@ARTICLE{Udintsev:45846,
      author       = {Udintsev, V. S. and van de Pol, M. J. and Donne, A. J. H.
                      and Oosterbeek, J. W. and Krämer-Flecken, A.},
      title        = {{N}ew {ECE} diagnostics for the {TEXTOR}-94 tokamak},
      journal      = {Review of scientific instruments},
      volume       = {72},
      issn         = {0034-6748},
      address      = {[S.l.]},
      publisher    = {American Institute of Physics},
      reportid     = {PreJuSER-45846},
      pages        = {359 - 362},
      year         = {2001},
      note         = {Record converted from VDB: 12.11.2012},
      abstract     = {To aid the scientific research program on the Toroidal
                      Experiment for Technology Oriented Research (TEXTOR)-94
                      tokamak, the existing electron cyclotron emission (ECE)
                      diagnostics for the electron temperature studies are being
                      extended with new systems that feature a good temporal and
                      radial resolution. Using the possibility of obtaining the
                      data on a fast time scale, ECE systems allow one to study
                      fast phenomena like the dynamics of small-scale structures
                      such as magnetic islands and transport barriers and
                      microscopic temperature fluctuations throughout the plasma.
                      The quantitative information about nonthermal electron
                      populations can be obtained from the comparison of the
                      second and third harmonic emission. A new 16-channel
                      frequency tunable radiometer and a four-channel second
                      harmonic system were recently installed at TEXTOR-94. The
                      detailed description of the new TEXTOR-94 ECE systems and
                      the recent results will be given and discussed in this
                      article. (C) 2001 American Institute of Physics.},
      keywords     = {J (WoSType)},
      cin          = {IPP},
      ddc          = {530},
      cid          = {I:(DE-Juel1)VDB181},
      pnm          = {TEC-FOM / Instabilitäten und transportvorgänge im Plasma},
      pid          = {G:(DE-Juel1)FUEK201 / G:(DE-Juel1)FUEK45},
      shelfmark    = {Instruments $\&$ Instrumentation / Physics, Applied},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000166141600019},
      doi          = {10.1063/1.1309001},
      url          = {https://juser.fz-juelich.de/record/45846},
}