% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@PHDTHESIS{Wolfram:33332,
author = {Wolfram, Evelyn P.},
title = {{P}arallele {S}ubstratkontrolle in {B}ioreaktoren mit
geringem {V}olumen},
volume = {3982},
issn = {0944-2952},
school = {Techn. Univ. München},
type = {Dr. (Univ.)},
address = {Jülich},
publisher = {Forschungszentrum Jülich GmbH Zenralbibliothek, Verlag},
reportid = {PreJuSER-33332, Juel-3982},
series = {Berichte des Forschungszentrums Jülich},
pages = {VII, 194 p.},
year = {2002},
note = {Record converted from VDB: 12.11.2012; München, Techn.
Univ., Diss., 2001},
abstract = {In the first developmental phase of microbial processes,
relevant parameters for reaction engineering are
investigated and optimized with parallel experiments in
small reactors (shake flask scale) . Substrate
concentrations are central process parameters . Their
control might help to increase efficiency and quality of
this developmental phase . Thus, a parallel, automatic and
sterile sampling technique wich hollow fiber membranes was
developed that suits the Small reaction volume. The parallel
sampling modules were connected to a Substrate analysis
system. The combination of the analytical technique with a
controller and a precise microdosing System for Substrate
closed the control loop. The prototype device was
characterized and its suitability for online monitoring and
control of bioprocesses confirmed . This technique allows
for the firnt time online measurement and control of
Substrate concentrations in parallel bioreactions (i.e .
with Escherichia coli) wich measuring raten of the order of
minutes},
cin = {IBT-2},
cid = {I:(DE-Juel1)VDB56},
pnm = {Verfahrenstechnik zur mikrobiellen Gewinnung von
Primärmetaboliten},
pid = {G:(DE-Juel1)FUEK93},
typ = {PUB:(DE-HGF)11 / PUB:(DE-HGF)3},
url = {https://juser.fz-juelich.de/record/33332},
}