001     45897
005     20200610184746.0
024 7 _ |2 Handle
|a 2128/20626
037 _ _ |a PreJuSER-45897
088 1 _ |a Juel-3793
088 _ _ |a Juel-3793
|2 JUEL
100 1 _ |0 P:(DE-Juel1)VDB6686
|a Meurer, Hans Christoph
|b 0
|e Corresponding author
|u FZJ
245 _ _ |a Auslegung saisonaler Wasserstoffspeicher für die Energieversorgung aus Solarstrahlung, Windkraft und Umgebungswärme
260 _ _ |a Jülich
|b Forschungszentrum Jülich GmbH Zentralbibliothek, Verlag
300 _ _ |a 108 p.
336 7 _ |0 PUB:(DE-HGF)3
|2 PUB:(DE-HGF)
|a Book
336 7 _ |2 DRIVER
|a book
336 7 _ |0 1
|2 EndNote
|a Book
336 7 _ |2 DataCite
|a Output Types/Book
336 7 _ |2 ORCID
|a BOOK
336 7 _ |2 BibTeX
|a BOOK
490 0 _ |0 PERI:(DE-600)2414853-2
|8 1145
|a Berichte des Forschungszentrums Jülich
|v 3793
|x 0944-2952
500 _ _ |a Record converted from VDB: 12.11.2012
520 _ _ |a In the present study a design procedure for hydrogen storage systems in power plants with renewable energy is presented. The storage system eonsists of an electrolyzer, gas storage in high pressure tanks and reconversion into electricity by a fuel cell . This work is based an the experiences male by construction and operation of the demonstration plant PHOEBUS Jülich for Photovoltaik, Elektrolyse, Brennstoffzelle und Systemtechnik (photovoltaics, electrolysis, fuel cell and System engineering) at the Research Centre Jülich. These systems are treated by dynamic simulation in a high temporal resolution. The seasonal and the stochastical behaviour of the yield of renewable energy and energy consumption is taken into account by simulating over a time span of 17 years using measured meteorologieal data. For optimization the autarky-limit-procedure is introduced. A cost model is applied to the results of the simulation . The autarky-limit describes the correlation between the capacity of the installed gas tank and the rated power of the installed converters for renewable energy in case of exactly seif-sufficient plant operation . Using the autarky-Iimit procedure, it is possible to size all major components for long-term operation at minimal costs. The procedure is applied for a modelled consumer at Research Centre Jülich site . Various configurations of the storage system are investigated and compared . More generalized statements about a reasonable use of hydrogen storage are derived from the results .
536 _ _ |0 G:(DE-Juel1)FUEK26
|2 G:(DE-HGF)
|a Regenerative Energiesysteme
|c 11.60.0
|x 0
856 4 _ |u https://juser.fz-juelich.de/record/45897/files/J%C3%BCl_3793_Meurer.pdf
|y OpenAccess
856 4 _ |u https://juser.fz-juelich.de/record/45897/files/J%C3%BCl_3793_Meurer.pdf?subformat=pdfa
|x pdfa
|y OpenAccess
909 C O |o oai:juser.fz-juelich.de:45897
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
913 1 _ |0 G:(DE-Juel1)FUEK26
|b Energietechnik
|k 11.60.0
|l Energieumwandlungstechniken
|v Regenerative Energiesysteme
|x 0
914 1 _ |y 2000
915 _ _ |0 StatID:(DE-HGF)0510
|2 StatID
|a OpenAccess
920 1 _ |0 I:(DE-Juel1)VDB183
|d 31.12.2000
|g IWV
|k IWV
|l Institut für Werkstoffe und Verfahren der Energietechnik
|x 0
970 _ _ |a VDB:(DE-Juel1)7134
980 _ _ |a VDB
980 _ _ |a ConvertedRecord
980 _ _ |a book
980 _ _ |a I:(DE-Juel1)VDB183
980 _ _ |a UNRESTRICTED
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21