000040541 001__ 40541
000040541 005__ 20190625112126.0
000040541 0247_ $$2DOI$$a10.1016/S0013-4686(01)00564-3
000040541 0247_ $$2WOS$$aWOS:000171506400032
000040541 0247_ $$2altmetric$$aaltmetric:21812354
000040541 037__ $$aPreJuSER-40541
000040541 041__ $$aeng
000040541 082__ $$a540
000040541 084__ $$2WoS$$aElectrochemistry
000040541 1001_ $$0P:(DE-HGF)0$$aYoshinobu, T.$$b0
000040541 245__ $$aChemical imaging sensor and its application to biological systems
000040541 260__ $$aNew York, NY [u.a.]$$bElsevier$$c2001
000040541 300__ $$a259
000040541 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article
000040541 3367_ $$2DataCite$$aOutput Types/Journal article
000040541 3367_ $$00$$2EndNote$$aJournal Article
000040541 3367_ $$2BibTeX$$aARTICLE
000040541 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000040541 3367_ $$2DRIVER$$aarticle
000040541 440_0 $$01776$$aElectrochimica Acta$$v47$$x0013-4686
000040541 500__ $$aRecord converted from VDB: 12.11.2012
000040541 520__ $$aThe chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of chemical species in the specimen. One of the prospective applications of the chemical imaging sensor is the visualization of biochemical activities in biological systems. The chemical imaging sensor was successfully applied for the detection of Escherichia coli colonies. For further applications to biological systems, enhanced adhesion of the sample to the sensing surface seems to be indispensable. As a candidate material for biocompatible sensors, porous Si was tested and was found to have a high PH sensitivity of 57.3 mV/pH. (C) 2001 Elsevier Science Ltd. All rights reserved.
000040541 536__ $$0G:(DE-Juel1)FUEK66$$2G:(DE-HGF)$$aIonen- und Lithographietechnik$$c29.86.0$$x0
000040541 536__ $$0G:(DE-Juel1)FUEK69$$aHalbleiterschichtsysteme und Mesoskopische Strukturen$$c29.89.0$$x1
000040541 536__ $$0G:(DE-Juel1)FUEK68$$aHalbleiterbauelemente und Analytik$$c29.88.0$$x2
000040541 588__ $$aDataset connected to Web of Science
000040541 650_7 $$2WoSType$$aJ
000040541 65320 $$2Author$$achemical imaging sensor
000040541 65320 $$2Author$$alight-addressable potentiometric sensor
000040541 65320 $$2Author$$apH sensor
000040541 65320 $$2Author$$achemical sensor
000040541 65320 $$2Author$$ametabolism
000040541 7001_ $$0P:(DE-Juel1)VDB5501$$aEcken, H.$$b1$$uFZJ
000040541 7001_ $$0P:(DE-HGF)0$$aIsmail, A. B. M.$$b2
000040541 7001_ $$0P:(DE-HGF)0$$aIwasaki, H.$$b3
000040541 7001_ $$0P:(DE-Juel1)VDB975$$aLüth, H.$$b4$$uFZJ
000040541 7001_ $$0P:(DE-Juel1)128727$$aSchöning, M. J.$$b5$$uFZJ
000040541 773__ $$0PERI:(DE-600)1483548-4$$a10.1016/S0013-4686(01)00564-3$$gVol. 47, p. 259$$p259$$q47<259$$tElectrochimica acta$$v47$$x0013-4686$$y2001
000040541 909CO $$ooai:juser.fz-juelich.de:40541$$pVDB
000040541 9131_ $$0G:(DE-Juel1)FUEK66$$bInformationstechnik$$k29.86.0$$lGrundlagenforschung zur Informationstechnik$$vIonen- und Lithographietechnik$$x0
000040541 9131_ $$0G:(DE-Juel1)FUEK69$$bInformationstechnik$$k29.89.0$$lGrundlagenforschung zur Informationstechnik$$vHalbleiterschichtsysteme und Mesoskopische Strukturen$$x1
000040541 9131_ $$0G:(DE-Juel1)FUEK68$$bInformationstechnik$$k29.88.0$$lGrundlagenforschung zur Informationstechnik$$vHalbleiterbauelemente und Analytik$$x2
000040541 9141_ $$y2001
000040541 915__ $$0StatID:(DE-HGF)0010$$aJCR/ISI refereed
000040541 9201_ $$0I:(DE-Juel1)VDB41$$d31.12.2006$$gISG$$kISG-1$$lInstitut für Halbleiterschichten und Bauelemente$$x0
000040541 9201_ $$0I:(DE-Juel1)VDB42$$d31.12.2006$$gISG$$kISG-2$$lInstitut für Bio- und Chemosensoren$$x1
000040541 970__ $$aVDB:(DE-Juel1)5461
000040541 980__ $$aVDB
000040541 980__ $$aConvertedRecord
000040541 980__ $$ajournal
000040541 980__ $$aI:(DE-Juel1)PGI-9-20110106
000040541 980__ $$aI:(DE-Juel1)IBN-2-20090406
000040541 980__ $$aUNRESTRICTED
000040541 981__ $$aI:(DE-Juel1)PGI-9-20110106
000040541 981__ $$aI:(DE-Juel1)IBN-2-20090406