000040545 001__ 40545
000040545 005__ 20180210142150.0
000040545 0247_ $$2DOI$$a10.1002/1521-4109(200105)13:8/9<733::AID-ELAN733>3.0.CO;2-N
000040545 0247_ $$2WOS$$aWOS:000169443900020
000040545 037__ $$aPreJuSER-40545
000040545 041__ $$aeng
000040545 082__ $$a540
000040545 084__ $$2WoS$$aChemistry, Analytical
000040545 084__ $$2WoS$$aElectrochemistry
000040545 1001_ $$0P:(DE-HGF)0$$aYoshinobu, T.$$b0
000040545 245__ $$aConstant-current-mode LAPS (CLAPS) for the detection of penicillin
000040545 260__ $$aWeinheim$$b Wiley-VCH-Verl.$$c2001
000040545 300__ $$a733
000040545 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article
000040545 3367_ $$2DataCite$$aOutput Types/Journal article
000040545 3367_ $$00$$2EndNote$$aJournal Article
000040545 3367_ $$2BibTeX$$aARTICLE
000040545 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000040545 3367_ $$2DRIVER$$aarticle
000040545 440_0 $$01771$$aElectroanalysis$$v13$$x1040-0397$$y8-9
000040545 500__ $$aRecord converted from VDB: 12.11.2012
000040545 520__ $$aA software feedback control system for the constant-current-mode operation of the light-addressable potentiometric sensor (LAPS) was developed. The constant-current-mode LAPS (CLAPS) is suitable for online monitoring and recording of changes in the pH value or the ion concentration. An enzyme LAPS was fabricated by adsorptive immobilization of penicillinase on the pH-sensitive layer of Ta2O5 This sensor was operated in the constant-current-mode and the detection limit for penicillin G was found to be at least as low as 100 muM.
000040545 536__ $$0G:(DE-Juel1)FUEK66$$2G:(DE-HGF)$$aIonen- und Lithographietechnik$$c29.86.0$$x0
000040545 536__ $$0G:(DE-Juel1)FUEK69$$aHalbleiterschichtsysteme und Mesoskopische Strukturen$$c29.89.0$$x1
000040545 536__ $$0G:(DE-Juel1)FUEK68$$aHalbleiterbauelemente und Analytik$$c29.88.0$$x2
000040545 588__ $$aDataset connected to Web of Science
000040545 650_7 $$2WoSType$$aJ
000040545 65320 $$2Author$$alight-addressable potentiometric sensor (LAPS) CLAPS
000040545 65320 $$2Author$$achemical sensor
000040545 65320 $$2Author$$aTa2O5
000040545 65320 $$2Author$$apenicillin
000040545 7001_ $$0P:(DE-Juel1)VDB5501$$aEcken, H.$$b1$$uFZJ
000040545 7001_ $$0P:(DE-Juel1)VDB1267$$aPoghossian, A.$$b2$$uFZJ
000040545 7001_ $$0P:(DE-Juel1)VDB5469$$aSimonis, A.$$b3$$uFZJ
000040545 7001_ $$0P:(DE-HGF)0$$aIwasaki, H.$$b4
000040545 7001_ $$0P:(DE-Juel1)VDB975$$aLüth, H.$$b5$$uFZJ
000040545 7001_ $$0P:(DE-Juel1)128727$$aSchöning, M. J.$$b6$$uFZJ
000040545 773__ $$0PERI:(DE-600)1483564-2$$a10.1002/1521-4109(200105)13:8/9<733::AID-ELAN733>3.0.CO;2-N$$gVol. 13, p. 733$$p733$$q13<733$$tElectroanalysis$$v13$$x1040-0397$$y2001
000040545 909CO $$ooai:juser.fz-juelich.de:40545$$pVDB
000040545 9131_ $$0G:(DE-Juel1)FUEK66$$bInformationstechnik$$k29.86.0$$lGrundlagenforschung zur Informationstechnik$$vIonen- und Lithographietechnik$$x0
000040545 9131_ $$0G:(DE-Juel1)FUEK69$$bInformationstechnik$$k29.89.0$$lGrundlagenforschung zur Informationstechnik$$vHalbleiterschichtsysteme und Mesoskopische Strukturen$$x1
000040545 9131_ $$0G:(DE-Juel1)FUEK68$$bInformationstechnik$$k29.88.0$$lGrundlagenforschung zur Informationstechnik$$vHalbleiterbauelemente und Analytik$$x2
000040545 9141_ $$y2001
000040545 915__ $$0StatID:(DE-HGF)0010$$aJCR/ISI refereed
000040545 9201_ $$0I:(DE-Juel1)VDB41$$d31.12.2006$$gISG$$kISG-1$$lInstitut für Halbleiterschichten und Bauelemente$$x0
000040545 9201_ $$0I:(DE-Juel1)VDB42$$d31.12.2006$$gISG$$kISG-2$$lInstitut für Bio- und Chemosensoren$$x1
000040545 970__ $$aVDB:(DE-Juel1)5463
000040545 980__ $$aVDB
000040545 980__ $$aConvertedRecord
000040545 980__ $$ajournal
000040545 980__ $$aI:(DE-Juel1)PGI-9-20110106
000040545 980__ $$aI:(DE-Juel1)IBN-2-20090406
000040545 980__ $$aUNRESTRICTED
000040545 981__ $$aI:(DE-Juel1)PGI-9-20110106
000040545 981__ $$aI:(DE-Juel1)IBN-2-20090406