001     57154
005     20180211164708.0
024 7 _ |2 DOI
|a 10.2136/sssaj2006.0106
024 7 _ |2 WOS
|a WOS:000243947100005
037 _ _ |a PreJuSER-57154
041 _ _ |a eng
082 _ _ |a 550
084 _ _ |2 WoS
|a Soil Science
100 1 _ |a Mertens, J.
|b 0
|0 P:(DE-HGF)0
245 _ _ |a Numerical analysis of passive capillary wick samplers prior to field installation
260 _ _ |a Madison, Wis.
|b SSSA
|c 2007
300 _ _ |a 35 - 42
336 7 _ |a Journal Article
|0 PUB:(DE-HGF)16
|2 PUB:(DE-HGF)
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|0 0
|2 EndNote
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a article
|2 DRIVER
440 _ 0 |a Soil Science Society of America Journal
|x 0361-5995
|0 8103
|v 71
500 _ _ |a Record converted from VDB: 12.11.2012
520 _ _ |a Accurately measuring water fluxes and associated nutrient or contaminant concentrations through the vadose zone is difficult because an appropriate suction needs to be exerted on the soil to sample water under unsaturated conditions. Passive capillary wick sampling systems are cheap and reliable instruments resulting in acceptable measurements of water fluxes in the vadose zone; however, their success in measuring realistic fluxes depends on their compatibility with the soil and climatic conditions in which they are installed. This study was developed in the preplanning phase of a field experiment with its main objective the monitoring of dissolved organic matter and the associated transfer of Cu2+ and pesticides through the vadose zone. We studied a combination of two-dimensional and axisymmetrical three-dimensional numerical analyses using the HYDRUS-2D software to identify what sampler geometry, wick type, wick length, and number of wicks are most suitable for the soil conditions at the experimental site. An AM3/8HI wick with seasonally varying wick length (40 cm in winter and 100 cm in summer) was found to be most appropriate for the soil and climatic conditions of the experimental field. The numerical analysis indicated that well-designed wick samplers had a negligible effect on the soil moisture content close to the sampler. A double-ring wick sampler is proposed to minimize the effect of the area between the installation pit or trench and the sampler. This approach is easily applicable and transferable to other soil and wick types and climatic conditions. The study emphasizes the suitability of numerical modeling to optimize experimental design before installation.
536 _ _ |a Terrestrische Umwelt
|c P24
|2 G:(DE-HGF)
|0 G:(DE-Juel1)FUEK407
|x 0
588 _ _ |a Dataset connected to Web of Science
650 _ 7 |a J
|2 WoSType
700 1 _ |a Diels, J.
|b 1
|0 P:(DE-HGF)0
700 1 _ |a Feyen, J.
|b 2
|0 P:(DE-HGF)0
700 1 _ |a Vanderborght, J.
|b 3
|u FZJ
|0 P:(DE-Juel1)129548
773 _ _ |a 10.2136/sssaj2006.0106
|g Vol. 71, p. 35 - 42
|p 35 - 42
|q 71<35 - 42
|0 PERI:(DE-600)1481691-x
|t Soil Science Society of America journal
|v 71
|y 2007
|x 0361-5995
856 7 _ |u http://dx.doi.org/10.2136/sssaj2006.0106
909 C O |o oai:juser.fz-juelich.de:57154
|p VDB
913 1 _ |k P24
|v Terrestrische Umwelt
|l Terrestrische Umwelt
|b Erde und Umwelt
|0 G:(DE-Juel1)FUEK407
|x 0
914 1 _ |y 2007
915 _ _ |0 StatID:(DE-HGF)0010
|a JCR/ISI refereed
920 1 _ |k ICG-4
|l Agrosphäre
|d 31.10.2010
|g ICG
|0 I:(DE-Juel1)VDB793
|x 1
970 _ _ |a VDB:(DE-Juel1)89908
980 _ _ |a VDB
980 _ _ |a ConvertedRecord
980 _ _ |a journal
980 _ _ |a I:(DE-Juel1)IBG-3-20101118
980 _ _ |a UNRESTRICTED
981 _ _ |a I:(DE-Juel1)IBG-3-20101118


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21