000029423 245__ $$aICP-MS determination of trace elements in the serum samples of healthy subjects using different sample preparation methods
000029423 260__ $$aNorwalk, Conn.$$bPerkin-Elmer$$c2001
000029423 300__ $$a331- 335
000029423 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article
000029423 3367_ $$2DataCite$$aOutput Types/Journal article
000029423 3367_ $$00$$2EndNote$$aJournal Article
000029423 3367_ $$2BibTeX$$aARTICLE
000029423 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000029423 3367_ $$2DRIVER$$aarticle
000029423 440_0 $$0701$$aAtomic Spectroscopy$$v22$$x0195-5373
000029423 500__ $$aRecord converted from VDB: 12.11.2012
000029423 520__ $$aThe concentration of some trace elements of clinical importance was studied in blood serum samples of healthy subjects (n=19, mean age 22 +/- 4.5 years) to determine reference ranges for the healthy urban population in Eastern Hungary. A sample preparation method has been developed using closed-vessel microwave digestion with an oxidizing acid mixture (nitric acid and hydrogen peroxide) for multielemental analysis and atmospheric wet digestion with the aqueous solution of trimethyl amine (TMAH) for the measurement of aluminum. Contamination of the samples with Al was observed during acidic microwave digestion because of the chemicals used. Trace element concentrations in the samples were measured with ICP-TIS. The reference ranges obtained were (in mug/L): Al 0.98-1.74, Cr 42.8-59.3, Mn 2.27-5.05, Fe 1282-2050, Co 0.22-0.88, Ni 0.03-16.33, Cu 691-1003, Zn 591-1217, Sr 30.37-47.37, Mo 0.73-1.19, Cd 0.02-0.62, and Pb 0.02-2.70. The results were compared to the reference ranges actually used in the clinical practice, some of which are available in the literature. The effect of the applied digestion methods on the obtained individual results and average concentration ranges was also studied.
000029423 536__ $$0G:(DE-Juel1)FUEK118$$2G:(DE-HGF)$$aEntwicklung analytischer Verfahren$$c62.10.1$$x0
000029423 588__ $$aDataset connected to Web of Science
000029423 650_7 $$2WoSType$$aJ
000029423 7001_ $$0P:(DE-HGF)0$$aVarga, Z.$$b1
000029423 7001_ $$0P:(DE-Juel1)VDB2662$$aBecker, J. S.$$b2$$uFZJ
000029423 7001_ $$0P:(DE-HGF)0$$aMatyus, J.$$b3
000029423 7001_ $$0P:(DE-HGF)0$$aKakuk, G.$$b4
000029423 7001_ $$0P:(DE-HGF)0$$aPapp, L.$$b5
000029423 773__ $$0PERI:(DE-600)840758-7$$gVol. 22, p. 331- 335$$p331- 335$$q22<331- 335$$tAtomic spectroscopy$$v22$$x0195-5373$$y2001
000029423 909CO $$ooai:juser.fz-juelich.de:29423$$pVDB
000029423 9131_ $$0G:(DE-Juel1)FUEK118$$bEnergietechnik$$k62.10.1$$lWerkstoffe der Energietechnik$$vEntwicklung analytischer Verfahren$$x0
000029423 9141_ $$y2001
000029423 915__ $$0StatID:(DE-HGF)0010$$aJCR/ISI refereed
000029423 9201_ $$0I:(DE-Juel1)ZCH-20090406$$gZCH$$kZCH$$lZentralabteilung für Chemische Analysen$$x0
000029423 970__ $$aVDB:(DE-Juel1)2627
000029423 980__ $$aVDB
000029423 980__ $$aConvertedRecord
000029423 980__ $$ajournal
000029423 980__ $$aI:(DE-Juel1)ZEA-3-20090406
000029423 980__ $$aUNRESTRICTED
000029423 981__ $$aI:(DE-Juel1)ZEA-3-20090406
000029423 981__ $$aI:(DE-Juel1)ZCH-20090406