001     40545
005     20180210142150.0
024 7 _ |2 DOI
|a 10.1002/1521-4109(200105)13:8/9<733::AID-ELAN733>3.0.CO;2-N
024 7 _ |2 WOS
|a WOS:000169443900020
037 _ _ |a PreJuSER-40545
041 _ _ |a eng
082 _ _ |a 540
084 _ _ |2 WoS
|a Chemistry, Analytical
084 _ _ |2 WoS
|a Electrochemistry
100 1 _ |a Yoshinobu, T.
|0 P:(DE-HGF)0
|b 0
245 _ _ |a Constant-current-mode LAPS (CLAPS) for the detection of penicillin
260 _ _ |a Weinheim
|b Wiley-VCH-Verl.
|c 2001
300 _ _ |a 733
336 7 _ |a Journal Article
|0 PUB:(DE-HGF)16
|2 PUB:(DE-HGF)
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|0 0
|2 EndNote
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a article
|2 DRIVER
440 _ 0 |a Electroanalysis
|x 1040-0397
|0 1771
|y 8-9
|v 13
500 _ _ |a Record converted from VDB: 12.11.2012
520 _ _ |a A software feedback control system for the constant-current-mode operation of the light-addressable potentiometric sensor (LAPS) was developed. The constant-current-mode LAPS (CLAPS) is suitable for online monitoring and recording of changes in the pH value or the ion concentration. An enzyme LAPS was fabricated by adsorptive immobilization of penicillinase on the pH-sensitive layer of Ta2O5 This sensor was operated in the constant-current-mode and the detection limit for penicillin G was found to be at least as low as 100 muM.
536 _ _ |a Ionen- und Lithographietechnik
|c 29.86.0
|2 G:(DE-HGF)
|0 G:(DE-Juel1)FUEK66
|x 0
536 _ _ |a Halbleiterschichtsysteme und Mesoskopische Strukturen
|c 29.89.0
|0 G:(DE-Juel1)FUEK69
|x 1
536 _ _ |a Halbleiterbauelemente und Analytik
|c 29.88.0
|0 G:(DE-Juel1)FUEK68
|x 2
588 _ _ |a Dataset connected to Web of Science
650 _ 7 |a J
|2 WoSType
653 2 0 |2 Author
|a light-addressable potentiometric sensor (LAPS) CLAPS
653 2 0 |2 Author
|a chemical sensor
653 2 0 |2 Author
|a Ta2O5
653 2 0 |2 Author
|a penicillin
700 1 _ |a Ecken, H.
|0 P:(DE-Juel1)VDB5501
|b 1
|u FZJ
700 1 _ |a Poghossian, A.
|0 P:(DE-Juel1)VDB1267
|b 2
|u FZJ
700 1 _ |a Simonis, A.
|0 P:(DE-Juel1)VDB5469
|b 3
|u FZJ
700 1 _ |a Iwasaki, H.
|0 P:(DE-HGF)0
|b 4
700 1 _ |a Lüth, H.
|0 P:(DE-Juel1)VDB975
|b 5
|u FZJ
700 1 _ |a Schöning, M. J.
|0 P:(DE-Juel1)128727
|b 6
|u FZJ
773 _ _ |a 10.1002/1521-4109(200105)13:8/9<733::AID-ELAN733>3.0.CO;2-N
|g Vol. 13, p. 733
|p 733
|q 13<733
|0 PERI:(DE-600)1483564-2
|t Electroanalysis
|v 13
|y 2001
|x 1040-0397
909 C O |o oai:juser.fz-juelich.de:40545
|p VDB
913 1 _ |k 29.86.0
|v Ionen- und Lithographietechnik
|l Grundlagenforschung zur Informationstechnik
|b Informationstechnik
|0 G:(DE-Juel1)FUEK66
|x 0
913 1 _ |k 29.89.0
|v Halbleiterschichtsysteme und Mesoskopische Strukturen
|l Grundlagenforschung zur Informationstechnik
|b Informationstechnik
|0 G:(DE-Juel1)FUEK69
|x 1
913 1 _ |k 29.88.0
|v Halbleiterbauelemente und Analytik
|l Grundlagenforschung zur Informationstechnik
|b Informationstechnik
|0 G:(DE-Juel1)FUEK68
|x 2
914 1 _ |y 2001
915 _ _ |0 StatID:(DE-HGF)0010
|a JCR/ISI refereed
920 1 _ |k ISG-1
|l Institut für Halbleiterschichten und Bauelemente
|d 31.12.2006
|g ISG
|0 I:(DE-Juel1)VDB41
|x 0
920 1 _ |k ISG-2
|l Institut für Bio- und Chemosensoren
|d 31.12.2006
|g ISG
|0 I:(DE-Juel1)VDB42
|x 1
970 _ _ |a VDB:(DE-Juel1)5463
980 _ _ |a VDB
980 _ _ |a ConvertedRecord
980 _ _ |a journal
980 _ _ |a I:(DE-Juel1)PGI-9-20110106
980 _ _ |a I:(DE-Juel1)IBN-2-20090406
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)PGI-9-20110106
981 _ _ |a I:(DE-Juel1)IBN-2-20090406


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21