a article
|2 DRIVER
520 _ _ |a Thermoresponsive polymer gels exhibit pronounced swelling and deswelling upon changes in temperature, accompanied by dynamic concentration fluctuations that have been interpreted as critical opalescence. These fluctuations span lengthscales similar to that of static structures in the gels, such as the gel polymer-network meshsize (1–10 nm) and static polymer-network crosslinking inhomogeneities (10–1000 nm). To systematically investigate this overlay, we use droplet-based microfluidics and fabricate submillimeter-sized gel particles with varying static heterogeneity, as revealed on a molecular scale by proton NMR. When these microgels are probed by small-angle neutron scattering, the detection of dynamic fluctuations during the volume phase transitions is strongly perturbed by the co-existing static inhomogeneity. Depending of the type of data analysis employed, the temperature-dependent evolution of the correlation length associated to the dynamic fluctuations does or does not agree with predictions by the critical scaling theory. Only the most homogeneous sample of this study, prepared by controlled polymer crosslinking in droplet microfluidics, shows a diverging correlation length in agreement to the critical scaling theory independent of the specific approach of data analysis. These findings suggest that care must be taken about polymer-network heterogeneity when gel volume phase transitions are evaluated as critical phenomena.
536 _ _ |0 G:(DE-HGF)POF3-6G15
|f POF III
|x 0
|c POF3-6G15
|a 6G15 - FRM II / MLZ (POF3-6G15)
536 _ _ |a 6G4 - Jülich Centre for Neutron Research (JCNS) (POF3-623)
|0 G:(DE-HGF)POF3-6G4
|c POF3-623
|f POF III
|x 1
588 _ _ |a Dataset connected to CrossRef
650 2 7 |a Soft Condensed Matter
|0 V:(DE-MLZ)SciArea-210
|2 V:(DE-HGF)
|x 0
650 1 7 |a Earth, Environment and Cultural Heritage
|0 V:(DE-MLZ)GC-170-2016
|2 V:(DE-HGF)
|x 1
650 1 7 |a Earth, Environment and Cultural Heritage
|0 V:(DE-MLZ)GC-170
|2 V:(DE-HGF)
|x 0
693 _ _ |a Forschungs-Neutronenquelle Heinz Maier-Leibnitz
|e KWS-3: Very small angle scattering diffractometer with focusing mirror
|f NL3auS
|1 EXP:(DE-MLZ)FRMII-20140101
|0 EXP:(DE-MLZ)KWS3-20140101
|5 EXP:(DE-MLZ)KWS3-20140101
|6 EXP:(DE-MLZ)NL3auS-20140101
|x 0
700 1 _ |a Schmolke, Willi
|0 P:(DE-HGF)0
|b 1
700 1 _ |a Goerigk, Günter
|0 P:(DE-HGF)0
|b 2
700 1 _ |a Lange, Frank
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Saalwächter, Kay
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Ballauff, Matthias
|0 P:(DE-HGF)0
|b 5
700 1 _ |a Seiffert, Sebastian
|0 P:(DE-HGF)0
|b 6
|e Corresponding author
773 _ _ |a 10.1002/polb.23743
|g Vol. 53, no. 16, p. 1112 - 1122
|0 PERI:(DE-600)1473448-5
|n 16
|p 1112 - 1122
|t Journal of polymer science / B
|v 53
|y 2015
|x 0887-6266
856 4 _ |u https://juser.fz-juelich.de/record/278747/files/goerigk_Critical%20Fluctuations%20and%20Static%20Inhomogeneities%20in%20Polymer%20Gel%20Volume.pdf
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/278747/files/goerigk_Critical%20Fluctuations%20and%20Static%20Inhomogeneities%20in%20Polymer%20Gel%20Volume.gif?subformat=icon
|x icon
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/278747/files/goerigk_Critical%20Fluctuations%20and%20Static%20Inhomogeneities%20in%20Polymer%20Gel%20Volume.jpg?subformat=icon-1440
|x icon-1440
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/278747/files/goerigk_Critical%20Fluctuations%20and%20Static%20Inhomogeneities%20in%20Polymer%20Gel%20Volume.jpg?subformat=icon-180
|x icon-180
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/278747/files/goerigk_Critical%20Fluctuations%20and%20Static%20Inhomogeneities%20in%20Polymer%20Gel%20Volume.jpg?subformat=icon-640
|x icon-640
|y Restricted
856 4 _ |u https://juser.fz-juelich.de/record/278747/files/goerigk_Critical%20Fluctuations%20and%20Static%20Inhomogeneities%20in%20Polymer%20Gel%20Volume.pdf?subformat=pdfa
|x pdfa
|y Restricted
909 C O |o oai:juser.fz-juelich.de:278747
|p VDB:MLZ
|p VDB
913 1 _ |a DE-HGF
|9 G:(DE-HGF)POF3-6G15
|x 0
|4 G:(DE-HGF)POF
|v FRM II / MLZ
|1 G:(DE-HGF)POF3-6G0
|0 G:(DE-HGF)POF3-6G15
|3 G:(DE-HGF)POF3
|2 G:(DE-HGF)POF3-600
|b Forschungsbereich Materie
|l Großgeräte: Materie
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Von Materie zu Materialien und Leben
|1 G:(DE-HGF)POF3-620
|0 G:(DE-HGF)POF3-623
|2 G:(DE-HGF)POF3-600
|v Facility topic: Neutrons for Research on Condensed Matter
|9 G:(DE-HGF)POF3-6G4
|x 1
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2015
915 _ _ |a Nationallizenz
|0 StatID:(DE-HGF)0420
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b J POLYM SCI POL PHYS : 2014
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
915 _ _ |a WoS
|0 StatID:(DE-HGF)0110
|2 StatID
|b Science Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
920 _ _ |l yes
920 1 _ |0 I:(DE-Juel1)JCNS-FRM-II-20110218
|k JCNS (München) ; Jülich Centre for Neutron Science JCNS (München) ; JCNS-FRM-II
|l JCNS-FRM-II
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-Juel1)JCNS-FRM-II-20110218
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21