000280671 001__ 280671
000280671 005__ 20210129221400.0
000280671 0247_ $$2doi$$a10.1016/j.electacta.2015.07.184
000280671 0247_ $$2ISSN$$a0013-4686
000280671 0247_ $$2ISSN$$a1873-3859
000280671 0247_ $$2WOS$$aWOS:000365072400002
000280671 037__ $$aFZJ-2016-00428
000280671 041__ $$aEnglish
000280671 082__ $$a540
000280671 1001_ $$0P:(DE-HGF)0$$aMiyamoto, Ko-ichiro$$b0$$eCorresponding author
000280671 245__ $$aApplication of chemical imaging sensor to in-situ pH imaging in the vicinity of a corroding metal surface
000280671 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2015
000280671 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1453734202_6238
000280671 3367_ $$2DataCite$$aOutput Types/Journal article
000280671 3367_ $$00$$2EndNote$$aJournal Article
000280671 3367_ $$2BibTeX$$aARTICLE
000280671 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000280671 3367_ $$2DRIVER$$aarticle
000280671 520__ $$aThe chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.
000280671 536__ $$0G:(DE-HGF)POF3-523$$a523 - Controlling Configuration-Based Phenomena (POF3-523)$$cPOF3-523$$fPOF III$$x0
000280671 588__ $$aDataset connected to CrossRef
000280671 7001_ $$0P:(DE-HGF)0$$aSakakita, Sakura$$b1
000280671 7001_ $$0P:(DE-HGF)0$$aWagner, Torsten$$b2
000280671 7001_ $$0P:(DE-Juel1)128727$$aSchöning, Michael J.$$b3
000280671 7001_ $$0P:(DE-HGF)0$$aYoshinobu, Tatsuo$$b4
000280671 773__ $$0PERI:(DE-600)1483548-4$$a10.1016/j.electacta.2015.07.184$$gVol. 183, p. 137 - 142$$p137 - 142$$tElectrochimica acta$$v183$$x0013-4686$$y2015
000280671 8564_ $$uhttps://juser.fz-juelich.de/record/280671/files/1-s2.0-S0013468615302504-main.pdf$$yRestricted
000280671 8564_ $$uhttps://juser.fz-juelich.de/record/280671/files/1-s2.0-S0013468615302504-main.gif?subformat=icon$$xicon$$yRestricted
000280671 8564_ $$uhttps://juser.fz-juelich.de/record/280671/files/1-s2.0-S0013468615302504-main.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000280671 8564_ $$uhttps://juser.fz-juelich.de/record/280671/files/1-s2.0-S0013468615302504-main.jpg?subformat=icon-180$$xicon-180$$yRestricted
000280671 8564_ $$uhttps://juser.fz-juelich.de/record/280671/files/1-s2.0-S0013468615302504-main.jpg?subformat=icon-640$$xicon-640$$yRestricted
000280671 8564_ $$uhttps://juser.fz-juelich.de/record/280671/files/1-s2.0-S0013468615302504-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000280671 909CO $$ooai:juser.fz-juelich.de:280671$$pVDB
000280671 9101_ $$0I:(DE-588b)5008462-8$$6P:(DE-Juel1)128727$$aForschungszentrum Jülich GmbH$$b3$$kFZJ
000280671 9131_ $$0G:(DE-HGF)POF3-523$$1G:(DE-HGF)POF3-520$$2G:(DE-HGF)POF3-500$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bKey Technologies$$lFuture Information Technology - Fundamentals, Novel Concepts and Energy Efficiency (FIT)$$vControlling Configuration-Based Phenomena$$x0
000280671 9141_ $$y2015
000280671 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS
000280671 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bELECTROCHIM ACTA : 2014
000280671 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection
000280671 915__ $$0StatID:(DE-HGF)0110$$2StatID$$aWoS$$bScience Citation Index
000280671 915__ $$0StatID:(DE-HGF)0111$$2StatID$$aWoS$$bScience Citation Index Expanded
000280671 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5
000280671 915__ $$0StatID:(DE-HGF)0550$$2StatID$$aNo Authors Fulltext
000280671 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences
000280671 915__ $$0StatID:(DE-HGF)0310$$2StatID$$aDBCoverage$$bNCBI Molecular Biology Database
000280671 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline
000280671 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz
000280671 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bThomson Reuters Master Journal List
000280671 9201_ $$0I:(DE-Juel1)PGI-8-20110106$$kPGI-8$$lBioelektronik$$x0
000280671 980__ $$ajournal
000280671 980__ $$aVDB
000280671 980__ $$aUNRESTRICTED
000280671 980__ $$aI:(DE-Juel1)PGI-8-20110106