% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@INPROCEEDINGS{Reimers:283038,
author = {Reimers, Karl and Böhme, Christian and Gebel, Ralf and
Kamerdzhiev, Vsevolod and Conradie, Jacobus and Crombie,
Mogamad Amien and Mostert, Hendric},
title = {{U}pgrade of the {B}eam {P}rofile {M}onitoring {S}ystem in
the {I}njection {B}eam {L}ine of {COSY}},
school = {FZ Jülich},
reportid = {FZJ-2016-01720},
pages = {344-346},
year = {2015},
abstract = {The cyclotron Julic is used as an injector for the COSY
synchrotron and storage ring of 183 m circumference. The 93
m long injection beam line (IBL) transports polarized and
unpolarized H-/D- ions which are injected into the ring via
multi-turn stripping injection. 8 profile monitoring
stations are installed in the IBL. Each station contains two
harps having 39 wires at 1mm spacing. Each harp is read out
by a multichannel pico-amperemeter module designed by
iThemba LABS, South Africa, delivering profile data to the
COSY control system. The technical details of the upgrade
and recent beam profile measurements are presented.},
month = {Sep},
date = {2015-09-13},
organization = {IBIC 2015, Melbourne (Australia), 13
Sep 2015 - 17 Sep 2015},
subtyp = {Other},
cin = {IKP-4},
cid = {I:(DE-Juel1)IKP-4-20111104},
pnm = {631 - Accelerator R $\&$ D (POF3-631)},
pid = {G:(DE-HGF)POF3-631},
experiment = {EXP:(DE-MLZ)DEL-20140101},
typ = {PUB:(DE-HGF)8},
url = {https://juser.fz-juelich.de/record/283038},
}