% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Bayerbach:46912,
author = {Bayerbach, R. and Nguyen, V. D. and Schurr, U. and Meier,
D.},
title = {{C}haracterization of the water-insoluble fraction from
fast pyrolysis liquids (pyrolytic lignin) part {III}.
{M}olar mass characteristics by {SEC}, {MALDI}-{TOF}/{MS},
{LDI}-{TOF}/{MS}, and {PY}-{FIMS}},
journal = {Journal of analytical and applied pyrolysis},
volume = {77},
issn = {0165-2370},
address = {New York, NY [u.a.]},
publisher = {Science Direct},
reportid = {PreJuSER-46912},
pages = {95 - 101},
year = {2006},
note = {Record converted from VDB: 12.11.2012},
abstract = {Matrix assisted laser desorption ionisation-time of
flight-mass spectrometry (MALDI-TOF-MS) laser desorption
ionisation-time of flight-mass spectrometry (LDI-TOF-MS) and
temperature resolved analytical pyrolysis field ionisation
mass spectrometry (Py-FIMS) have been applied for the first
time on two pyrolytic lignins (PL's), precipitated from
different aged bio oil, and four PL-fractions for molar mass
characterization. The results were compared with data from
size exclusion chromatography (SEC). SEC was the only method
that allowed a mathematical calculation of molar mass
characteristics such as average molecular weight (Mw),
dispersity (D), and the molar mass at the peak maximum of
the elugram (Mp). The SEC Mp values of PL-fractions differ
from visually interpolated MALDI-TOF-MS measurements by
$20\%.$ MALDI-TOF-MS spectra showed detailed structures of
the molar mass distribution (MMD) of PL and PL-fractions.
Especially, the spectrum of one PL showed various local
maxima with intervals of 170-200 Da. The size of these
intervals could represent the average absolute molar mass of
PL-monomers. MALDI-TOF-MS was limited by the influence of
superposing matrix signals in the spectrum at low molar
masses. LDI-TOF-MS showed clearer spectra than MALDI-TOF-MS
in mass ranges below 400 Da. No signals were obtained for
fractions with higher masses or whole PL. Intervals between
main signals were mostly 14-16 Da. In spectra of different
PL-fractions, corresponding main signals can vary between 2
and 4 Da. These mass differences indicate variations in the
aliphatic region of the PL molecules. Py-FIMS spectra
contained masses of thermally ejected, but unfragmented
monomers and dimers. It was the only method, which allowed
partial identification of monomeric and dimeric structures
of all samples. The detected monomers correspond to known
lignin derived compounds in bio oil, the detected dimers
have some similarities to phenylcoumaran structures. PL from
aged bio oil showed an increased content of higher oligomers
and a higher average molecular weight. (C) 2006 Elsevier
B.V. All rights reserved.},
keywords = {J (WoSType)},
cin = {ICG-III / JARA-ENERGY},
ddc = {660},
cid = {I:(DE-Juel1)VDB49 / $I:(DE-82)080011_20140620$},
pnm = {Terrestrische Umwelt},
pid = {G:(DE-Juel1)FUEK407},
shelfmark = {Chemistry, Analytical / Spectroscopy},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000241223100001},
doi = {10.1016/j.jaap.2006.02.002},
url = {https://juser.fz-juelich.de/record/46912},
}